namespace ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.PlcFamilies;
/// <summary>
/// Per-family libplctag defaults for PCCC PLCs. SLC 500 / MicroLogix / PLC-5 / LogixPccc
/// (Logix controller accessed via the PLC-5 compatibility layer — rare but real).
/// </summary>
public sealed record AbLegacyPlcFamilyProfile(
string LibplctagPlcAttribute,
string DefaultCipPath,
int MaxTagBytes,
bool SupportsStringFile,
bool SupportsLongFile,
bool OctalIoAddressing,
bool SupportsFunctionFiles)
{
public static AbLegacyPlcFamilyProfile ForFamily(AbLegacyPlcFamily family) => family switch
{
AbLegacyPlcFamily.Slc500 => Slc500,
AbLegacyPlcFamily.MicroLogix => MicroLogix,
AbLegacyPlcFamily.Plc5 => Plc5,
AbLegacyPlcFamily.LogixPccc => LogixPccc,
_ => Slc500,
};
public static readonly AbLegacyPlcFamilyProfile Slc500 = new(
LibplctagPlcAttribute: "slc500",
DefaultCipPath: "1,0",
MaxTagBytes: 240, // SLC 5/05 PCCC max packet data
SupportsStringFile: true, // ST file available SLC 5/04+
SupportsLongFile: true, // L file available SLC 5/05+
OctalIoAddressing: false, // SLC500 I:/O: indices are decimal in RSLogix 500
SupportsFunctionFiles: false); // SLC500 has no function files
public static readonly AbLegacyPlcFamilyProfile MicroLogix = new(
LibplctagPlcAttribute: "micrologix",
DefaultCipPath: "", // MicroLogix 1100/1400 use direct EIP, no backplane path
MaxTagBytes: 232,
SupportsStringFile: true,
SupportsLongFile: false, // ML 1100/1200/1400 don't ship L files
OctalIoAddressing: false, // MicroLogix follows SLC-style decimal I/O addressing
SupportsFunctionFiles: true); // ML 1100/1400 expose RTC/HSC/DLS/MMI/PTO/PWM/STI/EII/IOS/BHI
public static readonly AbLegacyPlcFamilyProfile Plc5 = new(
LibplctagPlcAttribute: "plc5",
DefaultCipPath: "1,0",
MaxTagBytes: 240, // DF1 full-duplex packet limit at 264 bytes, PCCC-over-EIP caps lower
SupportsStringFile: true,
SupportsLongFile: false, // PLC-5 predates L files
OctalIoAddressing: true, // RSLogix 5 displays I:/O: word + bit indices as octal
SupportsFunctionFiles: false);
/// <summary>
/// Logix ControlLogix / CompactLogix accessed through the legacy PCCC compatibility layer.
/// Rare but real — some legacy HMI integrations address Logix controllers as if they were
/// PLC-5 via the PCCC-passthrough mechanism.
/// </summary>
public static readonly AbLegacyPlcFamilyProfile LogixPccc = new(
LibplctagPlcAttribute: "logixpccc",
DefaultCipPath: "1,0",
MaxTagBytes: 240,
SupportsStringFile: true,
SupportsLongFile: true,
OctalIoAddressing: false, // Logix natively uses decimal arrays even via the PCCC bridge
SupportsFunctionFiles: false);
}
/// <summary>Which PCCC PLC family the device is.</summary>
public enum AbLegacyPlcFamily
{
Slc500,
MicroLogix,
Plc5,
LogixPccc,
}