Files
lmxopcua/src/ZB.MOM.WW.OtOpcUa.Driver.Galaxy.Proxy
Joseph Doherty bf329b05d8 Phase 3 PR 35 — IHistoryProvider gains ReadAtTimeAsync + ReadEventsAsync; GalaxyProxyDriver implements both. Extends Core.Abstractions.IHistoryProvider with two new methods that round out the OPC UA Part 11 HistoryRead surface (HistoryReadAtTime + HistoryReadEvents are the last two modes not covered by the PR 19-era ReadRawAsync + ReadProcessedAsync) and wires GalaxyProxyDriver to call the existing PR-10/PR-11 IPC contracts the Host already implements.
Interface additions use C# default interface implementations that throw NotSupportedException — existing IHistoryProvider implementations keep compiling, only drivers whose backend carries the relevant capability override. This matches the 'capabilities are optional per driver' design already used by IHistoryProvider.ReadProcessedAsync's docs (Modbus / OPC UA Client drivers never had an event historian and the default-throw path lets callers see BadHistoryOperationUnsupported naturally). New HistoricalEvent record models one historian row (EventId, SourceName, EventTimeUtc + ReceivedTimeUtc — process vs historian-persist timestamps, Message, Severity mapped to OPC UA's 1-1000 range); HistoricalEventsResult pairs the event list with a continuation-point token for future batching. Both live in Core.Abstractions so downstream (Proxy, Host, Server) reference a single domain shape — no Shared-contract leak into the driver-facing interface.
GalaxyProxyDriver.ReadAtTimeAsync maps the domain DateTime[] to Unix-ms longs, calls CallAsync on the existing MessageKind.HistoryReadAtTimeRequest, and trusts the Host's one-sample-per-requested-timestamp contract (the Host pads with bad-quality snapshots for timestamps it can't interpolate; re-aligning on the Proxy side would duplicate the Host's interpolation policy logic). ReadEventsAsync does the same for HistoryReadEventsRequest; ToHistoricalEvent translates GalaxyHistoricalEvent (MessagePack-annotated, Unix-ms) to the domain record, explicitly tagging DateTimeKind.Utc on both timestamp fields so downstream serializers (JSON, OPC UA types) don't apply an unexpected local-time offset.
Tests — HistoricalEventMappingTests (3 new Proxy.Tests unit cases): every field maps correctly from wire to domain; null SourceName and null DisplayText preserve through the mapping (system events without a source come out with null so callers can distinguish them from alarm events); both timestamps come out as DateTimeKind.Utc (regression guard against a future refactor using DateTime.FromFileTimeUtc or similar that defaults to Unspecified). Driver.Galaxy.Proxy.Tests Unit suite: 17 pass / 0 fail (14 prior + 3 new). Full solution build clean, 0 errors.
Scope exclusions — DriverNodeManager HistoryRead service-handler wiring (on the OPC UA Server side, where HistoryReadAtTime and HistoryReadEvents service requests land) and the full-loop integration test (OPC UA client → server → IPC → Host → HistorianDataSource → back) are deferred to a focused follow-up PR. The capability surface is the load-bearing change; wiring the service handlers is mechanical in comparison and worth its own PR for reviewability. docs/v2/lmx-followups.md #1 updated with the split.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-18 16:08:27 -04:00
..
