Joseph Doherty
8248b126ce
Phase 3 PR 46 -- DL205 BCD decoder (binary-coded-decimal numeric encoding). Adds ModbusDataType.Bcd16 and Bcd32 to the driver. Bcd16 is 1 register wide, Bcd32 is 2 registers wide; Bcd32 respects ModbusByteOrder (BigEndian/WordSwap) the same way Int32 does so the CDAB-style families (including DL205/DL260 themselves) can be configured. DecodeRegister uses the new internal DecodeBcd helper: walks each nibble from MSB to LSB, multiplies the running result by 10, adds the nibble as a decimal digit. Explicitly rejects nibbles > 9 with InvalidDataException -- hardware sometimes produces garbage during write-in-progress transitions and silently returning wrong numeric values would quietly corrupt the caller's data. EncodeRegister's new EncodeBcd inverts the operation (mod/div by 10 nibble-by-nibble) with an up-front overflow check against 10^nibbles-1. Why this matters for DL205/DL260: AutomationDirect DirectLOGIC uses BCD as the default numeric encoding for timers, counters, and operator-display numerics (not binary). A plain Int16 read of register 0x1234 returns 4660; the BCD path returns 1234. The two differ enough that silently defaulting to Int16 would give wildly wrong HMI values -- the caller must opt in to Bcd16/Bcd32 per tag. Unit tests: DecodeBcd (theory: 0,1,9,10,1234,9999), DecodeBcd_rejects_nibbles_above_nine, EncodeBcd (theory), Bcd16_decodes_DL205_register_1234_as_decimal_1234 (control: same bytes as Int16 decode to 4660), Bcd16_encode_round_trips_with_decode, Bcd16_encode_rejects_out_of_range_values, Bcd32_decodes_8_digits_big_endian, Bcd32_word_swap_handles_CDAB_layout, Bcd32_encode_round_trips_with_decode, Bcd_RegisterCount_matches_underlying_width. 66/66 Modbus.Tests pass. Integration test: DL205BcdQuirkTests.DL205_BCD16_decodes_HR1072_as_decimal_1234 against dl205.json pymodbus profile (HR[1072]=0x1234). Asserts Bcd16 decode=1234 AND Int16 decode=0x1234 on the same wire bytes to prove the paths are distinct. 3/3 DL205 integration tests pass with MODBUS_SIM_PROFILE=dl205.
2026-04-18 21:46:25 -04:00
..
DL205BcdQuirkTests.cs
Phase 3 PR 46 -- DL205 BCD decoder (binary-coded-decimal numeric encoding). Adds ModbusDataType.Bcd16 and Bcd32 to the driver. Bcd16 is 1 register wide, Bcd32 is 2 registers wide; Bcd32 respects ModbusByteOrder (BigEndian/WordSwap) the same way Int32 does so the CDAB-style families (including DL205/DL260 themselves) can be configured. DecodeRegister uses the new internal DecodeBcd helper: walks each nibble from MSB to LSB, multiplies the running result by 10, adds the nibble as a decimal digit. Explicitly rejects nibbles > 9 with InvalidDataException -- hardware sometimes produces garbage during write-in-progress transitions and silently returning wrong numeric values would quietly corrupt the caller's data. EncodeRegister's new EncodeBcd inverts the operation (mod/div by 10 nibble-by-nibble) with an up-front overflow check against 10^nibbles-1. Why this matters for DL205/DL260: AutomationDirect DirectLOGIC uses BCD as the default numeric encoding for timers, counters, and operator-display numerics (not binary). A plain Int16 read of register 0x1234 returns 4660; the BCD path returns 1234. The two differ enough that silently defaulting to Int16 would give wildly wrong HMI values -- the caller must opt in to Bcd16/Bcd32 per tag. Unit tests: DecodeBcd (theory: 0,1,9,10,1234,9999), DecodeBcd_rejects_nibbles_above_nine, EncodeBcd (theory), Bcd16_decodes_DL205_register_1234_as_decimal_1234 (control: same bytes as Int16 decode to 4660), Bcd16_encode_round_trips_with_decode, Bcd16_encode_rejects_out_of_range_values, Bcd32_decodes_8_digits_big_endian, Bcd32_word_swap_handles_CDAB_layout, Bcd32_encode_round_trips_with_decode, Bcd_RegisterCount_matches_underlying_width. 66/66 Modbus.Tests pass. Integration test: DL205BcdQuirkTests.DL205_BCD16_decodes_HR1072_as_decimal_1234 against dl205.json pymodbus profile (HR[1072]=0x1234). Asserts Bcd16 decode=1234 AND Int16 decode=0x1234 on the same wire bytes to prove the paths are distinct. 3/3 DL205 integration tests pass with MODBUS_SIM_PROFILE=dl205.
2026-04-18 21:46:25 -04:00
DL205Profile.cs
Phase 3 PR 43 — followup commit: validate pymodbus simulator end-to-end + fix three real bugs surfaced by running it. winget-installed Python 3.12.10 + pip-installed pymodbus[simulator]==3.13.0 on the dev box; both profiles boot cleanly, the integration-suite smoke test passes against either profile.
2026-04-18 21:14:02 -04:00
DL205SmokeTests.cs
Phase 3 PR 43 — followup commit: validate pymodbus simulator end-to-end + fix three real bugs surfaced by running it. winget-installed Python 3.12.10 + pip-installed pymodbus[simulator]==3.13.0 on the dev box; both profiles boot cleanly, the integration-suite smoke test passes against either profile.
2026-04-18 21:14:02 -04:00
DL205StringQuirkTests.cs
Phase 3 PR 45 -- DL205 string byte-order quirk (low-byte-first ASCII packing). Adds ModbusStringByteOrder enum {HighByteFirst, LowByteFirst} + StringByteOrder field on ModbusTagDefinition (default HighByteFirst, the standard Modbus convention). DecodeRegister + EncodeRegister String branches now respect per-tag byte order. Under LowByteFirst each register packs the first char in the low byte instead of the high byte -- the AutomationDirect DirectLOGIC DL205/DL260/DL350 family's headline string quirk. Without the flag the driver decodes 'eHllo' garbage from HR[1040..1042] even though wire bytes are identical. Unit tests: String_LowByteFirst_decodes_DL205_packed_Hello (5 chars across 3 regs with nul pad), String_LowByteFirst_decode_truncates_at_first_nul, String_LowByteFirst_encode_round_trips_with_decode (asserts exact DL205-documented byte sequence {0x65,0x48,0x6C,0x6C,0x00,0x6F} + symmetric encode->decode), String_HighByteFirst_and_LowByteFirst_differ_on_same_wire (control: same wire, different flag => different decode). 56/56 Modbus.Tests pass. Integration test: DL205StringQuirkTests.DL205_string_low_byte_first_decodes_Hello_from_HR1040 against the dl205.json pymodbus profile; reads HR[1040..1042] with both flags on the same tag map and asserts LowByteFirst='Hello' + HighByteFirst!='Hello'. Gated on MODBUS_SIM_PROFILE=dl205 since the standard profile doesn't seed HR[1040..1042]. Verified 2/2 integration tests pass against running pymodbus dl205 simulator. Baseline for PR 46 (BCD decoder), PR 47 (V-memory octal helper), PR 48 (CDAB float order), PR 49 (FC03/FC16 per-device caps) -- each lands its own DL205_<behavior> test class in tests/.../DL205/.
2026-04-18 21:43:32 -04:00