Files
Lifts the previous "one driver = one slave" assumption so a single Modbus driver instance can front N RTU slaves behind one Ethernet gateway (Anybus, ProSoft, Lantronix style). Each tag carries an optional UnitId that drives the MBAP unit-id byte per-PDU, and the IPerCallHostResolver contract surfaces per-slave host strings so per-PLC circuit breakers fire per-slave (matches the AB CIP template documented in docs/v2/multi-host-dispatch.md). Changes: - ModbusTagDefinition gains optional UnitId (byte?). Null = use driver-level ModbusDriverOptions.UnitId (preserves single-slave deployments verbatim). - ResolveUnitId(tag) helper computed once per ReadOneAsync / WriteOneAsync call; passed through ReadRegisterBlockAsync / ReadBitBlockAsync / ReadRegisterBlockChunkedAsync / ReadBitBlockChunkedAsync explicitly. The probe loop continues using driver-level UnitId (the probe is a connection-health check, not slave-specific). - ModbusDriver implements IPerCallHostResolver. ResolveHost(fullReference) returns "host:port/unitN" — distinct strings per slave so the resilience pipeline keys breakers on the right granularity. Unknown references fall back to the bare HostName (single-slave behaviour). - BitInRegister RMW path also threads the per-tag UnitId through both the read and write halves so a multi-slave deployment stays correct under bit- level writes. - Factory DTO + JSON binding extended with the per-tag UnitId field. Tests (4 new ModbusMultiUnitTests): - Per-tag UnitId routes to the correct slave in the MBAP header (driver-level UnitId=99 must NOT appear when both tags override). - Tag without override falls back to driver-level UnitId. - IPerCallHostResolver returns distinct "host:port/unitN" strings per slave. - Unknown reference returns the bare HostName fallback. Existing 220 unit tests + 107 addressing tests still green. Per-PLC breaker isolation under simulated dead slaves is verifiable via the existing AB CIP test infra; live coverage lands as an integration test in the #138 docs/e2e refresh.
Phase 3 PR 59 -- MelsecAddress helper for MELSEC X/Y hex-vs-octal family trap + D/M bank bases. Adds MelsecAddress static class with XInputToDiscrete, YOutputToCoil, MRelayToCoil, DRegisterToHolding helpers and a MelsecFamily enum {Q_L_iQR, F_iQF} that drives whether X/Y addresses are parsed as hex (Q-series convention) or octal (FX-series convention). This is the #1 MELSEC driver bug source per docs/v2/mitsubishi.md: the string 'X20' on a MELSEC-Q means DI 32 (hex 0x20) while the same string on an FX3U means DI 16 (octal 0o20). The helper forces the caller to name the family explicitly; no 'sensible default' because wrong defaults just move the bug. Key design decisions: (1) Family is an enum argument, not a helper-level static-selector, because real deployments have BOTH Q-series and FX-series PLCs on the same gateway -- one driver instance per device means family must be per-tag, not per-driver. (2) Bank base is a ushort argument defaulting to 0. Real QJ71MT91/LJ71MT91 assignment blocks commonly place X at DI 8192+, Y at coil 8192+, etc. to leave the low-address range for D-registers; the helper takes the site's configured base as runtime config rather than a compile-time constant. Matches the 'driver opt-in per tag' pattern DirectLogicAddress established for DL260. (3) M-relay and D-register are DECIMAL on every MELSEC family -- docs explicitly; the MELSEC confusion is only about X/Y, not about data registers or internal relays. Helpers reject non-numeric M/D addresses and honor bank bases the same way. (4) Parser walks digits manually for both hex and octal (instead of int.Parse with NumberStyles) so non-hex / non-octal characters give a clear ArgumentException with the offending char + family name. Prevents a subtle class of bugs where int.Parse('X20', Hex) silently returns 32 even for F_iQF callers. Unit tests (MelsecAddressTests, 34 facts): XInputToDiscrete_QLiQR_parses_hex theory (X0, X9, XA, XF, X10, X20, X1FF + lowercase); XInputToDiscrete_FiQF_parses_octal theory (X0, X7, X10, X20, X777); YOutputToCoil equivalents; Same_address_string_decodes_differently_between_families (the headline trap, X20 => 32 on Q vs 16 on FX); reject-non-octal / reject-non-hex / reject-empty / overflow facts; honors-bank-base for X and M and D. 176/176 Modbus.Tests pass (143 prior + 34 new Melsec). No driver core changes -- this is purely a new helper class in the Driver.Modbus project. PR 60 wires it into integration tests against the mitsubishi pymodbus profile.
