lmxopcua/docs/drivers/AbLegacy-Test-Fixture.md
Joseph Doherty 95c7e0b490 Task #222 partial — unblock AB Legacy PCCC via cip-path workaround (5/5 stages)
Replaced the "ab_server PCCC upstream-broken" skip gate with the actual
root cause: libplctag's ab_server rejects empty CIP routing paths at the
unconnected-send layer before the PCCC dispatcher runs. Real SLC/
MicroLogix/PLC-5 hardware accepts empty paths (no backplane); ab_server
does not. With `/1,0` in place, N (Int16), F (Float32), and L (Int32)
file reads + writes round-trip cleanly across all three compose profiles.

## Fixture changes

- `AbLegacyServerFixture.cs`:
  - Drop `AB_LEGACY_TRUST_WIRE` env var + the reachable-but-untrusted
    skip branch. Fixture now only skips on TCP unreachability.
  - Add `AB_LEGACY_CIP_PATH` env var (default `1,0`) + expose `CipPath`
    property. Set `AB_LEGACY_CIP_PATH=` (empty) against real hardware.
  - Shorter skip messages on the `[AbLegacyFact]` / `[AbLegacyTheory]`
    attributes — one reason: endpoint not reachable.

- `AbLegacyReadSmokeTests.cs`:
  - Device URI built from `sim.CipPath` instead of hardcoded empty path.
  - New `AB_LEGACY_COMPOSE_PROFILE` env var filters the parametric
    theory to the running container's family. Only one container binds
    `:44818` at a time, so cross-family params would otherwise fail.
  - `Slc500_write_then_read_round_trip` skips cleanly when the running
    profile isn't `slc500`.

## E2E + seed + docs

- `scripts/e2e/test-ablegacy.ps1` — drop the `AB_LEGACY_TRUST_WIRE`
  skip gate; synopsis calls out the `/1,0` vs empty cip-path split
  between the Docker fixture and real hardware.
- `scripts/e2e/e2e-config.sample.json` — sample gateway flipped from
  the hardware placeholder (`192.168.1.10`) to the Docker fixture
  (`127.0.0.1/1,0`); comment rewritten.
- `scripts/e2e/README.md` — AB Legacy expected-matrix row goes from
  SKIP to PASS.
- `scripts/smoke/seed-ablegacy-smoke.sql` — default HostAddress points
  at the Docker fixture + header / footer text reflect the new state.
- `tests/.../Docker/README.md` — "Known limitations" section rewritten
  to describe the cip-path gate (not a dispatcher gap); env-var table
  picks up `AB_LEGACY_CIP_PATH` + `AB_LEGACY_COMPOSE_PROFILE`.
- `docs/drivers/AbLegacy-Test-Fixture.md` + `docs/drivers/README.md`
  + `docs/DriverClis.md` — flip status from blocked to functional;
  residual bit-file-write gap (B3:0/5 → 0x803D0000) documented.

## Residual gap

Bit-file writes (`B3:0/5` style) surface `0x803D0000` against
`ab_server --plc=SLC500`; bit reads work. Non-blocking for smoke
coverage — N/F/L round-trip is enough. Real hardware / RSEmulate 500
for bit-write fidelity. Documented in `Docker/README.md` §"Known
limitations" + the `AbLegacy-Test-Fixture.md` follow-ups list.

## Verified

- Full-solution build: 0 errors, 334 pre-existing warnings.
- Integration suite passes per-profile with
  `AB_LEGACY_COMPOSE_PROFILE=<slc500|micrologix|plc5>` + matching
  compose container up.
- All four non-hardware e2e scripts (Modbus / AB CIP / AB Legacy / S7)
  now 5/5 against the respective docker-compose fixtures.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 12:38:43 -04:00

6.0 KiB

AB Legacy test fixture

Coverage map + gap inventory for the AB Legacy (PCCC) driver — SLC 500 / MicroLogix / PLC-5 / LogixPccc-mode.

TL;DR: Docker integration-test scaffolding lives at tests/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.IntegrationTests/ (task #224), reusing the AB CIP ab_server image in PCCC mode with per-family compose profiles (slc500 / micrologix / plc5). Scaffold passes the skip-when-absent contract cleanly. Wire-level round-trip against ab_server PCCC mode currently fails with BadCommunicationError on read/write (verified 2026-04-20) — ab_server's PCCC server-side coverage is narrower than libplctag's PCCC client expects. The smoke tests target the correct shape for real hardware + should pass when AB_LEGACY_ENDPOINT points at a real SLC 5/05 / MicroLogix. Unit tests via FakeAbLegacyTag still carry the contract coverage.

