Joseph Doherty 238748bc98 Phase 3 PR 67 -- OPC UA Client IReadable + IWritable via Session.ReadAsync/WriteAsync. Adds IReadable + IWritable capabilities to OpcUaClientDriver, routing reads/writes through the session's non-obsolete ReadAsync(RequestHeader, maxAge, TimestampsToReturn, ReadValueIdCollection, ct) and WriteAsync(RequestHeader, WriteValueCollection, ct) overloads (the sync and BeginXxx/EndXxx patterns are all [Obsolete] in SDK 1.5.378). Serializes on the shared Gate from PR 66 so reads + writes + future subscribe + probe don't race on the single session. NodeId parsing: fullReferences use OPC UA's standard serialized NodeId form -- ns=2;s=Demo.Counter, i=2253, ns=4;g=... for GUID, ns=3;b=... for opaque. TryParseNodeId calls NodeId.Parse with the session's MessageContext which honours the server-negotiated namespace URI table. Malformed input surfaces as BadNodeIdInvalid (0x80330000) WITHOUT a wire round-trip -- saves a request for a fault the driver can detect locally. Cascading-quality implementation per driver-specs.md \u00A78: upstream StatusCode, SourceTimestamp, and ServerTimestamp pass through VERBATIM. Bad codes from the remote server stay as the same Bad code (not translated to generic BadInternalError) so downstream clients can distinguish 'upstream value unavailable' from 'local driver bug'. SourceTimestamp is preserved verbatim (null on MinValue guard) so staleness is visible; ServerTimestamp falls back to DateTime.UtcNow if the upstream omitted it, never overwriting a non-zero value. Wire-level exceptions in the Read batch -- transport / timeout / session-dropped -- fan out BadCommunicationError (0x80050000) across every tag in the batch, not BadInternalError, so operators distinguish network reachability from driver faults. Write-side same pattern: successful WriteAsync maps each upstream StatusCode.Code verbatim into the local WriteResult.StatusCode; transport-layer failure fans out BadCommunicationError across the whole batch. WriteValue carries AttributeId=Value + DataValue wrapping Variant(writeValue) -- the SDK handles the type-to-Variant mapping for common CLR types (bool, int, float, string, etc.) so the driver doesn't need a per-type switch. Name disambiguation: the SDK has its own Opc.Ua.WriteRequest type which collides with ZB.MOM.WW.OtOpcUa.Core.Abstractions.WriteRequest; method signature uses the fully-qualified Core.Abstractions.WriteRequest. Unit tests (OpcUaClientReadWriteTests, 2 facts): ReadAsync_without_initialize_throws_InvalidOperationException + WriteAsync_without_initialize_throws_InvalidOperationException -- pre-init calls hit RequireSession and fail uniformly. Wire-level round-trip coverage against a live remote server lands in a follow-up PR once we scaffold an in-process OPC UA server fixture (the existing Server project in the solution is a candidate host). 7/7 OpcUaClient.Tests pass (5 scaffold + 2 read/write). dotnet build clean. Scope: ITagDiscovery (browse) + ISubscribable + IHostConnectivityProbe remain deferred to PRs 68-69 which also need namespace-index remapping and reference-counted MonitoredItem forwarding per driver-specs.md \u00A78.
2026-04-19 01:13:34 -04:00
..
Phase 3 PR 66 -- OPC UA Client (gateway) driver project scaffold + IDriver session lifecycle. First driver that CONSUMES OPC UA rather than PUBLISHES it -- connects to a remote server and re-exposes its address space through the local OtOpcUa server per driver-specs.md \u00A78. Uses the same OPCFoundation.NetStandard.Opc.Ua.Client package the existing Client.Shared ships (bumped to 1.5.378.106 to match). Builds its own ApplicationConfiguration (cert stores under %LocalAppData%/OtOpcUa/pki so multiple driver instances in one OtOpcUa server process share a trust anchor) rather than reusing Client.Shared -- Client.Shared is oriented at the interactive CLI with different session-lifetime needs (this driver is always-on, needs keep-alive + session transfer on reconnect + multi-year uptime). Navigated the post-refactor 1.5.378 SDK surface: every Session.Create* static is now [Obsolete] in favour of DefaultSessionFactory; CoreClientUtils.SelectEndpoint got the sync overloads deprecated in favour of SelectEndpointAsync with a required ITelemetryContext parameter. Driver passes telemetry: null! to both SelectEndpointAsync + new DefaultSessionFactory(telemetry: null!) -- the SDK's internal default sink handles null gracefully and plumbing a telemetry context through the driver options surface is out of scope (the driver emits its own logs via the DriverHealth surface anyway). ApplicationInstance default ctor is also obsolete; wrapped in #pragma warning disable CS0618 rather than migrate to the ITelemetryContext overload for the same reason. OpcUaClientDriverOptions models driver-specs.md \u00A78 settings: EndpointUrl (default opc.tcp://localhost:4840 IANA-assigned port), SecurityPolicy/SecurityMode/AuthType enums, Username/Password, SessionTimeout=120s + KeepAliveInterval=5s + ReconnectPeriod=5s (defaults from spec), AutoAcceptCertificates=false (production default; dev turns on for self-signed servers), ApplicationUri + SessionName knobs for certificate SAN matching and remote-server session-list identification. OpcUaClientDriver : IDriver: InitializeAsync builds the ApplicationConfiguration, resolves + creates cert if missing via app.CheckApplicationInstanceCertificatesAsync, selects endpoint via CoreClientUtils.SelectEndpointAsync, builds UserIdentity (Anonymous or Username with UTF-8-encoded password bytes -- the legacy string-password ctor went away; Certificate auth deferred), creates session via DefaultSessionFactory.CreateAsync. Health transitions Unknown -> Initializing -> Healthy on success or -> Faulted on failure with best-effort Session.CloseAsync cleanup. ShutdownAsync (async now, not Task.CompletedTask) closes the session + disposes. Internal Session + Gate expose to the test project via InternalsVisibleTo so PRs 67-69 can stack read/write/discovery/subscribe on the same serialization. Scaffold tests (OpcUaClientDriverScaffoldTests, 5 facts): Default_options_target_standard_opcua_port_and_anonymous_auth (4840 + None mode + Anonymous + AutoAccept=false production default), Default_timeouts_match_driver_specs_section_8 (120s/5s/5s), Driver_reports_type_and_id_before_connect (DriverType=OpcUaClient, DriverInstanceId round-trip, pre-init Unknown health), Initialize_against_unreachable_endpoint_transitions_to_Faulted_and_throws, Reinitialize_against_unreachable_endpoint_re_throws. Uses opc.tcp://127.0.0.1:1 as the 'guaranteed-unreachable' target -- RFC 5737 reserved IPs get black-holed and time out only after the SDK's internal retry/backoff fully elapses (~60s), while port 1 on loopback refuses immediately with TCP RST which keeps the test suite snappy (5 tests / 8s). 5/5 pass. dotnet build clean. Scope boundary: ITagDiscovery / IReadable / IWritable / ISubscribable / IHostConnectivityProbe deliberately NOT in this PR -- they need browse + namespace remapping + reference-counted MonitoredItem forwarding + keep-alive probing and land in PRs 67-69.
2026-04-19 01:07:57 -04:00
Phase 3 PR 67 -- OPC UA Client IReadable + IWritable via Session.ReadAsync/WriteAsync. Adds IReadable + IWritable capabilities to OpcUaClientDriver, routing reads/writes through the session's non-obsolete ReadAsync(RequestHeader, maxAge, TimestampsToReturn, ReadValueIdCollection, ct) and WriteAsync(RequestHeader, WriteValueCollection, ct) overloads (the sync and BeginXxx/EndXxx patterns are all [Obsolete] in SDK 1.5.378). Serializes on the shared Gate from PR 66 so reads + writes + future subscribe + probe don't race on the single session. NodeId parsing: fullReferences use OPC UA's standard serialized NodeId form -- ns=2;s=Demo.Counter, i=2253, ns=4;g=... for GUID, ns=3;b=... for opaque. TryParseNodeId calls NodeId.Parse with the session's MessageContext which honours the server-negotiated namespace URI table. Malformed input surfaces as BadNodeIdInvalid (0x80330000) WITHOUT a wire round-trip -- saves a request for a fault the driver can detect locally. Cascading-quality implementation per driver-specs.md \u00A78: upstream StatusCode, SourceTimestamp, and ServerTimestamp pass through VERBATIM. Bad codes from the remote server stay as the same Bad code (not translated to generic BadInternalError) so downstream clients can distinguish 'upstream value unavailable' from 'local driver bug'. SourceTimestamp is preserved verbatim (null on MinValue guard) so staleness is visible; ServerTimestamp falls back to DateTime.UtcNow if the upstream omitted it, never overwriting a non-zero value. Wire-level exceptions in the Read batch -- transport / timeout / session-dropped -- fan out BadCommunicationError (0x80050000) across every tag in the batch, not BadInternalError, so operators distinguish network reachability from driver faults. Write-side same pattern: successful WriteAsync maps each upstream StatusCode.Code verbatim into the local WriteResult.StatusCode; transport-layer failure fans out BadCommunicationError across the whole batch. WriteValue carries AttributeId=Value + DataValue wrapping Variant(writeValue) -- the SDK handles the type-to-Variant mapping for common CLR types (bool, int, float, string, etc.) so the driver doesn't need a per-type switch. Name disambiguation: the SDK has its own Opc.Ua.WriteRequest type which collides with ZB.MOM.WW.OtOpcUa.Core.Abstractions.WriteRequest; method signature uses the fully-qualified Core.Abstractions.WriteRequest. Unit tests (OpcUaClientReadWriteTests, 2 facts): ReadAsync_without_initialize_throws_InvalidOperationException + WriteAsync_without_initialize_throws_InvalidOperationException -- pre-init calls hit RequireSession and fail uniformly. Wire-level round-trip coverage against a live remote server lands in a follow-up PR once we scaffold an in-process OPC UA server fixture (the existing Server project in the solution is a candidate host). 7/7 OpcUaClient.Tests pass (5 scaffold + 2 read/write). dotnet build clean. Scope: ITagDiscovery (browse) + ISubscribable + IHostConnectivityProbe remain deferred to PRs 68-69 which also need namespace-index remapping and reference-counted MonitoredItem forwarding per driver-specs.md \u00A78.
