Joseph Doherty 4083b4aada fix(twincat): warn once per bad tag; a device refusal is not a comms fault (P10)
CompleteRead logged a Warning for every non-Good status on every poll and
latched Degraded for all of them. Now a bad tag warns once per bad episode
(re-armed when it reads Good, and on re-initialise), a comms-class status
(BadCommunicationError / BadTimeout) degrades with LastSuccessfulRead
preserved, and any other status - the device answered and refused this tag -
advances LastSuccessfulRead with no state change. Read-path exception
handlers now go through MarkCommsFault, so they never downgrade Faulted.

Refs #739
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 14:07:03 -04:00

27 lines
1.0 KiB
C#

using Microsoft.Extensions.Logging;
using ZB.MOM.WW.OtOpcUa.Driver.TwinCAT;
namespace ZB.MOM.WW.OtOpcUa.Driver.TwinCAT.Tests;
/// <summary>Collects the driver's Warning-level messages (thread-safe) for once-per-X assertions.</summary>
internal sealed class TwinCATCapturingLogger : ILogger<TwinCATDriver>
{
private readonly List<string> _warnings = [];
/// <summary>Gets a snapshot of the formatted Warning messages logged so far.</summary>
public IReadOnlyList<string> Warnings { get { lock (_warnings) return [.. _warnings]; } }
/// <inheritdoc />
public IDisposable? BeginScope<TState>(TState state) where TState : notnull => null;
/// <inheritdoc />
public bool IsEnabled(LogLevel logLevel) => true;
/// <inheritdoc />
public void Log<TState>(LogLevel logLevel, EventId eventId, TState state, Exception? exception,
Func<TState, Exception?, string> formatter)
{
if (logLevel == LogLevel.Warning) lock (_warnings) _warnings.Add(formatter(state, exception));
}
}