Files
lmxopcua/tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.OpcUaClient.Tests/OpcUaClientStaleSessionRaceTests.cs
T
Joseph Doherty f7d497e532 refactor(#655): delete the dead driver-side history capability
HistoryRead is served server-side by IHistorianDataSource; nothing ever dispatched
to a driver's IHistoryProvider. Removes IHistoryProvider, the OpcUaClient history
passthrough, DriverCapability.HistoryRead (+ resilience tier rows and AdminUI row),
HistoryReadStatusException and its node-manager catches, and the tests that only
covered them. Shared result types and HistoryAggregateNotSupportedException stay
(moved to Historian/HistoryReadContracts.cs). A stored ResilienceConfig still
carrying a HistoryRead key parses (diagnostic only; new test).

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 23:34:02 -04:00

127 lines
6.7 KiB
C#

using Moq;
using Opc.Ua;
using Opc.Ua.Client;
using Shouldly;
using Xunit;
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
namespace ZB.MOM.WW.OtOpcUa.Driver.OpcUaClient.Tests;
/// <summary>
/// Regression coverage for the stale-session concurrency race in the alarm-acknowledge wire
/// path. A background reconnect handler can swap <see cref="OpcUaClientDriver.Session"/>
/// while a caller is parked on <c>_gate.WaitAsync</c>. If a method captures the session
/// reference <i>before</i> the gate and uses it afterwards, it issues the wire call against
/// the closed/stale session. The correct idiom — already used by ReadAsync/WriteAsync — is
/// a fast-fail guard outside the gate plus an authoritative re-read of <c>Session</c>
/// <i>inside</i> the gate. This test proves the acknowledge path follows it.
/// </summary>
/// <remarks>
/// The swap is staged so the race is exercised, not raced against:
/// <list type="number">
/// <item>The test acquires <c>_gate</c> first, so the method-under-test physically
/// cannot enter the critical section (read Session-in-gate / issue the wire call) until
/// the test releases the gate. Whatever the implementation does <i>after</i> the gate
/// therefore always sees the post-swap session.</item>
/// <item>The only thing that must be ordered is the <b>buggy</b> capture-before-gate:
/// its pre-gate NodeId parse reads the OLD session's <c>MessageContext</c>, which
/// completes a <see cref="TaskCompletionSource"/>. We wait on that signal so the swap
/// lands <i>after</i> the buggy capture has grabbed the OLD session — making the RED
/// outcome deterministic, not timing-dependent.</item>
/// <item>The fixed implementation reads no session member before the gate, so the
/// signal never fires; a bounded fallback then swaps+releases. That is correct for the
/// fixed path because its session read happens only after we release the gate, so the
/// swap is already visible regardless of ordering.</item>
/// </list>
/// A correct implementation re-reads <c>Session</c> inside the gate and lands the wire call
/// on the NEW session; the buggy capture-before-gate code lands it on the OLD one.
/// </remarks>
[Trait("Category", "Unit")]
public sealed class OpcUaClientStaleSessionRaceTests
{
private static Mock<ISession> NewSessionMock(TaskCompletionSource? prologueReached = null)
{
var mock = new Mock<ISession>(MockBehavior.Loose);
// NodeId parsing inside the driver resolves the reference against the session's
// MessageContext. This getter is read in the driver's synchronous prologue (before the
// gate), so signalling here proves the pre-gate capture path has run.
mock.SetupGet(s => s.MessageContext)
.Returns(new ServiceMessageContext(ZB.MOM.WW.OtOpcUa.Driver.OpcUaClient.SdkTelemetry.Context))
.Callback(() => prologueReached?.TrySetResult());
mock.SetupGet(s => s.NamespaceUris).Returns(new NamespaceTable());
// Acknowledge issues its wire call via CallAsync; stub it so AcknowledgeAsync can run to
// completion against whichever session it ends up binding to.
mock.Setup(s => s.CallAsync(
It.IsAny<RequestHeader>(),
It.IsAny<CallMethodRequestCollection>(),
It.IsAny<CancellationToken>()))
.ReturnsAsync(new CallResponse
{
ResponseHeader = new ResponseHeader(),
Results = new CallMethodResultCollection(),
DiagnosticInfos = new DiagnosticInfoCollection(),
});
return mock;
}
private static void VerifyAckWireHitNewSessionNotOld(Mock<ISession> newSession, Mock<ISession> oldSession)
{
newSession.Verify(s => s.CallAsync(
It.IsAny<RequestHeader>(), It.IsAny<CallMethodRequestCollection>(), It.IsAny<CancellationToken>()),
Times.Once);
oldSession.Verify(s => s.CallAsync(
It.IsAny<RequestHeader>(), It.IsAny<CallMethodRequestCollection>(), It.IsAny<CancellationToken>()),
Times.Never);
}
/// <summary>
/// AcknowledgeAsync issues its Acknowledge method <c>CallAsync</c> against the session
/// current after the gate — and parses the namespace-relative ConditionId against that
/// same session — rather than a reference captured before WaitAsync. This is the third
/// gate-protected wire site; the two subscribe paths (<c>SubscribeAsync</c>,
/// <c>SubscribeAlarmsAsync</c>) received the identical fix but are not covered here
/// because asserting them requires a live <c>Subscription</c> object (the SDK's
/// <c>AddSubscription</c>/<c>CreateAsync</c> can't be exercised through this mock seam);
/// their correctness is reviewable by inspection against this same idiom.
/// </summary>
[Fact]
public async Task AcknowledgeAsync_uses_session_swapped_in_across_the_gate_not_the_captured_one()
{
var ct = TestContext.Current.CancellationToken;
using var drv = new OpcUaClientDriver(new OpcUaClientDriverOptions(), "opcua-stale-ack");
var prologueReached = new TaskCompletionSource(TaskCreationOptions.RunContinuationsAsynchronously);
var oldSession = NewSessionMock(prologueReached);
var newSession = NewSessionMock();
drv.SetSessionForTest(oldSession.Object);
await drv.Gate.WaitAsync(ct);
var call = drv.AcknowledgeAsync(
[new AlarmAcknowledgeRequest("ns=2;s=Pump17", "ns=2;s=Pump17", "operator ack")], ct);
await WaitForPreGateCaptureOrFallbackAsync(prologueReached.Task, ct);
drv.SetSessionForTest(newSession.Object);
drv.Gate.Release();
await call;
VerifyAckWireHitNewSessionNotOld(newSession, oldSession);
}
/// <summary>
/// Awaits the buggy path's pre-gate-capture signal, or a bounded fallback when it never
/// fires (the fixed path performs no pre-gate session member read). The buggy-path signal
/// fires from a synchronous <c>MessageContext</c> read that runs before any await, so it
/// always wins the race well inside the fallback — keeping the RED outcome deterministic.
/// The fallback only matters for the GREEN (fixed) path where swap ordering is irrelevant
/// (the fixed read happens only after the gate is released), so a short bound keeps the
/// suite fast without weakening the guarantee.
/// </summary>
private static async Task WaitForPreGateCaptureOrFallbackAsync(Task signal, CancellationToken ct)
{
var fallback = Task.Delay(TimeSpan.FromMilliseconds(250), ct);
await Task.WhenAny(signal, fallback);
}
}