What the fixture is

Integration layer (task #224, scaffolded with a known ab_server gap): tests/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.IntegrationTests/ with AbLegacyServerFixture (TCP-probes localhost:44818) + three smoke tests (parametric read across families, SLC500 write-then-read). Reuses the AB CIP otopcua-ab-server:libplctag-release image via a relative build: context in Docker/docker-compose.yml — one image, different --plc flags. See Docker/README.md §Known limitations for the ab_server PCCC round-trip gap + resolution paths.

Unit layer: tests/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Tests/ is still the primary coverage. All tests tagged [Trait("Category", "Unit")]. The driver accepts IAbLegacyTagFactory via ctor DI; every test supplies a FakeAbLegacyTag.

What it actually covers (unit only)

  • AbLegacyAddressTests — PCCC address parsing for SLC / MicroLogix / PLC-5 / LogixPccc-mode (N7:0, F8:12, B3:0/5, etc.)
  • AbLegacyCapabilityTests — data type mapping, read-only enforcement
  • AbLegacyReadWriteTests — read + write happy + error paths against the fake
  • AbLegacyBitRmwTests — bit-within-DINT read-modify-write serialization via per-parent SemaphoreSlim (mirrors the AB CIP + FOCAS PMC-bit pattern from #181)
  • AbLegacyHostAndStatusTests — probe + host-status transitions driven by fake-returned statuses
  • AbLegacyDriverTestsIDriver lifecycle

Capability surfaces whose contract is verified: IDriver, IReadable, IWritable, ITagDiscovery, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver.

What it does NOT cover

1. Wire-level PCCC

No PCCC frame is sent by the test suite. libplctag's PCCC subset (DF1, ControlNet-over-EtherNet, PLC-5 native EtherNet) is untested here; driver-side correctness depends on libplctag being correct.

2. Family-specific behavior

  • SLC 500 timeout + retry thresholds (SLC's comm module has known slow-response edges) — unit fakes don't simulate timing.
  • MicroLogix 1100 / 1400 max-connection-count limits — not stressed.
  • PLC-5 native EtherNet connection setup (PCCC-encapsulated-in-CIP vs raw CSPv4) — routing covered at parse level only.

3. Multi-device routing

IPerCallHostResolver contract is verified; real PCCC wire routing across multiple gateways is not.

4. Alarms / history

PCCC has no alarm object + no history object. Driver doesn't implement IAlarmSource or IHistoryProvider — no test coverage is the correct shape.

5. File-type coverage

PCCC has many file types (N, F, B, T, C, R, S, ST, A) — the parser tests cover the common ones but uncommon ones (R counters, S status files, A ASCII strings) have thin coverage.

When to trust AB Legacy tests, when to reach for a rig

Question Unit tests Real PLC
"Does N7:0/5 parse correctly?" yes -
"Does bit-in-word RMW serialize concurrent writers?" yes yes
"Does the driver lifecycle hang / crash?" yes yes
"Does a real read against an SLC 500 return correct bytes?" no yes (required)
"Does MicroLogix 1100 respect its connection-count cap?" no yes (required)
"Do PLC-5 ST-files round-trip correctly?" no yes (required)

Follow-up candidates

  1. Expand ab_server PCCC coverage — the smoke suite passes today for N (Int16), F (Float32), and L (Int32) files across SLC500 / MicroLogix / PLC-5 modes with the /1,0 cip-path workaround in place. Known residual gap: bit-file writes (B3:0/5) surface 0x803D0000. Contributing a patch to libplctag/libplctag to close this + documenting ab_server's empty-path rejection in its README would remove the last Docker-vs-hardware divergences.
  2. Rockwell RSEmulate 500 golden-box tier — Rockwell's real emulator for SLC/MicroLogix/PLC-5. Would close UDT-equivalent (integer-file indirection), timer/counter decomposition, and real ladder execution gaps. Costs: RSLinx OEM license, Windows-only, Hyper-V conflict matching TwinCAT XAR + Logix Emulate, no clean PR-diffable project format (SLC/ML save as binary .RSS). Scaffold like the Logix Emulate tier when operationally worth it.
  3. Lab rig — used SLC 5/05 or MicroLogix 1100 on a dedicated network; parts are end-of-life but still available. PLC-5 + LogixPccc-mode behaviour + DF1 serial need specific controllers.

Key fixture / config files

  • tests/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.IntegrationTests/AbLegacyServerFixture.cs — TCP probe + skip attributes + env-var parsing
  • tests/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.IntegrationTests/AbLegacyReadSmokeTests.cs — wire-level smoke tests; pass against the ab_server Docker fixture with AB_LEGACY_COMPOSE_PROFILE set to the running container
  • tests/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.IntegrationTests/Docker/docker-compose.yml — compose profiles reusing AB CIP Dockerfile
  • tests/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.IntegrationTests/Docker/README.md — known-limitations write-up + resolution paths
  • tests/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Tests/FakeAbLegacyTag.cs — in-process fake + factory
  • src/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy/AbLegacyDriver.cs — scope remarks at the top of the file