90c1302f71
ClusterNode.AkkaPort and the node's own Cluster:Port are the same fact in two places and nothing made them agree. Phase 2 dials the row instead of gossiping, so a node binding 4054 while its row says 4053 becomes unreachable from central — and the symptom is a silent absence of acks rather than an error. That is the shape of the Modbus/ModbusTcp and TwinCat/Focas drifts already in this repo. Since Phase 1 also made the rows the deploy path's expected-ack set, drift already costs a failed deployment today. Implemented as the plan's preferred option: an admin-role singleton comparing rows against the membership an admin node can already see, rather than each driver node asserting its own row — Phase 4 removes the driver nodes' ConfigDb connection, so a self-assertion written there would have to be deleted again. Three shapes, split by severity: a row whose dial target disagrees with its own NodeId and a running node with no row are Errors; an enabled row with no matching member is a Warning, because a node down for maintenance is a legitimate state. Findings are logged only when the set changes — a check that reprints the same warning every sweep trains operators to filter it out. Documented limitation: Phase 2 must revisit this. Once the fleet splits into one mesh per cluster an admin node cannot see site members, and every site row would report EnabledRowNotInCluster forever. Sabotage: removing the change-detection guard turns the repeat test red. ControlPlane.Tests 100/100. Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW