Wave-B EXEMPLAR. Retire the pre-declared/blob-parse tag model; the driver now builds its RawPath -> definition table from the artifact's RawTagEntry set via a pure mapper. - Contracts: rename ModbusEquipmentTagParser -> ModbusTagDefinitionFactory; TryParse(reference) -> FromTagConfig(tagConfig, rawPath) (def.Name = rawPath, no leading-brace heuristic); add inverse ToTagConfig(def) serializer; keep all strict-enum reads + guards; also read stringByteOrder/deadband/coalesceProhibited so a RawTagEntry round-trips the full authored def. Inspect() unchanged. - Options: Tags(IReadOnlyList<ModbusTagDefinition>) -> RawTags(IReadOnlyList<RawTagEntry>). - Driver: _tagsByName -> _tagsByRawPath (Ordinal); resolver byRawPath-only; build the table from RawTags at Initialize threading entry.WriteIdempotent onto each def; Discover/Teardown updated. - Factory: remove ModbusTagDto/BuildTag/ValidateStringLength + ConfigDto.Tags; bind RawTags from driver-config JSON. - CLI ModbusCommandBase.BuildOptions: serialise typed defs -> RawTagEntry via ToTagConfig. - Tests: migrate Tags= -> RawTags via ModbusRawTags.Entries helper; parser tests -> FromTagConfig(rawPath); factory String-length/enum tests re-seated on the mapper seam. - Propagated rename to ControlPlane EquipmentTagConfigInspector (outside Modbus projects). Modbus.Tests 315/315, Addressing.Tests 161/161, Cli.Tests 72/72 green. Docker-gated Driver.Modbus.IntegrationTests left untouched (won't compile against the new API; expected).
86 lines
4.3 KiB
C#
86 lines
4.3 KiB
C#
using Shouldly;
|
|
using Xunit;
|
|
|
|
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests;
|
|
|
|
/// <summary>
|
|
/// Regression coverage for Driver.Modbus-009: two configuration edge cases that previously
|
|
/// silently produced wrong wire behaviour.
|
|
/// (1) <c>StringLength = 0</c> for a <c>String</c>-typed tag — used to flow into an FC03
|
|
/// with quantity 0, a spec-illegal request the PLC rejects with exception 03. In v3 the guard
|
|
/// moved to the pure mapper (<see cref="ModbusTagDefinitionFactory.FromTagConfig"/>): a String
|
|
/// tag with <c>stringLength < 1</c> fails to map (⇒ the driver skips it / surfaces
|
|
/// <c>BadNodeIdUnknown</c>) instead of the factory throwing at bind time.
|
|
/// (2) Sub-second <see cref="TimeSpan"/> values on <c>ModbusKeepAliveOptions.Time</c> /
|
|
/// <c>Interval</c> — the int-cast in <c>EnableKeepAlive</c> truncated <c>500 ms</c> to
|
|
/// <c>0</c>, which most OSes interpret as "use the default", silently defeating the
|
|
/// configured timing. <c>ModbusTcpTransport.ClampToWholeSeconds</c> rounds up to a minimum
|
|
/// of 1 second.
|
|
/// </summary>
|
|
[Trait("Category", "Unit")]
|
|
public sealed class ModbusEdgeCaseValidationTests
|
|
{
|
|
private const string RawPath = "cell/modbus/dev1/Greeting";
|
|
|
|
/// <summary>Verifies that a String tag with an explicit zero length fails to map.</summary>
|
|
[Fact]
|
|
public void Mapper_rejects_String_tag_with_StringLength_zero_explicit()
|
|
{
|
|
const string json = """{"region":"HoldingRegisters","address":100,"dataType":"String","stringLength":0}""";
|
|
ModbusTagDefinitionFactory.FromTagConfig(json, RawPath, out _).ShouldBeFalse();
|
|
}
|
|
|
|
/// <summary>Verifies that a String tag with an omitted length (defaults to zero) fails to map.</summary>
|
|
[Fact]
|
|
public void Mapper_rejects_String_tag_with_StringLength_zero_missing_field()
|
|
{
|
|
// No stringLength → defaults to 0. Same misconfiguration via a different blob shape.
|
|
const string json = """{"region":"HoldingRegisters","address":100,"dataType":"String"}""";
|
|
ModbusTagDefinitionFactory.FromTagConfig(json, RawPath, out _).ShouldBeFalse();
|
|
}
|
|
|
|
/// <summary>Verifies that a String tag with length one maps successfully.</summary>
|
|
[Fact]
|
|
public void Mapper_accepts_String_tag_with_StringLength_one()
|
|
{
|
|
const string json = """{"region":"HoldingRegisters","address":100,"dataType":"String","stringLength":1}""";
|
|
ModbusTagDefinitionFactory.FromTagConfig(json, RawPath, out var def).ShouldBeTrue();
|
|
def.StringLength.ShouldBe((ushort)1);
|
|
}
|
|
|
|
/// <summary>Verifies that non-String tags are unaffected by a zero string length.</summary>
|
|
[Fact]
|
|
public void Mapper_accepts_non_String_tag_with_StringLength_zero()
|
|
{
|
|
// The guard only kicks in for String tags — Int16 tags with StringLength=0 are normal.
|
|
const string json = """{"region":"HoldingRegisters","address":100,"dataType":"Int16"}""";
|
|
ModbusTagDefinitionFactory.FromTagConfig(json, RawPath, out _).ShouldBeTrue();
|
|
}
|
|
|
|
/// <summary>Verifies that sub-second time spans are rounded up to at least one second.</summary>
|
|
/// <param name="ms">The input duration in milliseconds.</param>
|
|
/// <param name="expected">The expected clamped value in whole seconds.</param>
|
|
[Theory]
|
|
[InlineData(0, 1)] // zero clamps up to 1
|
|
[InlineData(500, 1)] // 500 ms rounds up to 1
|
|
[InlineData(999, 1)] // just under 1s rounds up to 1
|
|
[InlineData(1_000, 1)] // exactly 1s passes through
|
|
[InlineData(1_500, 2)] // 1.5s rounds up to 2
|
|
[InlineData(30_000, 30)] // historical PR 53 default — unchanged
|
|
[InlineData(60_000, 60)]
|
|
public void ClampToWholeSeconds_rounds_up_to_at_least_one_second(int ms, int expected)
|
|
{
|
|
ModbusTcpTransport.ClampToWholeSeconds(TimeSpan.FromMilliseconds(ms)).ShouldBe(expected);
|
|
}
|
|
|
|
/// <summary>Verifies that negative time spans are treated as one second.</summary>
|
|
[Fact]
|
|
public void ClampToWholeSeconds_treats_negative_TimeSpan_as_one_second()
|
|
{
|
|
// Defensive — operators occasionally configure a negative TimeSpan thinking it disables
|
|
// the feature. The OS would reject the negative int — clamping to 1 keeps the socket
|
|
// valid until the operator fixes the config.
|
|
ModbusTcpTransport.ClampToWholeSeconds(TimeSpan.FromSeconds(-5)).ShouldBe(1);
|
|
}
|
|
}
|