Files
lmxopcua/tests
Joseph Doherty 8653960ea3 fix(galaxy): #865 review round 4 - replay fails on a dead stream, backoff-aware wait
- ReplayAsync fails when its restarted pump's stream has already ended, so
  the supervisor backs off and stays Degraded instead of going Healthy over
  a dead stream (whose next advise re-report restarted at attempt 1 with no
  backoff - a tight reconnect loop).
- ReconnectSupervisor.AttemptInProgress (reopen through replay); advises
  wait for a stale pump's replacement only while an attempt is running, not
  for a whole backoff (the state still reads Reopening/Replaying there).
- ReconnectSupervisor: _disposed is set under the state lock and re-checked
  inside ReportTransportFailure, so a late report cannot start a recovery
  loop that StopAsync already missed.
- EventPump.HasEnded is a flag set before StreamRequested is released, and
  a stream that ends/faults on its first MoveNext is marked ended first.
- SubscriptionRegistry fast path: a miss now falls through to the locked
  path (lookup + session + window check atomically) instead of a lock-free
  re-lookup.
- Tests: replay over an immediately-ending stream fails; AttemptInProgress
  across attempt/backoff; ReportTransportFailure after stop; the
  reopen-window test uses a generous wait bound.

Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
2026-11-11 13:07:26 -05:00
..