Renames all 11 projects (5 src + 6 tests), the .slnx solution file, all source-file namespaces, all axaml namespace references, and all v1 documentation references in CLAUDE.md and docs/*.md (excluding docs/v2/ which is already in OtOpcUa form). Also updates the TopShelf service registration name from "LmxOpcUa" to "OtOpcUa" per Phase 0 Task 0.6.
Preserves runtime identifiers per Phase 0 Out-of-Scope rules to avoid breaking v1/v2 client trust during coexistence: OPC UA `ApplicationUri` defaults (`urn:{GalaxyName}:LmxOpcUa`), server `EndpointPath` (`/LmxOpcUa`), `ServerName` default (feeds cert subject CN), `MxAccessConfiguration.ClientName` default (defensive — stays "LmxOpcUa" for MxAccess audit-trail consistency), client OPC UA identifiers (`ApplicationName = "LmxOpcUaClient"`, `ApplicationUri = "urn:localhost:LmxOpcUaClient"`, cert directory `%LocalAppData%\LmxOpcUaClient\pki\`), and the `LmxOpcUaServer` class name (class rename out of Phase 0 scope per Task 0.5 sed pattern; happens in Phase 1 alongside `LmxNodeManager → GenericDriverNodeManager` Core extraction). 23 LmxOpcUa references retained, all enumerated and justified in `docs/v2/implementation/exit-gate-phase-0.md`.
Build clean: 0 errors, 30 warnings (lower than baseline 167). Tests at strict improvement over baseline: 821 passing / 1 failing vs baseline 820 / 2 (one flaky pre-existing failure passed this run; the other still fails — both pre-existing and unrelated to the rename). `Client.UI.Tests`, `Historian.Aveva.Tests`, `Client.Shared.Tests`, `IntegrationTests` all match baseline exactly. Exit gate compliance results recorded in `docs/v2/implementation/exit-gate-phase-0.md` with all 7 checks PASS or DEFERRED-to-PR-review (#7 service install verification needs Windows service permissions on the reviewer's box).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
130 lines
4.2 KiB
C#
130 lines
4.2 KiB
C#
using Opc.Ua;
|
|
using Shouldly;
|
|
using Xunit;
|
|
using ZB.MOM.WW.OtOpcUa.Client.Shared.Models;
|
|
using BrowseResult = ZB.MOM.WW.OtOpcUa.Client.Shared.Models.BrowseResult;
|
|
|
|
namespace ZB.MOM.WW.OtOpcUa.Client.Shared.Tests.Models;
|
|
|
|
public class ModelConstructionTests
|
|
{
|
|
[Fact]
|
|
public void BrowseResult_ConstructsCorrectly()
|
|
{
|
|
var result = new BrowseResult("ns=2;s=MyNode", "MyNode", "Variable", true);
|
|
|
|
result.NodeId.ShouldBe("ns=2;s=MyNode");
|
|
result.DisplayName.ShouldBe("MyNode");
|
|
result.NodeClass.ShouldBe("Variable");
|
|
result.HasChildren.ShouldBeTrue();
|
|
}
|
|
|
|
[Fact]
|
|
public void BrowseResult_WithoutChildren()
|
|
{
|
|
var result = new BrowseResult("ns=2;s=Leaf", "Leaf", "Variable", false);
|
|
result.HasChildren.ShouldBeFalse();
|
|
}
|
|
|
|
[Fact]
|
|
public void AlarmEventArgs_ConstructsCorrectly()
|
|
{
|
|
var time = new DateTime(2026, 1, 15, 10, 30, 0, DateTimeKind.Utc);
|
|
var args = new AlarmEventArgs("Source1", "HighTemp", 500, "Temperature high", true, true, false, time);
|
|
|
|
