Files
lmxopcua/scripts/validation/scadabridge-sdk-compatibility/README.md
T
2026-11-12 07:01:24 -05:00

3.1 KiB

Actual ScadaBridge consumer compatibility

This isolated process references the real ScadaBridge OpcUaDataConnection and RealOpcUaClient, with their own dependency graph. It never loads the candidate SDK into that process. The verified consumer source is 0e89966da670e289bd875166295bb0e85d8cf8b2, pinned to SDK 1.5.378.106.

Build with an explicit clean consumer checkout:

dotnet build scripts/validation/scadabridge-sdk-compatibility/Probe.csproj \
  -c Release -p:ScadaBridgeSourceRoot=/absolute/ScadaBridge

First build the separate application hosts with the parent scripts/e2e/test-opcua-sdk-compatibility.ps1 harness. Then choose a new output directory and pass its original and candidate ProcessHost.dll paths:

python3 scripts/validation/scadabridge-sdk-compatibility/run.py \
  --baseline-host /absolute/matrix/build-baseline/bin/Release/net10.0/ProcessHost.dll \
  --candidate-host /absolute/matrix/build-candidate/bin/Release/net10.0/ProcessHost.dll \
  --probe scripts/validation/scadabridge-sdk-compatibility/bin/Release/net10.0/Probe.dll \
  --results /absolute/fresh-consumer-evidence

The helper runs each application version with None, Sign and SignAndEncrypt, plus two trust negative controls per secure profile (server does not trust the client, client does not trust the server) that must fail closed. None and Sign are enabled only in their own test fixtures (OPCUA_MATRIX_SERVER_SECURITY=none|sign); the ordinary compatibility host remains strict SignAndEncrypt. Before each secure leg the probe's prepare step provisions the consumer identity through ScadaBridge's own certificate code and exports only its public certificate, which the runner places in the server's trusted store before the server starts. OPCUA_MATRIX_ACL=off disables the server's node-ACL check; with it on, masters after lmxopcua#808 deny the three UNS cases because this fixture creates the Eq folder without a deployed generation (fixture limitation, see lmxopcua#782). The task key is generated per process pair, issuer/trusted/rejected stores are task-local, and server public certificates are explicitly copied. Autoaccept remains false. Never commit an entire output directory: it contains the fixture's private PKI.

The consumed subset covers API-key activation, raw/UNS scalar and Int32[] roundtrips, durable hierarchical browse including the native alarm, data quality and timestamps, alarm filter/ConditionRefresh and disconnect/reconnect. History and Part 9 acknowledgment are not exposed by the inspected consumer interfaces; the parent Shared/CLI matrix covers those application services instead.

ScadaBridge#121 (consumer never configured an application certificate) is fixed in ScadaBridge ff835447/36c64a6b. Re-run 2026-11-12 with ScadaBridge 424db155: None, Sign and SignAndEncrypt 9/9 against the SDK 1.5.378 baseline (83ed880e), the SDK 2.0.1 candidate (ebdc5892) and master 182fb353 with ACL off; all trust negative controls failed closed. The runner retains the nonzero result and each actual failure; it does not loosen trust or change expected results to return success. No ScadaBridge production source or user PKI is modified.