Files
lmxopcua/tests
Joseph Doherty 9892a0253d Phase 3 PR 51 -- DL260 X-input FC02 discrete-input mapping end-to-end test. Integration test DL205XInputTests reads FC02 at the DirectLogicAddress.XInputToDiscrete-resolved address and asserts two behaviors against the dl205.json pymodbus profile: (1) X20 octal (=decimal 16 = Modbus DI 16) reads ON, proving the helper correctly octal-parses the trailing number and adds it to the 0 base; (2) X21 octal reads OFF (not exception) -- per docs/v2/dl205.md §I/O-mapping, 'reading a non-populated X input returns zero, not an exception' on DL260, because the CPU sizes the discrete-input table to the configured I/O not the installed hardware. Pymodbus models this by returning the default 0 value for any DI bit in the configured 'di size' range that wasn't explicitly seeded, matching real DL260 behaviour. Test uses X20 rather than X0 to sidestep a shared-blocks conflict: pymodbus places FC01/FC02 bit-address 0..15 into cell 0, but cell 0 is already uint16-typed (V0 marker = 0xCAFE) per the register-zero quirk test, and shared-blocks semantics allow only one type per cell. X20 octal = DI 16 lands in cell 1 which is free, so both the V0 quirk AND the X-input quirk can coexist in one profile. dl205.json: bits cell 1 seeded value=9 (bits 0 and 3 set -> X20, X23 octal = ON), write-range extended to include cell 1 (though X-inputs are read-only; the write-range entry is required by pymodbus for ANY cell referenced in a bits section even if only reads are expected -- pymodbus validates write-access uniformly). 10/10 DL205 integration tests pass with MODBUS_SIM_PROFILE=dl205. No driver code changes -- the XInputToDiscrete helper + FC02 read path already landed in PRs 50 and 21 respectively. This PR closes the integration-test gap that docs/v2/dl205.md called out under test name DL205_Xinput_unpopulated_reads_as_zero.
2026-04-18 22:25:13 -04:00
..
Phase 3 PR 28 — Admin UI cert-trust management page. New /certificates route (FleetAdmin-only) surfaces the OPC UA server's PKI store rejected + trusted certs and gives operators Trust / Delete / Revoke actions so rejected client certs can be promoted without touching disk. CertTrustService reads $PkiStoreRoot/{rejected,trusted}/certs/*.der files directly via X509CertificateLoader — no Opc.Ua dependency in the Admin project, which keeps the Admin host runnable on a machine that doesn't have the full Server install locally (only needs the shared PKI directory reachable; typical deployment has Admin + Server side-by-side on the same box and PkiStoreRoot defaults match so a plain-vanilla install needs no override). CertTrustOptions bound from the Admin's 'CertTrust:PkiStoreRoot' section, default %ProgramData%\OtOpcUa\pki (matches OpcUaServerOptions.PkiStoreRoot default). Trust action moves the .der from rejected/certs/ to trusted/certs/ via File.Move(overwrite:true) — idempotent, tolerates a concurrent operator doing the same move. Delete wipes the file. Revoke removes from trusted/certs/ (Opc.Ua re-reads the Directory store on each new client handshake, so no explicit reload signal is needed; operators retry the rejected connection after trusting). Thumbprint matching is case-insensitive because X509Certificate2.Thumbprint is upper-case hex but operators copy-paste from logs that sometimes lowercase it. Malformed files in the store are logged + skipped — a single bad .der can't take the whole management page offline. Missing store directories produce empty lists rather than exceptions so a pristine install (Server never run yet, no rejected/trusted dirs yet) doesn't crash the page.
2026-04-18 14:37:55 -04:00
Phase 3 PR 15 — alarm-condition contract in IAddressSpaceBuilder + wire OnAlarmEvent through GenericDriverNodeManager. IAddressSpaceBuilder.IVariableHandle gains MarkAsAlarmCondition(AlarmConditionInfo) which returns an IAlarmConditionSink. AlarmConditionInfo carries SourceName/InitialSeverity/InitialDescription. Concrete address-space builders (the upcoming PR 16 OPC UA server backend) materialize a sibling AlarmConditionState node on the first call; the sink receives every lifecycle transition the generic node manager forwards. GenericDriverNodeManager gains a CapturingBuilder wrapper that transparently wraps every Folder/Variable call — the wrapper observes MarkAsAlarmCondition calls without participating in materialization, captures the resulting IAlarmConditionSink into an internal source-node-id → sink ConcurrentDictionary keyed by IVariableHandle.FullReference. After DiscoverAsync completes, if the driver implements IAlarmSource the node manager subscribes to OnAlarmEvent and routes every AlarmEventArgs to the sink registered for args.SourceNodeId — unknown source ids are dropped silently (may belong to another driver or to a variable the builder chose not to flag). Dispose unsubscribes the forwarder to prevent dangling invocation-list references across node-manager rebuilds. GalaxyProxyDriver.DiscoverAsync now calls handle.MarkAsAlarmCondition(new AlarmConditionInfo(fullName, AlarmSeverity.Medium, null)) on every attr.IsAlarm=true variable — severity seed is Medium because the live Priority byte arrives through the subsequent GalaxyAlarmEvent stream (which PR 14's GalaxyAlarmTracker now emits); the Admin UI sees the severity update on the first transition. RecordingAddressSpaceBuilder in Driver.Galaxy.E2E gains a RecordedAlarmCondition list + a RecordingSink implementation that captures AlarmEventArgs for test assertion — the E2E parity suite can now verify alarm-condition registration shape in addition to folder/variable shape. Tests (4 new GenericDriverNodeManagerTests): Alarm_events_are_routed_to_the_sink_registered_for_the_matching_source_node_id — 2 alarms registered (Tank.HiHi + Heater.OverTemp), driver raises an event for Tank.HiHi, the Tank.HiHi sink captures the payload, the Heater.OverTemp sink does not (tag-scoped fan-out, not broadcast); Non_alarm_variables_do_not_register_sinks — plain Tank.Level in the same discover is not in TrackedAlarmSources; Unknown_source_node_id_is_dropped_silently — a transition for Unknown.Source doesn't reach any sink + no exception; Dispose_unsubscribes_from_OnAlarmEvent — post-dispose, a transition for a previously-registered tag is no-op because the forwarder detached. InternalsVisibleTo('ZB.MOM.WW.OtOpcUa.Core.Tests') added to Core csproj so TrackedAlarmSources internal property is visible to the test. Full solution: 0 errors, 152 unit tests pass (8 Core + 14 Proxy + 14 Admin + 24 Configuration + 6 Shared + 84 Galaxy.Host + 2 Server). PR 16 will implement the concrete OPC UA address-space builder that materializes AlarmConditionState from this contract.
2026-04-18 07:51:35 -04:00
Phase 3 PR 15 — alarm-condition contract in IAddressSpaceBuilder + wire OnAlarmEvent through GenericDriverNodeManager. IAddressSpaceBuilder.IVariableHandle gains MarkAsAlarmCondition(AlarmConditionInfo) which returns an IAlarmConditionSink. AlarmConditionInfo carries SourceName/InitialSeverity/InitialDescription. Concrete address-space builders (the upcoming PR 16 OPC UA server backend) materialize a sibling AlarmConditionState node on the first call; the sink receives every lifecycle transition the generic node manager forwards. GenericDriverNodeManager gains a CapturingBuilder wrapper that transparently wraps every Folder/Variable