args.SourceName.ShouldBe("Source1");
|
|
args.ConditionName.ShouldBe("HighTemp");
|
|
args.Severity.ShouldBe((ushort)500);
|
|
args.Message.ShouldBe("Temperature high");
|
|
args.Retain.ShouldBeTrue();
|
|
args.ActiveState.ShouldBeTrue();
|
|
args.AckedState.ShouldBeFalse();
|
|
args.Time.ShouldBe(time);
|
|
}
|
|
|
|
[Fact]
|
|
public void RedundancyInfo_ConstructsCorrectly()
|
|
{
|
|
var uris = new[] { "urn:server1", "urn:server2" };
|
|
var info = new RedundancyInfo("Warm", 200, uris, "urn:server1");
|
|
|
|
info.Mode.ShouldBe("Warm");
|
|
info.ServiceLevel.ShouldBe((byte)200);
|
|
info.ServerUris.ShouldBe(uris);
|
|
info.ApplicationUri.ShouldBe("urn:server1");
|
|
}
|
|
|
|
[Fact]
|
|
public void RedundancyInfo_WithEmptyUris()
|
|
{
|
|
var info = new RedundancyInfo("None", 0, [], string.Empty);
|
|
info.ServerUris.ShouldBeEmpty();
|
|
info.ApplicationUri.ShouldBeEmpty();
|
|
}
|
|
|
|
[Fact]
|
|
public void DataChangedEventArgs_ConstructsCorrectly()
|
|
{
|
|
var value = new DataValue(new Variant(42), StatusCodes.Good);
|
|
var args = new DataChangedEventArgs("ns=2;s=Temp", value);
|
|
|
|
args.NodeId.ShouldBe("ns=2;s=Temp");
|
|
args.Value.ShouldBe(value);
|
|
args.Value.Value.ShouldBe(42);
|
|
}
|
|
|
|
[Fact]
|
|
public void ConnectionStateChangedEventArgs_ConstructsCorrectly()
|
|
{
|
|
var args = new ConnectionStateChangedEventArgs(
|
|
ConnectionState.Disconnected, ConnectionState.Connected, "opc.tcp://localhost:4840");
|
|
|
|
args.OldState.ShouldBe(ConnectionState.Disconnected);
|
|
args.NewState.ShouldBe(ConnectionState.Connected);
|
|
args.EndpointUrl.ShouldBe("opc.tcp://localhost:4840");
|
|
}
|
|
|
|
[Fact]
|
|
public void ConnectionInfo_ConstructsCorrectly()
|
|
{
|
|
var info = new ConnectionInfo(
|
|
"opc.tcp://localhost:4840",
|
|
"TestServer",
|
|
"None",
|
|
"http://opcfoundation.org/UA/SecurityPolicy#None",
|
|
"ns=0;i=12345",
|
|
"TestSession");
|
|
|
|
info.EndpointUrl.ShouldBe("opc.tcp://localhost:4840");
|
|
info.ServerName.ShouldBe("TestServer");
|
|
info.SecurityMode.ShouldBe("None");
|
|
info.SecurityPolicyUri.ShouldBe("http://opcfoundation.org/UA/SecurityPolicy#None");
|
|
info.SessionId.ShouldBe("ns=0;i=12345");
|
|
info.SessionName.ShouldBe("TestSession");
|
|
}
|
|
|
|
[Fact]
|
|
public void SecurityMode_Enum_HasExpectedValues()
|
|
{
|
|
Enum.GetValues<SecurityMode>().Length.ShouldBe(3);
|
|
((int)SecurityMode.None).ShouldBe(0);
|
|
((int)SecurityMode.Sign).ShouldBe(1);
|
|
((int)SecurityMode.SignAndEncrypt).ShouldBe(2);
|
|
}
|
|
|
|
[Fact]
|
|
public void ConnectionState_Enum_HasExpectedValues()
|
|
{
|
|
Enum.GetValues<ConnectionState>().Length.ShouldBe(4);
|
|
((int)ConnectionState.Disconnected).ShouldBe(0);
|
|
((int)ConnectionState.Connecting).ShouldBe(1);
|
|
((int)ConnectionState.Connected).ShouldBe(2);
|
|
((int)ConnectionState.Reconnecting).ShouldBe(3);
|
|
}
|
|
|
|
[Fact]
|
|
public void AggregateType_Enum_HasExpectedValues()
|
|
{
|
|
Enum.GetValues<AggregateType>().Length.ShouldBe(7);
|
|
}
|
|
} |