Joseph Doherty f53c39a598 Phase 3 PR 16 — concrete OPC UA server scaffolding with AlarmConditionState materialization. Introduces the OPCFoundation.NetStandard.Opc.Ua.Server package (v1.5.374.126, same version the v1 stack already uses) and two new server-side classes: DriverNodeManager : CustomNodeManager2 is the concrete realization of PR 15's IAddressSpaceBuilder contract — Folder() creates FolderState nodes under an Organizes hierarchy rooted at ObjectsFolder > DriverInstanceId; Variable() creates BaseDataVariableState with DataType mapped from DriverDataType (Boolean/Int32/Float/Double/String/DateTime) + ValueRank (Scalar or OneDimension) + AccessLevel CurrentReadOrWrite; AddProperty() creates PropertyState with HasProperty reference. Read hook wires OnReadValue per variable to route to IReadable.ReadAsync; Write hook wires OnWriteValue to route to IWritable.WriteAsync and surface per-tag StatusCode. MarkAsAlarmCondition() materializes an OPC UA AlarmConditionState child of the variable, seeded from AlarmConditionInfo (SourceName, InitialSeverity → UA severity via Low=250/Medium=500/High=700/Critical=900, InitialDescription), initial state Enabled + Acknowledged + Inactive + Retain=false. Returns an IAlarmConditionSink whose OnTransition updates alarm.Severity/Time/Message and switches state per AlarmType string ('Active' → SetActiveState(true) + SetAcknowledgedState(false) + Retain=true; 'Acknowledged' → SetAcknowledgedState(true); 'Inactive' → SetActiveState(false) + Retain=false if already Acked) then calls alarm.ReportEvent to emit the OPC UA event to subscribed clients. Galaxy's GalaxyAlarmTracker (PR 14) now lands at a concrete AlarmConditionState node instead of just raising an unobserved C# event. OtOpcUaServer : StandardServer wires one DriverNodeManager per DriverHost.GetDriver during CreateMasterNodeManager — anonymous endpoint, no security profile (minimum-viable; LDAP + security-profile wire-up is the next PR). DriverHost gains public GetDriver(instanceId) so the server can enumerate drivers at startup. NestedBuilder inner class in DriverNodeManager implements IAddressSpaceBuilder by temporarily retargeting the parent's _currentFolder during each call so Folder→Variable→AddProperty land under the correct subtree — not thread-safe if discovery ran concurrently, but GenericDriverNodeManager.BuildAddressSpaceAsync is sequential per driver so this is safe by construction. NuGet audit suppress for GHSA-h958-fxgg-g7w3 (moderate-severity in OPCFoundation.NetStandard.Opc.Ua.Core 1.5.374.126; v1 stack already accepts this risk on the same package version). PR 16 is scoped as scaffolding — the actual server startup (ApplicationInstance, certificate config, endpoint binding, session management wiring into OpcUaServerService.ExecuteAsync) is deferred to a follow-up PR because it needs ApplicationConfiguration XML + optional-cert-store logic that depends on per-deployment policy decisions. The materialization shape is complete: a subsequent PR adds 100 LOC to start the server and all the already-written IAddressSpaceBuilder + alarm-condition + read/write wire-up activates end-to-end. Full solution: 0 errors, 152 unit tests pass (no new tests this PR — DriverNodeManager unit testing needs an IServerInternal mock which is heavyweight; live-endpoint integration tests land alongside the server-startup PR).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-18 08:00:36 -04:00
..