2026-04-19 01:13:34 -04:00
Phase 3 PR 66 -- OPC UA Client (gateway) driver project scaffold + IDriver session lifecycle. First driver that CONSUMES OPC UA rather than PUBLISHES it -- connects to a remote server and re-exposes its address space through the local OtOpcUa server per driver-specs.md \u00A78. Uses the same OPCFoundation.NetStandard.Opc.Ua.Client package the existing Client.Shared ships (bumped to 1.5.378.106 to match). Builds its own ApplicationConfiguration (cert stores under %LocalAppData%/OtOpcUa/pki so multiple driver instances in one OtOpcUa server process share a trust anchor) rather than reusing Client.Shared -- Client.Shared is oriented at the interactive CLI with different session-lifetime needs (this driver is always-on, needs keep-alive + session transfer on reconnect + multi-year uptime). Navigated the post-refactor 1.5.378 SDK surface: every Session.Create* static is now [Obsolete] in favour of DefaultSessionFactory; CoreClientUtils.SelectEndpoint got the sync overloads deprecated in favour of SelectEndpointAsync with a required ITelemetryContext parameter. Driver passes telemetry: null! to both SelectEndpointAsync + new DefaultSessionFactory(telemetry: null!) -- the SDK's internal default sink handles null gracefully and plumbing a telemetry context through the driver options surface is out of scope (the driver emits its own logs via the DriverHealth surface anyway). ApplicationInstance default ctor is also obsolete; wrapped in #pragma warning disable CS0618 rather than migrate to the ITelemetryContext overload for the same reason. OpcUaClientDriverOptions models driver-specs.md \u00A78 settings: EndpointUrl (default opc.tcp://localhost:4840 IANA-assigned port), SecurityPolicy/SecurityMode/AuthType enums, Username/Password, SessionTimeout=120s + KeepAliveInterval=5s + ReconnectPeriod=5s (defaults from spec), AutoAcceptCertificates=false (production default; dev turns on for self-signed servers), ApplicationUri + SessionName knobs for certificate SAN matching and remote-server session-list identification. OpcUaClientDriver : IDriver: InitializeAsync builds the ApplicationConfiguration, resolves + creates cert if missing via app.CheckApplicationInstanceCertificatesAsync, selects endpoint via CoreClientUtils.SelectEndpointAsync, builds UserIdentity (Anonymous or Username with UTF-8-encoded password bytes -- the legacy string-password ctor went away; Certificate auth deferred), creates session via DefaultSessionFactory.CreateAsync. Health transitions Unknown -> Initializing -> Healthy on success or -> Faulted on failure with best-effort Session.CloseAsync cleanup. ShutdownAsync (async now, not Task.CompletedTask) closes the session + disposes. Internal Session + Gate expose to the test project via InternalsVisibleTo so PRs 67-69 can stack read/write/discovery/subscribe on the same serialization. Scaffold tests (OpcUaClientDriverScaffoldTests, 5 facts): Default_options_target_standard_opcua_port_and_anonymous_auth (4840 + None mode + Anonymous + AutoAccept=false production default), Default_timeouts_match_driver_specs_section_8 (120s/5s/5s), Driver_reports_type_and_id_before_connect (DriverType=OpcUaClient, DriverInstanceId round-trip, pre-init Unknown health), Initialize_against_unreachable_endpoint_transitions_to_Faulted_and_throws, Reinitialize_against_unreachable_endpoint_re_throws. Uses opc.tcp://127.0.0.1:1 as the 'guaranteed-unreachable' target -- RFC 5737 reserved IPs get black-holed and time out only after the SDK's internal retry/backoff fully elapses (~60s), while port 1 on loopback refuses immediately with TCP RST which keeps the test suite snappy (5 tests / 8s). 5/5 pass. dotnet build clean. Scope boundary: ITagDiscovery / IReadable / IWritable / ISubscribable / IHostConnectivityProbe deliberately NOT in this PR -- they need browse + namespace remapping + reference-counted MonitoredItem forwarding + keep-alive probing and land in PRs 67-69.
2026-04-19 01:07:57 -04:00