Group all 69 projects into category subfolders under src/ and tests/ so the Rider Solution Explorer mirrors the module structure. Folders: Core, Server, Drivers (with a nested Driver CLIs subfolder), Client, Tooling. - Move every project folder on disk with git mv (history preserved as renames). - Recompute relative paths in 57 .csproj files: cross-category ProjectReferences, the lib/ HintPath+None refs in Driver.Historian.Wonderware, and the external mxaccessgw refs in Driver.Galaxy and its test project. - Rebuild ZB.MOM.WW.OtOpcUa.slnx with nested solution folders. - Re-prefix project paths in functional scripts (e2e, compliance, smoke SQL, integration, install). Build green (0 errors); unit tests pass. Docs left for a separate pass. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
52 lines
1.9 KiB
C#
52 lines
1.9 KiB
C#
namespace ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Wire;
|
|
|
|
/// <summary>
|
|
/// Thrown by the wire client when a FOCAS request fails — either at the protocol layer
|
|
/// (invalid PDU magic, desynchronised response framing, connection dropped mid-request)
|
|
/// or when the CNC returns a non-zero <c>EW_*</c> return code.
|
|
/// </summary>
|
|
/// <remarks>
|
|
/// <para>Callers distinguish the two classes via <see cref="IsTransient"/>: <c>true</c>
|
|
/// when the transport is gone (socket closed, timeout, cancellation mid-write) and the
|
|
/// wire client has already torn the sockets down, so a reconnect is required before any
|
|
/// further call. <c>false</c> for protocol-level errors where the connection is still
|
|
/// usable.</para>
|
|
/// <para><see cref="Rc"/> carries the wire-level FOCAS return code when the exception
|
|
/// came from a parsed response block. Null when the failure happened before a response
|
|
/// was received (e.g. connect-time handshake errors).</para>
|
|
/// </remarks>
|
|
public class FocasWireException : Exception
|
|
{
|
|
/// <summary>FOCAS <c>EW_*</c> return code from the response block, when available.</summary>
|
|
public short? Rc { get; }
|
|
|
|
/// <summary>
|
|
/// True when the transport was closed as a side effect of this failure — the caller
|
|
/// must reconnect before issuing the next request.
|
|
/// </summary>
|
|
public bool IsTransient { get; }
|
|
|
|
public FocasWireException(string message)
|
|
: base(message)
|
|
{
|
|
}
|
|
|
|
public FocasWireException(string message, short? rc, bool isTransient = false)
|
|
: base(message)
|
|
{
|
|
Rc = rc;
|
|
IsTransient = isTransient;
|
|
}
|
|
|
|
public FocasWireException(string message, Exception innerException)
|
|
: base(message, innerException)
|
|
{
|
|
}
|
|
|
|
public FocasWireException(string message, Exception innerException, bool isTransient)
|
|
: base(message, innerException)
|
|
{
|
|