cf9ce91e51
The first and only thing in the MTConnect workstream that exercises the driver
against a real Agent; everything else runs on canned XML.
Fixture (Docker/): two services, both stock images with this folder bind-mounted.
- `agent` mtconnect/agent:2.7.0.12 on :5000. NOTE the repo name: the source
project is mtconnect/cppagent but the PUBLISHED image is
mtconnect/agent; mtconnect/cppagent does not exist on Docker Hub.
- `adapter` a stdlib SHDR feeder. Required, not optional: the agent image ships
only the binary + schemas/styles, so a lone Agent answers /probe and
then reports every observation UNAVAILABLE forever, which can prove
nothing about reads or streaming.
Devices.xml seeds one DataItem per inference branch (SAMPLE+units, TIME_SERIES,
PART_COUNT/LINE_NUMBER, controlled vocab, DATA_SET, CONDITION), gives every named
item `name != id` (the inverse of the hand-authored unit fixtures), and leaves one
EVENT permanently unfed so UNAVAILABLE -> BadNoCommunication has a live subject.
Suite (12 tests) asserts STRUCTURALLY against the Agent's own /probe response, never
by literal id, so it survives an edit to Devices.xml and can be pointed at a real
machine tool via MTCONNECT_AGENT_ENDPOINT. It skips cleanly (12/12) when no Agent
answers, and each test carries a hard [Fact(Timeout)] so a half-up fixture cannot
wedge a build.
Three findings from bringing the fixture up, each now pinned in a comment:
- agent.cfg must be pure ASCII; one non-ASCII byte in a COMMENT makes the config
parser reject the whole file with a bare "Failed / Stopped at line: N" and exit.
- `sampleCount` is an attribute of a TIME_SERIES observation, not of a DataItem
declaration. A real Agent meeting one on a declaration DROPS THE ENTIRE DATA ITEM
from the device model, so the inference only ever sees null and a live TIME_SERIES
tag is always variable-length. Asserted, not ignored.
- The Agent's own <Agent> self-model publishes update-rate SAMPLEs that tick whether
or not any adapter is attached. Excluding them is load-bearing: with them included
the "live stream delivered a changed value" test passed with the fixture's data
source deliberately stopped.
MTConnectError-under-HTTP-200 is NOT covered live and cannot be: cppagent 2.7 answers
an unknown device 404 and an out-of-range sequence 400, each with a well-formed error
body. That shape stays canned-only, and the suite says so.
42 lines
1.9 KiB
XML
42 lines
1.9 KiB
XML
<Project Sdk="Microsoft.NET.Sdk">
|
|
|
|
<!-- OTOPCUA0001 (arch-review 07/C-1): this suite invokes driver capability methods DIRECTLY to
|
|
exercise wire-level behavior against a live Agent — the analyzer's documented intentional
|
|
case. Mirrors the NoWarn the MTConnect unit suite carries for the same reason. -->
|
|
<PropertyGroup>
|
|
<NoWarn>$(NoWarn);OTOPCUA0001</NoWarn>
|
|
</PropertyGroup>
|
|
|
|
<PropertyGroup>
|
|
<TargetFramework>net10.0</TargetFramework>
|
|
<Nullable>enable</Nullable>
|
|
<ImplicitUsings>enable</ImplicitUsings>
|
|
<IsPackable>false</IsPackable>
|
|
<IsTestProject>true</IsTestProject>
|
|
<RootNamespace>ZB.MOM.WW.OtOpcUa.Driver.MTConnect.IntegrationTests</RootNamespace>
|
|
</PropertyGroup>
|
|
|
|
<ItemGroup>
|
|
<PackageReference Include="xunit.v3"/>
|
|
<PackageReference Include="Shouldly"/>
|
|
<PackageReference Include="Microsoft.NET.Test.Sdk"/>
|
|
<PackageReference Include="xunit.runner.visualstudio">
|
|
<PrivateAssets>all</PrivateAssets>
|
|
<IncludeAssets>runtime; build; native; contentfiles; analyzers; buildtransitive</IncludeAssets>
|
|
</PackageReference>
|
|
</ItemGroup>
|
|
|
|
<ItemGroup>
|
|
<ProjectReference Include="..\..\..\src\Drivers\ZB.MOM.WW.OtOpcUa.Driver.MTConnect\ZB.MOM.WW.OtOpcUa.Driver.MTConnect.csproj"/>
|
|
<ProjectReference Include="..\..\..\src\Drivers\ZB.MOM.WW.OtOpcUa.Driver.MTConnect.Contracts\ZB.MOM.WW.OtOpcUa.Driver.MTConnect.Contracts.csproj"/>
|
|
</ItemGroup>
|
|
|
|
<!-- The fixture (compose + agent.cfg + Devices.xml + adapter.py) beside the test binaries, so
|
|
the skip message can point at a compose file that is actually next to the runner — the
|
|
same convention the Modbus / S7 / AB fixtures use. -->
|
|
<ItemGroup>
|
|
<None Update="Docker\**\*" CopyToOutputDirectory="PreserveNewest"/>
|
|
</ItemGroup>
|
|
|
|
</Project>
|