Joseph Doherty 501d8f494b Task #136 — Modicon address-string parser (5/6-digit) + shared addressing assembly
Foundation for the Modbus addressing-grammar work tracked in #137-#145. Adds
ModbusModiconAddress.Parse / TryParse that turns classic Modicon strings
(40001 / 400001 / 30001 / 00001 / 10001) into (Region, ushort PduOffset).

Also extracts ModbusRegion to a new Driver.Modbus.Addressing assembly so the
Admin UI (#145) can reference the addressing surface without taking a dep on
the wire driver. The new assembly intentionally extends the same
ZB.MOM.WW.OtOpcUa.Driver.Modbus namespace as the driver — callers see the
type as if it lived in one place; only the project layout changes. No
existing call site needed editing (zero-churn move).

Behaviour:
- Single leading digit selects region (0=Coils, 1=DiscreteInputs,
  3=InputRegisters, 4=HoldingRegisters).
- 5-digit form: trailing 4 digits are 1-based register, supports 1..9999.
- 6-digit form: trailing 5 digits are 1-based register, supports 1..65536
  (full PDU address space).
- Strict 5-or-6 length check; whitespace trimmed; clear FormatException
  diagnostics for every malformed shape (wrong length, non-digit body,
  illegal leading digit, register zero, register overflow).

29/29 new unit tests pass. Full Driver.Modbus suite (182 tests) and the
solution-wide build still green after the ModbusRegion move.
2026-04-24 23:34:18 -04:00

20 lines
1.0 KiB
XML

<Project Sdk="Microsoft.NET.Sdk">
<PropertyGroup>
<TargetFramework>net10.0</TargetFramework>
<Nullable>enable</Nullable>
<ImplicitUsings>enable</ImplicitUsings>
<LangVersion>latest</LangVersion>
<TreatWarningsAsErrors>true</TreatWarningsAsErrors>
<GenerateDocumentationFile>true</GenerateDocumentationFile>
<NoWarn>$(NoWarn);CS1591</NoWarn>
<RootNamespace>ZB.MOM.WW.OtOpcUa.Driver.Modbus</RootNamespace>
<Description>Pure Modbus address-grammar parsing — shared by Driver.Modbus, Driver.Modbus.Cli, and Admin so the wire driver and the configuration UI agree on a single grammar definition. Namespace is intentionally identical to Driver.Modbus's so callers see addressing types as if they lived in one assembly; this assembly stays dependency-free so Admin can reference it without taking a transport-layer dep.</Description>
</PropertyGroup>
<ItemGroup>
<InternalsVisibleTo Include="ZB.MOM.WW.OtOpcUa.Driver.Modbus.Addressing.Tests"/>
</ItemGroup>
</Project>