Phase 3 PR 16 — concrete OPC UA server scaffolding with AlarmConditionState materialization. Introduces the OPCFoundation.NetStandard.Opc.Ua.Server package (v1.5.374.126, same version the v1 stack already uses) and two new server-side classes: DriverNodeManager : CustomNodeManager2 is the concrete realization of PR 15's IAddressSpaceBuilder contract — Folder() creates FolderState nodes under an Organizes hierarchy rooted at ObjectsFolder > DriverInstanceId; Variable() creates BaseDataVariableState with DataType mapped from DriverDataType (Boolean/Int32/Float/Double/String/DateTime) + ValueRank (Scalar or OneDimension) + AccessLevel CurrentReadOrWrite; AddProperty() creates PropertyState with HasProperty reference. Read hook wires OnReadValue per variable to route to IReadable.ReadAsync; Write hook wires OnWriteValue to route to IWritable.WriteAsync and surface per-tag StatusCode. MarkAsAlarmCondition() materializes an OPC UA AlarmConditionState child of the variable, seeded from AlarmConditionInfo (SourceName, InitialSeverity → UA severity via Low=250/Medium=500/High=700/Critical=900, InitialDescription), initial state Enabled + Acknowledged + Inactive + Retain=false. Returns an IAlarmConditionSink whose OnTransition updates alarm.Severity/Time/Message and switches state per AlarmType string ('Active' → SetActiveState(true) + SetAcknowledgedState(false) + Retain=true; 'Acknowledged' → SetAcknowledgedState(true); 'Inactive' → SetActiveState(false) + Retain=false if already Acked) then calls alarm.ReportEvent to emit the OPC UA event to subscribed clients. Galaxy's GalaxyAlarmTracker (PR 14) now lands at a concrete AlarmConditionState node instead of just raising an unobserved C# event. OtOpcUaServer : StandardServer wires one DriverNodeManager per DriverHost.GetDriver during CreateMasterNodeManager — anonymous endpoint, no security profile (minimum-viable; LDAP + security-profile wire-up is the next PR). DriverHost gains public GetDriver(instanceId) so the server can enumerate drivers at startup. NestedBuilder inner class in DriverNodeManager implements IAddressSpaceBuilder by temporarily retargeting the parent's _currentFolder during each call so Folder→Variable→AddProperty land under the correct subtree — not thread-safe if discovery ran concurrently, but GenericDriverNodeManager.BuildAddressSpaceAsync is sequential per driver so this is safe by construction. NuGet audit suppress for GHSA-h958-fxgg-g7w3 (moderate-severity in OPCFoundation.NetStandard.Opc.Ua.Core 1.5.374.126; v1 stack already accepts this risk on the same package version). PR 16 is scoped as scaffolding — the actual server startup (ApplicationInstance, certificate config, endpoint binding, session management wiring into OpcUaServerService.ExecuteAsync) is deferred to a follow-up PR because it needs ApplicationConfiguration XML + optional-cert-store logic that depends on per-deployment policy decisions. The materialization shape is complete: a subsequent PR adds 100 LOC to start the server and all the already-written IAddressSpaceBuilder + alarm-condition + read/write wire-up activates end-to-end. Full solution: 0 errors, 152 unit tests pass (no new tests this PR — DriverNodeManager unit testing needs an IServerInternal mock which is heavyweight; live-endpoint integration tests land alongside the server-startup PR).
2026-04-18 08:00:36 -04:00
Phase 3 PR 15 — alarm-condition contract in IAddressSpaceBuilder + wire OnAlarmEvent through GenericDriverNodeManager. IAddressSpaceBuilder.IVariableHandle gains MarkAsAlarmCondition(AlarmConditionInfo) which returns an IAlarmConditionSink. AlarmConditionInfo carries SourceName/InitialSeverity/InitialDescription. Concrete address-space builders (the upcoming PR 16 OPC UA server backend) materialize a sibling AlarmConditionState node on the first call; the sink receives every lifecycle transition the generic node manager forwards. GenericDriverNodeManager gains a CapturingBuilder wrapper that transparently wraps every Folder/Variable call — the wrapper observes MarkAsAlarmCondition calls without participating in materialization, captures the resulting IAlarmConditionSink into an internal source-node-id → sink ConcurrentDictionary keyed by IVariableHandle.FullReference. After DiscoverAsync completes, if the driver implements IAlarmSource the node manager subscribes to OnAlarmEvent and routes every AlarmEventArgs to the sink registered for args.SourceNodeId — unknown source ids are dropped silently (may belong to another driver or to a variable the builder chose not to flag). Dispose unsubscribes the forwarder to prevent dangling invocation-list references across node-manager rebuilds. GalaxyProxyDriver.DiscoverAsync now calls handle.MarkAsAlarmCondition(new AlarmConditionInfo(fullName, AlarmSeverity.Medium, null)) on every attr.IsAlarm=true variable — severity seed is Medium because the live Priority byte arrives through the subsequent GalaxyAlarmEvent stream (which PR 14's GalaxyAlarmTracker now emits); the Admin UI sees the severity update on the first transition. RecordingAddressSpaceBuilder in Driver.Galaxy.E2E gains a RecordedAlarmCondition list + a RecordingSink implementation that captures AlarmEventArgs for test assertion — the E2E parity suite can now verify alarm-condition registration shape in addition to folder/variable shape. Tests (4 new GenericDriverNodeManagerTests): Alarm_events_are_routed_to_the_sink_registered_for_the_matching_source_node_id — 2 alarms registered (Tank.HiHi + Heater.OverTemp), driver raises an event for Tank.HiHi, the Tank.HiHi sink captures the payload, the Heater.OverTemp sink does not (tag-scoped fan-out, not broadcast); Non_alarm_variables_do_not_register_sinks — plain Tank.Level in the same discover is not in TrackedAlarmSources; Unknown_source_node_id_is_dropped_silently — a transition for Unknown.Source doesn't reach any sink + no exception; Dispose_unsubscribes_from_OnAlarmEvent — post-dispose, a transition for a previously-registered tag is no-op because the forwarder detached. InternalsVisibleTo('ZB.MOM.WW.OtOpcUa.Core.Tests') added to Core csproj so TrackedAlarmSources internal property is visible to the test. Full solution: 0 errors, 152 unit tests pass (8 Core + 14 Proxy + 14 Admin + 24 Configuration + 6 Shared + 84 Galaxy.Host + 2 Server). PR 16 will implement the concrete OPC UA address-space builder that materializes AlarmConditionState from this contract.