RMW pass 1 — Modbus BitInRegister + FOCAS PMC Bit write paths. First half of task #181 — the two drivers where read-modify-write is a clean protocol-level insertion (Modbus FC03/FC06 round-trip + FOCAS pmc_rdpmcrng / pmc_wrpmcrng round-trip). Per-driver SemaphoreSlim registry keyed on the parent word address serialises concurrent bit writes so two writers targeting different bits in the same word don't lose one another's update. Modbus — ModbusDriver gains WriteBitInRegisterAsync + _rmwLocks ConcurrentDictionary. WriteOneAsync routes BitInRegister (HoldingRegisters region only) through RMW ahead of the normal encode path. Read uses FC03 Read Holding Registers for 1 register at tag.Address, bit-op on the returned ushort via (current | 1<<bit) for set / (current & ~(1<<bit)) for clear, write back via FC06 Write Single Register. Per-address lock prevents concurrent bit writes to the same register from racing. Rejects out-of-range bits (0-15) with InvalidOperationException. EncodeRegister's BitInRegister branch repurposed as a defensive guard — if a non-RMW caller ever reaches it, throw so an unintended bypass stays loud rather than silently clobbering. FOCAS — FwlibFocasClient gains WritePmcBitAsync + _rmwLocks keyed on {addrType}:{byteAddr}. Driver-layer WriteAsync routes Bit writes with a bitIndex through the new path; other Pmc writes still hit the direct pmc_wrpmcrng path. RMW uses cnc_rdpmcrng + Byte dataType to grab the parent byte, bit-op with (current | 1<<bit) or (current & ~(1<<bit)), cnc_wrpmcrng to write back. Rejects out-of-range bits (0-7, FOCAS PMC bytes are 8-bit) with InvalidOperationException. EncodePmcValue's Bit branch now treats a no-bitIndex case as whole-byte boolean (non-zero / zero); bitIndex-present writes never hit this path because they dispatch to WritePmcBitAsync upstream. Tests — 5 new ModbusBitRmwTests + 4 new FocasPmcBitRmwTests + 1 renamed pre-existing test each covering — bit set preserves other bits, bit clear preserves other bits, concurrent bit writes to same word/byte compose correctly (8-parallel stress), bit writes on different parent words proceed without contention (4-parallel), sequential bit sets compose into 0xFF after all 8. Fake PmcRmwFake in FOCAS tests simulates the PMC byte storage + surfaces it through the IFocasClient contract so the test asserts driver-level behavior without needing Fwlib32.dll. FwlibNativeHelperTests.EncodePmcValue_Bit_throws_NotSupported_for_RMW_gap replaced with EncodePmcValue_Bit_without_bit_index_writes_byte_boolean reflecting the new behavior. ModbusDataTypeTests.BitInRegister_write_is_not_supported_in_PR24 renamed to BitInRegister_EncodeRegister_still_rejects_direct_calls; the message assertion updated to match the new defensive message. Modbus tests now 182/182, FOCAS tests now 119/119; full solution builds 0 errors; AbCip/AbLegacy/TwinCAT untouched (those get their RMW pass in a follow-up since libplctag bit access may need a parallel parent-word handle). Task #181 stays pending until that second pass lands.
RMW pass 1 — Modbus BitInRegister + FOCAS PMC Bit write paths. First half of task #181 — the two drivers where read-modify-write is a clean protocol-level insertion (Modbus FC03/FC06 round-trip + FOCAS pmc_rdpmcrng / pmc_wrpmcrng round-trip). Per-driver SemaphoreSlim registry keyed on the parent word address serialises concurrent bit writes so two writers targeting different bits in the same word don't lose one another's update. Modbus — ModbusDriver gains WriteBitInRegisterAsync + _rmwLocks ConcurrentDictionary. WriteOneAsync routes BitInRegister (HoldingRegisters region only) through RMW ahead of the normal encode path. Read uses FC03 Read Holding Registers for 1 register at tag.Address, bit-op on the returned ushort via (current | 1<<bit) for set / (current & ~(1<<bit)) for clear, write back via FC06 Write Single Register. Per-address lock prevents concurrent bit writes to the same register from racing. Rejects out-of-range bits (0-15) with InvalidOperationException. EncodeRegister's BitInRegister branch repurposed as a defensive guard — if a non-RMW caller ever reaches it, throw so an unintended bypass stays loud rather than silently clobbering. FOCAS — FwlibFocasClient gains WritePmcBitAsync + _rmwLocks keyed on {addrType}:{byteAddr}. Driver-layer WriteAsync routes Bit writes with a bitIndex through the new path; other Pmc writes still hit the direct pmc_wrpmcrng path. RMW uses cnc_rdpmcrng + Byte dataType to grab the parent byte, bit-op with (current | 1<<bit) or (current & ~(1<<bit)), cnc_wrpmcrng to write back. Rejects out-of-range bits (0-7, FOCAS PMC bytes are 8-bit) with InvalidOperationException. EncodePmcValue's Bit branch now treats a no-bitIndex case as whole-byte boolean (non-zero / zero); bitIndex-present writes never hit this path because they dispatch to WritePmcBitAsync upstream. Tests — 5 new ModbusBitRmwTests + 4 new FocasPmcBitRmwTests + 1 renamed pre-existing test each covering — bit set preserves other bits, bit clear preserves other bits, concurrent bit writes to same word/byte compose correctly (8-parallel stress), bit writes on different parent words proceed without contention (4-parallel), sequential bit sets compose into 0xFF after all 8. Fake PmcRmwFake in FOCAS tests simulates the PMC byte storage + surfaces it through the IFocasClient contract so the test asserts driver-level behavior without needing Fwlib32.dll. FwlibNativeHelperTests.EncodePmcValue_Bit_throws_NotSupported_for_RMW_gap replaced with EncodePmcValue_Bit_without_bit_index_writes_byte_boolean reflecting the new behavior. ModbusDataTypeTests.BitInRegister_write_is_not_supported_in_PR24 renamed to BitInRegister_EncodeRegister_still_rejects_direct_calls; the message assertion updated to match the new defensive message. Modbus tests now 182/182, FOCAS tests now 119/119; full solution builds 0 errors; AbCip/AbLegacy/TwinCAT untouched (those get their RMW pass in a follow-up since libplctag bit access may need a parallel parent-word handle). Task #181 stays pending until that second pass lands.