Joseph Doherty b61fe38823 fix(focas): browse-committed fixed-tree tags are readable (Gitea #540)
Authoring FOCAS tags through /raw -> Browse device... produced tags the driver
could never read. Every committed tag read BadNodeIdUnknown forever, and the
failure was silent end to end: the AdminUI accepted it, the deploy gate sealed
green, and the driver reported Healthy with 0 errors while ignoring the tags.
Net effect: the whole fixed-tree surface could not be published through any v3
authoring path. Found cutting wonder-app-vd03 over to v3 against a real Makino
Pro 5 / Fanuc 30i, where 0 of 20 committed tags read while two hand-authored
MACRO: tags on the same device read Good.

A captured browse leaf's id IS its DriverAttributeInfo.FullName, and the fixed
tree emitted "{deviceHost}/{path}" there -- an internal cache key, not an
address. Both authoring paths wrote it verbatim into TagConfig.address, and
FocasAddress.TryParse accepts no such form, so the driver skipped the tags at
init.

Fixed at the emitter rather than by stripping the host at commit, which fixes
the browse-commit flow and the manual picker's tree-select together and leaves
one canonical address form:

- FocasAddress gains a fourth kind, FIXED:<path>, and moves to Contracts so the
  AdminUI and ControlPlane can parse without referencing the runtime driver
  (#526). A FIXED: read is served from the fixed-tree snapshot the poll loop
  already maintains -- no area read, no connection. Writes refuse: nothing in
  that tree is a writable location on the CNC.
- The address carries no device. A tag's device comes from its Device row, and
  a second routing channel for one fact is what created this defect.
- An authored FIXED: tag arms the fixed-tree poll loop by itself. Enabled
  defaults false and the browser force-enables it only for a browse, so the
  operator would otherwise browse, commit, deploy, and land on a driver whose
  loop never starts -- every tag Bad with a correct address.
- Fixed-tree values are now dated from the last answered poll and go
  BadCommunicationError once it is stale (8 cadences, floored at 30s). The poll
  loop swallows a failed tick by design, so a dead CNC would otherwise serve its
  last snapshot as Good indefinitely -- harmless while nothing could bind to the
  tree, not harmless now.

Guardrails, so this class cannot recur silently:

- FocasTagConfigModel.Validate() runs the real parser instead of a non-empty
  check, and FocasTagDefinitionFactory.Inspect() warns at the deploy gate, which
  covers CSV/API config that never touches the modal.
- The manual picker offered axis/spindle/program/status "parameter groups" --
  none of which is a FOCAS addressing space -- and its own default value,
  axis:5, was unusable. It now composes PMC / PARAM: / MACRO: through
  FocasAddress, so what it emits is parseable by construction.

Tests assert addresses ROUND-TRIP through the parser rather than matching an
expected string: the previous FocasAddressBuilderTests pinned "axis:5" exactly,
which is how a green suite coexisted with a picker nobody could use. Verified
red-first against the old emitter. FOCAS 308, AdminUI 1095, ControlPlane 169,
Core 581 -- all pass, 0 warnings.

The remaining half of #540 -- a driver reporting Healthy/0 errors while
skipping tags at init -- is fleet-wide (eight drivers do this) and is filed
separately rather than patched per-driver.
2026-08-05 17:32:18 -04:00