2026-04-18 07:51:35 -04:00
Phase 3 PR 15 — alarm-condition contract in IAddressSpaceBuilder + wire OnAlarmEvent through GenericDriverNodeManager. IAddressSpaceBuilder.IVariableHandle gains MarkAsAlarmCondition(AlarmConditionInfo) which returns an IAlarmConditionSink. AlarmConditionInfo carries SourceName/InitialSeverity/InitialDescription. Concrete address-space builders (the upcoming PR 16 OPC UA server backend) materialize a sibling AlarmConditionState node on the first call; the sink receives every lifecycle transition the generic node manager forwards. GenericDriverNodeManager gains a CapturingBuilder wrapper that transparently wraps every Folder/Variable call — the wrapper observes MarkAsAlarmCondition calls without participating in materialization, captures the resulting IAlarmConditionSink into an internal source-node-id → sink ConcurrentDictionary keyed by IVariableHandle.FullReference. After DiscoverAsync completes, if the driver implements IAlarmSource the node manager subscribes to OnAlarmEvent and routes every AlarmEventArgs to the sink registered for args.SourceNodeId — unknown source ids are dropped silently (may belong to another driver or to a variable the builder chose not to flag). Dispose unsubscribes the forwarder to prevent dangling invocation-list references across node-manager rebuilds. GalaxyProxyDriver.DiscoverAsync now calls handle.MarkAsAlarmCondition(new AlarmConditionInfo(fullName, AlarmSeverity.Medium, null)) on every attr.IsAlarm=true variable — severity seed is Medium because the live Priority byte arrives through the subsequent GalaxyAlarmEvent stream (which PR 14's GalaxyAlarmTracker now emits); the Admin UI sees the severity update on the first transition. RecordingAddressSpaceBuilder in Driver.Galaxy.E2E gains a RecordedAlarmCondition list + a RecordingSink implementation that captures AlarmEventArgs for test assertion — the E2E parity suite can now verify alarm-condition registration shape in addition to folder/variable shape. Tests (4 new GenericDriverNodeManagerTests): Alarm_events_are_routed_to_the_sink_registered_for_the_matching_source_node_id — 2 alarms registered (Tank.HiHi + Heater.OverTemp), driver raises an event for Tank.HiHi, the Tank.HiHi sink captures the payload, the Heater.OverTemp sink does not (tag-scoped fan-out, not broadcast); Non_alarm_variables_do_not_register_sinks — plain Tank.Level in the same discover is not in TrackedAlarmSources; Unknown_source_node_id_is_dropped_silently — a transition for Unknown.Source doesn't reach any sink + no exception; Dispose_unsubscribes_from_OnAlarmEvent — post-dispose, a transition for a previously-registered tag is no-op because the forwarder detached. InternalsVisibleTo('ZB.MOM.WW.OtOpcUa.Core.Tests') added to Core csproj so TrackedAlarmSources internal property is visible to the test. Full solution: 0 errors, 152 unit tests pass (8 Core + 14 Proxy + 14 Admin + 24 Configuration + 6 Shared + 84 Galaxy.Host + 2 Server). PR 16 will implement the concrete OPC UA address-space builder that materializes AlarmConditionState from this contract.