Phase 2 Streams A+B+C feature-complete — real Win32 pump, all 9 IDriver capabilities, end-to-end IPC dispatch. Streams D+E remain (Galaxy MXAccess code lift + parity-debug cycle, plan-budgeted 3-4 weeks). The 494 v1 IntegrationTests still pass — legacy OtOpcUa.Host untouched. StaPump replaces the BlockingCollection placeholder with a real Win32 message pump lifted from v1 StaComThread per CLAUDE.md "Reference Implementation": dedicated STA Thread with SetApartmentState(STA), GetMessage/PostThreadMessage/PeekMessage/TranslateMessage/DispatchMessage/PostQuitMessage P/Invoke, WM_APP=0x8000 for work-item dispatch, WM_APP+1 for graceful-drain → PostQuitMessage, peek-pm-noremove on entry to force the system to create the thread message queue before signalling Started, IsResponsiveAsync probe still no-op-round-trips through PostThreadMessage so the wedge detection works against the real pump. Concurrent ConcurrentQueue<WorkItem> drains on every WM_APP; fault path on dispose drains-and-faults all pending work-item TCSes with InvalidOperationException("STA pump has exited"). All three StaPumpTests pass against the real pump (apartment state STA, healthy probe true, wedged probe false). GalaxyProxyDriver now implements every Phase 2 Stream C capability — IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IAlarmSource, IHistoryProvider, IRediscoverable, IHostConnectivityProbe — each forwarding through the matching IPC contract. ReadAsync preserves request order even when the Host returns out-of-order values; WriteAsync MessagePack-serializes the value into ValueBytes; SubscribeAsync wraps SubscriptionId in a GalaxySubscriptionHandle record; UnsubscribeAsync uses the new SendOneWayAsync helper on GalaxyIpcClient (fire-and-forget but still gated through the call-semaphore so it doesn't interleave with CallAsync); AlarmSubscribe is one-way and the Host pushes events back via OnAlarmEvent; ReadProcessedAsync short-circuits to NotSupportedException (Galaxy historian only does raw); IRediscoverable's OnRediscoveryNeeded fires when the Host pushes a deploy-watermark notification; IHostConnectivityProbe.GetHostStatuses() snapshots and OnHostStatusChanged fires on Running↔Stopped/Faulted transitions, with IpcHostConnectivityStatus aliased to disambiguate from the Core.Abstractions namespace's same-named type. Internal RaiseDataChange/RaiseAlarmEvent/RaiseRediscoveryNeeded/OnHostConnectivityUpdate methods are the entry points the IPC client will invoke when push frames arrive. Host side: new Backend/IGalaxyBackend interface defines the seam between IPC dispatch and the live MXAccess code (so the dispatcher is unit-testable against an in-memory mock without needing live Galaxy); Backend/StubGalaxyBackend returns success for OpenSession/CloseSession/Subscribe/Unsubscribe/AlarmSubscribe/AlarmAck/Recycle and a recognizable "stub: MXAccess code lift pending (Phase 2 Task B.1)"-tagged error for Discover/ReadValues/WriteValues/HistoryRead — keeps the IPC end-to-end testable today and gives the parity team a clear seam to slot the real implementation into; Ipc/GalaxyFrameHandler is the new real dispatcher (replaces StubFrameHandler in Program.cs) — switch on MessageKind, deserialize the matching contract, await backend method, write the response (one-way for Unsubscribe/AlarmSubscribe/AlarmAck/CloseSession), heartbeat handled inline so liveness still works if the backend is sick, exceptions caught and surfaced as ErrorResponse with code "handler-exception" so the Proxy raises GalaxyIpcException instead of disconnecting. End-to-end IPC integration test (EndToEndIpcTests) drives every operation through the full stack — Initialize → Read → Write → Subscribe → Unsubscribe → SubscribeAlarms → AlarmAck → ReadRaw → ReadProcessed (short-circuit) — proving the wire protocol, dispatcher, capability forwarding, and one-way semantics agree end-to-end. Skipped on Windows administrator shells per the same PipeAcl-denies-Administrators reasoning the IpcHandshakeIntegrationTests use. Full solution 952 pass / 1 pre-existing Phase 0 baseline. Phase 2 evidence doc updated: status header now reads "Streams A+B+C complete... Streams D+E remain — gated only on the iterative Galaxy code lift + parity-debug cycle"; new Update 2026-04-17 (later) callout enumerates the upgrade with explicit "what's left for the Phase 2 exit gate" — replace StubGalaxyBackend with a MxAccessClient-backed implementation calling on the StaPump, then run the v1 IntegrationTests against the v2 topology and iterate on parity defects until green, then delete legacy OtOpcUa.Host.