147 lines
7.0 KiB
C#

namespace ZB.MOM.WW.OtOpcUa.Driver.FOCAS;
/// <summary>
/// Documented-API capability matrix — per CNC series, what ranges each addressed
/// <see cref="FocasAreaKind"/> supports. Authoritative source for the driver's
/// pre-flight validation in <see cref="FocasDriver.InitializeAsync"/>.
/// </summary>
/// <remarks>
/// <para>Ranges come from the Fanuc FOCAS Developer Kit documentation matrix
/// (see <c>docs/v2/focas-version-matrix.md</c> for the authoritative copy with
/// per-function citations). Numbers chosen to match what the FOCAS library
/// accepts — a read against an address outside the documented range returns
/// <c>EW_NUMBER</c> or <c>EW_PARAM</c> at the wire, which this driver maps to
/// BadOutOfRange. Catching at init time surfaces the mismatch as a config
/// error before any session is opened.</para>
/// <para><see cref="FocasCncSeries.Unknown"/> is treated permissively: every
/// address passes validation. Pre-matrix configs don't break on upgrade; new
/// deployments are encouraged to declare a series in the device options.</para>
/// </remarks>
public static class FocasCapabilityMatrix
{
/// <summary>
/// Validates whether an address is accepted by a CNC of the given series.
/// Returns null on pass, or a failure reason on reject.
/// </summary>
/// <param name="series">The CNC series to validate against.</param>
/// <param name="address">The address to validate.</param>
/// <returns>Null if valid, otherwise a failure reason string.</returns>
public static string? Validate(FocasCncSeries series, FocasAddress address)
{
if (series == FocasCncSeries.Unknown) return null;
return address.Kind switch
{
FocasAreaKind.Macro => ValidateMacro(series, address.Number),
FocasAreaKind.Parameter => ValidateParameter(series, address.Number),
FocasAreaKind.Pmc => ValidatePmc(series, address.PmcLetter, address.Number),
// Fixed-tree paths are not area reads, so there is no per-series numeric range to check.
// What a given CNC actually exposes there is discovered at runtime and capability-gated
// per subtree; a path this machine does not have resolves to BadNodeIdUnknown at read.
FocasAreaKind.Fixed => null,
_ => null,
};
}
/// <summary>Gets the macro variable number range accepted by a CNC series.</summary>
/// <param name="series">The CNC series.</param>
/// <returns>A tuple of (min, max) macro numbers.</returns>
internal static (int min, int max) MacroRange(FocasCncSeries series) => series switch
{
// Common macros 1-33 + 100-199 + 500-999 universally; extended 10000+ only on
// higher-end series. Using the extended ceiling per series per DevKit notes.
FocasCncSeries.Sixteen_i => (0, 999),
FocasCncSeries.Zero_i_D => (0, 999),
FocasCncSeries.Zero_i_F or
FocasCncSeries.Zero_i_MF or
FocasCncSeries.Zero_i_TF => (0, 9999),
FocasCncSeries.Thirty_i or
FocasCncSeries.ThirtyOne_i or
FocasCncSeries.ThirtyTwo_i => (0, 99999),
FocasCncSeries.PowerMotion_i => (0, 999),
_ => (0, int.MaxValue),
};
/// <summary>Gets the parameter number range accepted by a CNC series.</summary>
/// <param name="series">The CNC series.</param>
/// <returns>A tuple of (min, max) parameter numbers.</returns>
internal static (int min, int max) ParameterRange(FocasCncSeries series) => series switch
{
FocasCncSeries.Sixteen_i => (0, 9999),
FocasCncSeries.Zero_i_D or
FocasCncSeries.Zero_i_F or
FocasCncSeries.Zero_i_MF or
FocasCncSeries.Zero_i_TF => (0, 14999),
FocasCncSeries.Thirty_i or
FocasCncSeries.ThirtyOne_i or
FocasCncSeries.ThirtyTwo_i => (0, 29999),
FocasCncSeries.PowerMotion_i => (0, 29999),
_ => (0, int.MaxValue),
};
/// <summary>Gets the PMC letters accepted by a CNC series.</summary>
/// <param name="series">The CNC series.</param>
/// <returns>A set of accepted PMC letter strings.</returns>
internal static IReadOnlySet<string> PmcLetters(FocasCncSeries series) => series switch
{
FocasCncSeries.Sixteen_i => new HashSet<string>(StringComparer.OrdinalIgnoreCase) { "X", "Y", "R", "D" },
FocasCncSeries.Zero_i_D => new HashSet<string>(StringComparer.OrdinalIgnoreCase) { "X", "Y", "R", "D", "E", "A" },
FocasCncSeries.Zero_i_F or
FocasCncSeries.Zero_i_MF or
FocasCncSeries.Zero_i_TF => new HashSet<string>(StringComparer.OrdinalIgnoreCase) { "X", "Y", "F", "G", "R", "D", "E", "A", "M", "C" },
FocasCncSeries.Thirty_i or
FocasCncSeries.ThirtyOne_i or
FocasCncSeries.ThirtyTwo_i => new HashSet<string>(StringComparer.OrdinalIgnoreCase) { "X", "Y", "F", "G", "R", "D", "E", "A", "M", "C", "K", "T" },
FocasCncSeries.PowerMotion_i => new HashSet<string>(StringComparer.OrdinalIgnoreCase) { "X", "Y", "R", "D" },
_ => new HashSet<string>(StringComparer.OrdinalIgnoreCase),
};
/// <summary>Gets the maximum PMC address number for a CNC series.</summary>
/// <param name="series">The CNC series.</param>
/// <returns>The maximum address number.</returns>
internal static int PmcMaxNumber(FocasCncSeries series) => series switch
{
FocasCncSeries.Sixteen_i => 999,
FocasCncSeries.Zero_i_D => 1999,
FocasCncSeries.Zero_i_F or
FocasCncSeries.Zero_i_MF or
FocasCncSeries.Zero_i_TF => 9999,
FocasCncSeries.Thirty_i or
FocasCncSeries.ThirtyOne_i or
FocasCncSeries.ThirtyTwo_i => 59999,
FocasCncSeries.PowerMotion_i => 1999,
_ => int.MaxValue,
};
private static string? ValidateMacro(FocasCncSeries series, int number)
{
var (min, max) = MacroRange(series);
return (number < min || number > max)
? $"Macro variable #{number} is outside the documented range [{min}, {max}] for {series}."
: null;
}
private static string? ValidateParameter(FocasCncSeries series, int number)
{
var (min, max) = ParameterRange(series);
return (number < min || number > max)
? $"Parameter #{number} is outside the documented range [{min}, {max}] for {series}."
: null;
}
private static string? ValidatePmc(FocasCncSeries series, string? letter, int number)
{
if (string.IsNullOrEmpty(letter)) return "PMC address is missing its letter prefix.";
var letters = PmcLetters(series);
if (!letters.Contains(letter))
{
var letterList = string.Join(", ", letters);
return $"PMC letter '{letter}' is not supported on {series}. Accepted: {{{letterList}}}.";
}
var max = PmcMaxNumber(series);
return number > max
? $"PMC address {letter}{number} is outside the documented range [0, {max}] for {series}."
: null;
}
}