Files
lmxopcua/tests
Joseph Doherty 934909b430 fix(historian): #691 review — clamp Gateway at-or-after read, GoodNoData when nothing exists, HonorReturnBounds kill switch
1. The at-or-after bound read on a forward-only backend (Gateway) ends at
   now + ReverseRawReader.LookAhead instead of DateTime.MaxValue (the gateway
   only checks start <= end, so a year-9999 end reached AVEVA); a bound beyond
   the horizon is not found without a read. SqlServer/QuestDB keep MaxValue:
   they bind it safely and may hold samples further ahead. The Gateway fake now
   refuses far-future ends, so the missing-end-bound test is no longer vacuous.
3. No data and no bound found (whole read empty) => GoodNoData, no values —
   the pre-bounds answer (6.5.3.2: success only if one or both bounds exist).
   A one-value page whose start bound is missing first checks there is data or
   a found end bound.
4. ServerHistorian:HonorReturnBounds (default true); false ignores ReturnBounds
   as before #691, including the modified-read Bad_InvalidArgument.
2026-10-12 17:52:34 -04:00
..