call — the wrapper observes MarkAsAlarmCondition calls without participating in materialization, captures the resulting IAlarmConditionSink into an internal source-node-id → sink ConcurrentDictionary keyed by IVariableHandle.FullReference. After DiscoverAsync completes, if the driver implements IAlarmSource the node manager subscribes to OnAlarmEvent and routes every AlarmEventArgs to the sink registered for args.SourceNodeId — unknown source ids are dropped silently (may belong to another driver or to a variable the builder chose not to flag). Dispose unsubscribes the forwarder to prevent dangling invocation-list references across node-manager rebuilds. GalaxyProxyDriver.DiscoverAsync now calls handle.MarkAsAlarmCondition(new AlarmConditionInfo(fullName, AlarmSeverity.Medium, null)) on every attr.IsAlarm=true variable — severity seed is Medium because the live Priority byte arrives through the subsequent GalaxyAlarmEvent stream (which PR 14's GalaxyAlarmTracker now emits); the Admin UI sees the severity update on the first transition. RecordingAddressSpaceBuilder in Driver.Galaxy.E2E gains a RecordedAlarmCondition list + a RecordingSink implementation that captures AlarmEventArgs for test assertion — the E2E parity suite can now verify alarm-condition registration shape in addition to folder/variable shape. Tests (4 new GenericDriverNodeManagerTests): Alarm_events_are_routed_to_the_sink_registered_for_the_matching_source_node_id — 2 alarms registered (Tank.HiHi + Heater.OverTemp), driver raises an event for Tank.HiHi, the Tank.HiHi sink captures the payload, the Heater.OverTemp sink does not (tag-scoped fan-out, not broadcast); Non_alarm_variables_do_not_register_sinks — plain Tank.Level in the same discover is not in TrackedAlarmSources; Unknown_source_node_id_is_dropped_silently — a transition for Unknown.Source doesn't reach any sink + no exception; Dispose_unsubscribes_from_OnAlarmEvent — post-dispose, a transition for a previously-registered tag is no-op because the forwarder detached. InternalsVisibleTo('ZB.MOM.WW.OtOpcUa.Core.Tests') added to Core csproj so TrackedAlarmSources internal property is visible to the test. Full solution: 0 errors, 152 unit tests pass (8 Core + 14 Proxy + 14 Admin + 24 Configuration + 6 Shared + 84 Galaxy.Host + 2 Server). PR 16 will implement the concrete OPC UA address-space builder that materializes AlarmConditionState from this contract.
2026-04-18 07:51:35 -04:00
Phase 1 Streams B–E scaffold + Phase 2 Streams A–C scaffold — 8 new projects with ~70 new tests, all green alongside the 494 v1 IntegrationTests baseline (parity preserved: no v1 tests broken; legacy OtOpcUa.Host untouched). Phase 1 finish: Configuration project (16 entities + 10 enums + DbContext + DesignTimeDbContextFactory + InitialSchema/StoredProcedures/AuthorizationGrants migrations — 8 procs including sp_PublishGeneration with MERGE on ExternalIdReservation per decision #124, sp_RollbackToGeneration cloning rows into a new published generation, sp_ValidateDraft with cross-cluster-namespace + EquipmentUuid-immutability + ZTag/SAPID reservation pre-flight, sp_ComputeGenerationDiff with CHECKSUM-based row signature — plus OtOpcUaNode/OtOpcUaAdmin SQL roles with EXECUTE grants scoped to per-principal-class proc sets and DENY UPDATE/DELETE/INSERT/SELECT on dbo schema); managed DraftValidator covering UNS segment regex, path length, EquipmentUuid immutability across generations, same-cluster namespace binding (decision #122), reservation pre-flight, EquipmentId derivation (decision #125), driver↔namespace compatibility — returning every failing rule in one pass; LiteDB local cache with round-trip + ring pruning + corruption-fast-fail; GenerationApplier with per-entity