Joseph Doherty 94eec70fb0 fix(code-review): resolve Batch 3 wave A (OpcUaServer history/guard, ControlPlane topology gate)
- OpcUaServer-002: HistoryRead-Events NumValuesPerNode==0 now maps to unbounded (int.MaxValue) instead of the backend default-cap sentinel; no Core.Abstractions contract change (+EventMaxEvents helper tests)
- OpcUaServer-004: EnsureAddressSpaceCreated guard on public mutators -> clear InvalidOperationException instead of bare NRE if called pre-start (+tests)
- OpcUaServer-003: Deferred (endUtc inclusive/exclusive needs live Wonderware boundary confirmation)
- Configuration-013: wire DraftValidator.ValidateClusterTopology into AdminOperationsActor deploy gate (read-only, no migration) (+2 tests)