Joseph Doherty b61fe38823 fix(focas): browse-committed fixed-tree tags are readable (Gitea #540)
Authoring FOCAS tags through /raw -> Browse device... produced tags the driver
could never read. Every committed tag read BadNodeIdUnknown forever, and the
failure was silent end to end: the AdminUI accepted it, the deploy gate sealed
green, and the driver reported Healthy with 0 errors while ignoring the tags.
Net effect: the whole fixed-tree surface could not be published through any v3
authoring path. Found cutting wonder-app-vd03 over to v3 against a real Makino
Pro 5 / Fanuc 30i, where 0 of 20 committed tags read while two hand-authored
MACRO: tags on the same device read Good.

A captured browse leaf's id IS its DriverAttributeInfo.FullName, and the fixed
tree emitted "{deviceHost}/{path}" there -- an internal cache key, not an
address. Both authoring paths wrote it verbatim into TagConfig.address, and
FocasAddress.TryParse accepts no such form, so the driver skipped the tags at
init.

Fixed at the emitter rather than by stripping the host at commit, which fixes
the browse-commit flow and the manual picker's tree-select together and leaves
one canonical address form:

- FocasAddress gains a fourth kind, FIXED:<path>, and moves to Contracts so the
  AdminUI and ControlPlane can parse without referencing the runtime driver
  (#526). A FIXED: read is served from the fixed-tree snapshot the poll loop
  already maintains -- no area read, no connection. Writes refuse: nothing in
  that tree is a writable location on the CNC.
- The address carries no device. A tag's device comes from its Device row, and
  a second routing channel for one fact is what created this defect.
- An authored FIXED: tag arms the fixed-tree poll loop by itself. Enabled
  defaults false and the browser force-enables it only for a browse, so the
  operator would otherwise browse, commit, deploy, and land on a driver whose
  loop never starts -- every tag Bad with a correct address.
- Fixed-tree values are now dated from the last answered poll and go
  BadCommunicationError once it is stale (8 cadences, floored at 30s). The poll
  loop swallows a failed tick by design, so a dead CNC would otherwise serve its
  last snapshot as Good indefinitely -- harmless while nothing could bind to the
  tree, not harmless now.

Guardrails, so this class cannot recur silently:

- FocasTagConfigModel.Validate() runs the real parser instead of a non-empty
  check, and FocasTagDefinitionFactory.Inspect() warns at the deploy gate, which
  covers CSV/API config that never touches the modal.
- The manual picker offered axis/spindle/program/status "parameter groups" --
  none of which is a FOCAS addressing space -- and its own default value,
  axis:5, was unusable. It now composes PMC / PARAM: / MACRO: through
  FocasAddress, so what it emits is parseable by construction.

Tests assert addresses ROUND-TRIP through the parser rather than matching an
expected string: the previous FocasAddressBuilderTests pinned "axis:5" exactly,
which is how a green suite coexisted with a picker nobody could use. Verified
red-first against the old emitter. FOCAS 308, AdminUI 1095, ControlPlane 169,
Core 581 -- all pass, 0 warnings.

The remaining half of #540 -- a driver reporting Healthy/0 errors while
skipping tags at init -- is fleet-wide (eight drivers do this) and is filed
separately rather than patched per-driver.
2026-08-05 17:32:18 -04:00
..