Added/Removed/Modified diff and dependency-ordered callbacks (namespace → driver → device → equipment → poll-group → tag, Removed before Added); Core project with GenericDriverNodeManager (scaffold for the Phase 2 Galaxy port) and DriverHost lifecycle registry; Server project using Microsoft.Extensions.Hosting BackgroundService replacing TopShelf, with NodeBootstrap that falls back to LiteDB cache when the central DB is unreachable (decision #79); Admin project scaffolded as Blazor Server with Bootstrap 5 sidebar layout, cookie auth, three admin roles (ConfigViewer/ConfigEditor/FleetAdmin), Cluster + Generation services fronting the stored procs. Phase 2 scaffold: Driver.Galaxy.Shared (netstandard2.0) with full MessagePack IPC contract surface — Hello version negotiation, Open/CloseSession, Heartbeat, DiscoverHierarchy + GalaxyObjectInfo/GalaxyAttributeInfo, Read/WriteValues, Subscribe/Unsubscribe/OnDataChange, AlarmSubscribe/Event/Ack, HistoryRead, HostConnectivityStatus, Recycle — plus length-prefixed framing (decision #28) with a 16 MiB cap and thread-safe FrameWriter/FrameReader; Driver.Galaxy.Host (net48) implementing the Tier C cross-cutting protections from driver-stability.md — strict PipeAcl (allow configured server SID only, explicit deny on LocalSystem + Administrators), PipeServer with caller-SID verification via pipe.RunAsClient + WindowsIdentity.GetCurrent and per-process shared-secret Hello, Galaxy-specific MemoryWatchdog (warn at max(1.5×baseline, +200 MB), soft-recycle at max(2×baseline, +200 MB), hard ceiling 1.5 GB, slope ≥5 MB/min over 30-min rolling window), RecyclePolicy (1 soft recycle per hour cap + 03:00 local daily scheduled), PostMortemMmf (1000-entry ring buffer in %ProgramData%\OtOpcUa\driver-postmortem\galaxy.mmf, survives hard crash, readable cross-process), MxAccessHandle : SafeHandle (ReleaseHandle loops Marshal.ReleaseComObject until refcount=0 then calls optional unregister callback), StaPump with responsiveness probe (BlockingCollection dispatcher for Phase 1 — real Win32 GetMessage/DispatchMessage pump slots in with the same semantics when the Galaxy code lift happens), IsExternalInit shim for init setters on .NET 4.8; Driver.Galaxy.Proxy (net10) implementing IDriver + ITagDiscovery forwarding over the IPC channel with MX data-type and security-classification mapping, plus Supervisor pieces — Backoff (5s → 15s → 60s capped, reset-on-stable-run), CircuitBreaker (3 crashes per 5 min opens; 1h → 4h → manual cooldown escalation; sticky alert doesn't auto-clear), HeartbeatMonitor (2s cadence, 3 consecutive misses = host dead per driver-stability.md). Infrastructure: docker SQL Server remapped to host port 14330 to coexist with the native MSSQL14 Galaxy ZB DB instance on 1433; NuGetAuditSuppress applied per-project for two System.Security.Cryptography.Xml advisories that only reach via EF Core Design with PrivateAssets=all (fix ships in 11.0.0-preview); .slnx gains 14 project registrations. Deferred with explicit TODOs in docs/v2/implementation/phase-2-partial-exit-evidence.md: Phase 1 Stream E Admin UI pages (Generations listing + draft-diff-publish, Equipment CRUD with OPC 40010 fields, UNS Areas/Lines tabs, ACLs + permission simulator, Generic JSON config editor, SignalR real-time, Release-Reservation + Merge-Equipment workflows, LDAP login page, AppServer smoke test per decision #142), Phase 2 Stream D (Galaxy MXAccess code lift out of legacy OtOpcUa.Host, dual-service installer, appsettings → DriverConfig migration script, legacy Host deletion — blocked by parity), Phase 2 Stream E (v1 IntegrationTests against v2 topology, Client.CLI walkthrough diff, four 2026-04-13 stability findings regression tests, adversarial review — requires live MXAccess runtime).