2026-04-17 23:02:00 -04:00
Phase 1 Streams B–E scaffold + Phase 2 Streams A–C scaffold — 8 new projects with ~70 new tests, all green alongside the 494 v1 IntegrationTests baseline (parity preserved: no v1 tests broken; legacy OtOpcUa.Host untouched). Phase 1 finish: Configuration project (16 entities + 10 enums + DbContext + DesignTimeDbContextFactory + InitialSchema/StoredProcedures/AuthorizationGrants migrations — 8 procs including sp_PublishGeneration with MERGE on ExternalIdReservation per decision #124, sp_RollbackToGeneration cloning rows into a new published generation, sp_ValidateDraft with cross-cluster-namespace + EquipmentUuid-immutability + ZTag/SAPID reservation pre-flight, sp_ComputeGenerationDiff with CHECKSUM-based row signature — plus OtOpcUaNode/OtOpcUaAdmin SQL roles with EXECUTE grants scoped to per-principal-class proc sets and DENY UPDATE/DELETE/INSERT/SELECT on dbo schema); managed DraftValidator covering UNS segment regex, path length, EquipmentUuid immutability across generations, same-cluster namespace binding (decision #122), reservation pre-flight, EquipmentId derivation (decision #125), driver↔namespace compatibility — returning every failing rule in one pass; LiteDB local cache with round-trip + ring pruning + corruption-fast-fail; GenerationApplier with per-entity Added/Removed/Modified diff and dependency-ordered callbacks (namespace → driver → device → equipment → poll-group → tag, Removed before Added); Core project with GenericDriverNodeManager (scaffold for the Phase 2 Galaxy port) and DriverHost lifecycle registry; Server project using Microsoft.Extensions.Hosting BackgroundService replacing TopShelf, with NodeBootstrap that falls back to LiteDB cache when the central DB is unreachable (decision #79); Admin project scaffolded as Blazor Server with Bootstrap 5 sidebar layout, cookie auth, three admin roles (ConfigViewer/ConfigEditor/FleetAdmin), Cluster + Generation services fronting the stored procs. Phase 2 scaffold: Driver.Galaxy.Shared (netstandard2.0) with full MessagePack IPC contract surface — Hello version negotiation, Open/CloseSession, Heartbeat, DiscoverHierarchy + GalaxyObjectInfo/GalaxyAttributeInfo, Read/WriteValues, Subscribe/Unsubscribe/OnDataChange, AlarmSubscribe/Event/Ack, HistoryRead, HostConnectivityStatus, Recycle — plus length-prefixed framing (decision #28) with a 16 MiB cap and thread-safe FrameWriter/FrameReader; Driver.Galaxy.Host (net48) implementing the Tier C cross-cutting protections from driver-stability.md — strict PipeAcl (allow configured server SID only, explicit deny on LocalSystem + Administrators), PipeServer with caller-SID verification via pipe.RunAsClient + WindowsIdentity.GetCurrent and per-process shared-secret Hello, Galaxy-specific MemoryWatchdog (warn at max(1.5×baseline, +200 MB), soft-recycle at max(2×baseline, +200 MB), hard ceiling 1.5 GB, slope ≥5 MB/min over 30-min rolling window), RecyclePolicy (1 soft recycle per hour cap + 03:00 local daily scheduled), PostMortemMmf (1000-entry ring buffer in %ProgramData%\OtOpcUa\driver-postmortem\galaxy.mmf, survives hard crash, readable cross-process), MxAccessHandle : SafeHandle (ReleaseHandle loops Marshal.ReleaseComObject until refcount=0 then calls optional unregister callback), StaPump with responsiveness probe (BlockingCollection dispatcher for Phase 1 — real Win32 GetMessage/DispatchMessage pump slots in with the same semantics when the Galaxy code lift happens), IsExternalInit shim for init setters on .NET 4.8; Driver.Galaxy.Proxy (net10) implementing IDriver + ITagDiscovery forwarding over the IPC channel with MX data-type and security-classification mapping, plus Supervisor pieces — Backoff (5s → 15s → 60s capped, reset-on-stable-run), CircuitBreaker (3 crashes per 5 min opens; 1h → 4h → manual cooldown escalation; sticky alert doesn't auto-clear), HeartbeatMonitor (2s cadence, 3 consecutive misses = host dead per driver-stability.md). Infrastructure: docker SQL Server remapped to host port 14330 to coexist with the native MSSQL14 Galaxy ZB DB instance on 1433; NuGetAuditSuppress applied per-project for two System.Security.Cryptography.Xml advisories that only reach via EF Core Design with PrivateAssets=all (fix ships in 11.0.0-preview); .slnx gains 14 project registrations. Deferred with explicit TODOs in docs/v2/implementation/phase-2-partial-exit-evidence.md: Phase 1 Stream E Admin UI pages (Generations listing + draft-diff-publish, Equipment CRUD with OPC 40010 fields, UNS Areas/Lines tabs, ACLs + permission simulator, Generic JSON config editor, SignalR real-time, Release-Reservation + Merge-Equipment workflows, LDAP login page, AppServer smoke test per decision #142), Phase 2 Stream D (Galaxy MXAccess code lift out of legacy OtOpcUa.Host, dual-service installer, appsettings → DriverConfig migration script, legacy Host deletion — blocked by parity), Phase 2 Stream E (v1 IntegrationTests against v2 topology, Client.CLI walkthrough diff, four 2026-04-13 stability findings regression tests, adversarial review — requires live MXAccess runtime).
