lmxopcua/tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/Mitsubishi/MitsubishiProfile.cs
T
Joseph Doherty a4c61989b2 test(v3): migrate 6 driver IntegrationTests to RawTags API
Replace pre-declared options.Tags (typed <Driver>TagDefinition lists) with
options.RawTags (IReadOnlyList<RawTagEntry>) across all 6 Docker-gated driver
integration suites so they COMPILE against the v3 driver API.

Each project gets a local <Driver>RawTags helper mirroring the unit-test
project's helper: it serialises a typed def back to its TagConfig blob via the
driver's <Driver>TagDefinitionFactory.ToTagConfig and packages it as a
RawTagEntry (RawPath = def.Name; DeviceName = def.DeviceHostAddress for the
multi-device drivers AbCip/AbLegacy/TwinCAT/FOCAS). Test intent (addresses,
data types, device routing, assertions) is unchanged — only the
tag-authoring/config-delivery shape was migrated.

Docker-gated: these still skip at runtime without fixtures; COMPILE is the gate.
2026-07-15 20:59:42 -04:00

46 lines
2.0 KiB
C#

namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests.Mitsubishi;
/// <summary>
/// Tag map for the Mitsubishi MELSEC device class with a representative Modbus Device
/// Assignment block mapping D0..D1023 → HR[0..1023]. Mirrors the behaviors in
/// <c>mitsubishi.json</c> pymodbus profile and <c>docs/v2/mitsubishi.md</c>.
/// </summary>
/// <remarks>
/// MELSEC Modbus sites all have *different* device-assignment parameter blocks; this profile
/// models the conventional default. Per-model differences (FX5U needs firmware ≥ 1.060 for
/// Modbus server; QJ71MT91 lacks FC22/FC23; FX/iQ-F use octal X/Y while Q/L/iQ-R use hex)
/// are handled in <see cref="MelsecAddress"/> (PR 59) and the per-model test files.
/// </remarks>
public static class MitsubishiProfile
{
/// <summary>
/// Scratch HR the smoke test writes + reads. Address 200 mirrors the
/// dl205/s7_1500/standard scratch range so one smoke test pattern works across every
/// device profile the simulator supports.
/// </summary>
public const ushort SmokeHoldingRegister = 200;
/// <summary>Value the smoke test writes then reads back.</summary>
public const short SmokeHoldingValue = 7890;
/// <summary>Builds Modbus driver options configured for the Mitsubishi profile.</summary>
/// <param name="host">The Modbus server hostname or IP address.</param>
/// <param name="port">The Modbus server port number.</param>
public static ModbusDriverOptions BuildOptions(string host, int port) => new()
{
Host = host,
Port = port,
UnitId = 1,
Timeout = TimeSpan.FromSeconds(2),
RawTags = ModbusRawTags.Entries([
new ModbusTagDefinition(
Name: "Smoke_HReg200",
Region: ModbusRegion.HoldingRegisters,
Address: SmokeHoldingRegister,
DataType: ModbusDataType.Int16,
Writable: true),
]),
Probe = new ModbusProbeOptions { Enabled = false },
};
}