2026-04-17 21:35:25 -04:00
Phase 3 PR 51 -- DL260 X-input FC02 discrete-input mapping end-to-end test. Integration test DL205XInputTests reads FC02 at the DirectLogicAddress.XInputToDiscrete-resolved address and asserts two behaviors against the dl205.json pymodbus profile: (1) X20 octal (=decimal 16 = Modbus DI 16) reads ON, proving the helper correctly octal-parses the trailing number and adds it to the 0 base; (2) X21 octal reads OFF (not exception) -- per docs/v2/dl205.md §I/O-mapping, 'reading a non-populated X input returns zero, not an exception' on DL260, because the CPU sizes the discrete-input table to the configured I/O not the installed hardware. Pymodbus models this by returning the default 0 value for any DI bit in the configured 'di size' range that wasn't explicitly seeded, matching real DL260 behaviour. Test uses X20 rather than X0 to sidestep a shared-blocks conflict: pymodbus places FC01/FC02 bit-address 0..15 into cell 0, but cell 0 is already uint16-typed (V0 marker = 0xCAFE) per the register-zero quirk test, and shared-blocks semantics allow only one type per cell. X20 octal = DI 16 lands in cell 1 which is free, so both the V0 quirk AND the X-input quirk can coexist in one profile. dl205.json: bits cell 1 seeded value=9 (bits 0 and 3 set -> X20, X23 octal = ON), write-range extended to include cell 1 (though X-inputs are read-only; the write-range entry is required by pymodbus for ANY cell referenced in a bits section even if only reads are expected -- pymodbus validates write-access uniformly). 10/10 DL205 integration tests pass with MODBUS_SIM_PROFILE=dl205. No driver code changes -- the XInputToDiscrete helper + FC02 read path already landed in PRs 50 and 21 respectively. This PR closes the integration-test gap that docs/v2/dl205.md called out under test name DL205_Xinput_unpopulated_reads_as_zero.
2026-04-18 22:25:13 -04:00
Phase 3 PR 50 -- DL260 bit-memory address helpers (Y/C/X/SP) + live coil integration tests. Adds four new static helpers to DirectLogicAddress covering every discrete-memory bank on the DL260: YOutputToCoil (Y0=coil 2048), CRelayToCoil (C0=coil 3072), XInputToDiscrete (X0=DI 0), SpecialToDiscrete (SP0=DI 1024). Each helper takes the DirectLOGIC ladder-logic address (e.g. 'Y0', 'Y17', 'C1777') and adds the octal-decoded offset to the bank's Modbus base per the DL260 user manual's I/O-configuration chapter table. Uses the same 'octal-walk + reject 8/9' pattern as UserVMemoryToPdu so misaligned addresses fail loudly with a clear ArgumentException rather than silently hitting the wrong coil. Fixes a pymodbus-config bug surfaced during integration-test validation: dl205.json had bits entries at cell indices 2048 / 3072 / 4000, but pymodbus's ModbusSimulatorContext.validate divides bit addresses by 16 before indexing into the shared cell array -- so Modbus coil 2048 reads cell 128, not cell 2048. The sim was returning Illegal Data Address (exception 02) for every bit read in the Y/C/scratch range. Moved bits entries to cells 128 (Y bank marker = 0b101 for Y0=ON, Y1=OFF, Y2=ON), 192 (C bank marker = 0b101 for C0/C1/C2), 250 (scratch cell covering coils 4000..4015). write list updated to the correct cell addresses. Unit tests: YOutputToCoil theory sweep (Y0->2048, Y1->2049, Y7->2055, Y10->2056 octal-to-decimal, Y17->2063, Y777->2559 top of DL260 Y range), CRelayToCoil theory (C0->3072 through C1777->4095), XInputToDiscrete theory, SpecialToDiscrete theory (with case-insensitive 'SP' prefix). Bit_address_rejects_non_octal_digits (Y8/C9/X18), Bit_address_rejects_empty, accepts_lowercase_prefix, accepts_bare_octal_without_prefix. 48/48 Modbus.Tests pass. Integration tests: DL205CoilMappingTests with three facts -- DL260_Y0_maps_to_coil_2048 (FC01 at Y0 returns ON), DL260_C0_maps_to_coil_3072 (FC01 at C0 returns ON), DL260_scratch_Crelay_supports_write_then_read (FC05 write + FC01 read round-trip at coil 4000 proves the DL-mapped coil bank is fully read/write capable end-to-end). 9/9 DL205 integration tests pass against the pymodbus dl205 profile with MODBUS_SIM_PROFILE=dl205. Caller opts into the helpers per tag the same way as PR 47's V-memory helper -- pass DirectLogicAddress.YOutputToCoil("Y0") as the ModbusTagDefinition Address; no driver-wide DL-family flag. PR 51 adds the X-input read-side integration test (there's nothing to write since X-inputs are FC02 discrete inputs, read-only); PR 52 exception-code translation; PR 53 transport reconnect-on-drop since DL260 doesn't send TCP keepalives.
2026-04-18 22:22:42 -04:00