2026-04-17 21:35:25 -04:00
Phase 2 PR 7 — wire IHistoryProvider.ReadProcessedAsync end-to-end. PR 5 ported HistorianDataSource.ReadAggregateAsync into Galaxy.Host but left it internal — GalaxyProxyDriver.ReadProcessedAsync still threw NotSupportedException, so OPC UA clients issuing HistoryReadProcessed requests against the v2 topology got rejected at the driver boundary. This PR closes that gap by adding two new Shared.Contracts messages (HistoryReadProcessedRequest/Response, MessageKind 0x62/0x63), routing them through GalaxyFrameHandler, implementing HistoryReadProcessedAsync on all three IGalaxyBackend implementations (Stub/DbBacked return the canonical "pending" Success=false, MxAccessGalaxyBackend delegates to _historian.ReadAggregateAsync), mapping HistorianAggregateSample → GalaxyDataValue at the IPC boundary (null bucket Value → BadNoData 0x800E0000u, otherwise Good 0u), and flipping GalaxyProxyDriver.ReadProcessedAsync from the NotSupported throw to a real IPC call with OPC UA HistoryAggregateType enum mapped to Wonderware AnalogSummary column name on the Proxy side (Average → "Average", Minimum → "Minimum", Maximum → "Maximum", Count → "ValueCount", Total → NotSupported since there's no direct SDK column for sum). Decision #13 IPC data-shape stays intact — HistoryReadProcessedResponse carries GalaxyDataValue[] with the same MessagePack value + OPC UA StatusCode + timestamps shape as the other history responses, so the Proxy's existing ToSnapshot helper handles the conversion without a new code path. MxAccessGalaxyBackend.HistoryReadProcessedAsync guards: null historian → "Historian disabled" (symmetric with HistoryReadAsync); IntervalMs <= 0 → "HistoryReadProcessed requires IntervalMs > 0" (prevents division-by-zero inside the SDK's Resolution parameter); exception during SDK call → Success=false Values=[] with the message so the Proxy surfaces it as InvalidOperationException with a clean error chain. Tests — HistoryReadProcessedTests (new, 4 cases): disabled-error when historian null, rejects zero interval, maps Good sample with Value=12.34 and the Proxy-supplied AggregateColumn + IntervalMs flow unchanged through to the fake IHistorianDataSource, maps null Value bucket to 0x800E0000u BadNoData with null ValueBytes. AggregateColumnMappingTests (new, 5 cases in Proxy.Tests): theory covers all 4 supported HistoryAggregateType enum values → correct column string, and asserts Total throws NotSupportedException with a message that steers callers to Average/Minimum/Maximum/Count (the SDK's AnalogSummaryQueryResult doesn't expose a sum column — the closest is Average × ValueCount which is the responsibility of a caller-side aggregation rather than an extra IPC round-trip). InternalsVisibleTo added to Galaxy.Proxy csproj so Proxy.Tests can reach the internal MapAggregateToColumn static. Builds — Galaxy.Host (net48 x86) + Galaxy.Proxy (net10) both 0 errors, full solution 201 warnings (pre-existing) / 0 errors. Test counts — Host.Tests Unit suite: 28 pass (4 new processed + 9 PR5 historian + 15 pre-existing); Proxy.Tests Unit suite: 14 pass (5 new column-mapping + 9 pre-existing). Deferred to a later PR — ReadAtTime + ReadEvents + Health IPC surfaces (HistorianDataSource has them ported in PR 5 but they need additional contract messages and would push this PR past a comfortable review size); the alarm subsystem wire-up (OnAlarmEvent raising from MxAccessGalaxyBackend) which overlaps the ReadEventsAsync IPC work since both pull from HistorianAccess.CreateEventQuery on the SDK side; the Proxy-side quality-byte refinement where HistorianDataSource's per-sample raw quality byte gets decoded through the existing QualityMapper instead of the category-only mapping in ToWire(HistorianSample) — doesn't change correctness today since Good/Uncertain/Bad categories are all the Admin UI and OPC UA clients surface, but richer OPC DA status codes (BadNotConnected, UncertainSubNormal, etc.) are available on the wire and the Proxy could promote them before handing DataValueSnapshot to ISubscribable consumers. This PR branches off phase-2-pr5-historian because it directly extends the Historian IPC surface added there; if PR 5 merges first PR 7 fast-forwards, otherwise it needs a rebase after PR 5 lands.
2026-04-18 05:53:01 -04:00