S7 integration — AbCip/Modbus already have real-simulator integration suites; S7 had zero wire-level coverage despite being a Tier-A driver (all unit tests mocked IS7Client). Picked python-snap7's `snap7.server.Server` over raw Snap7 C library because `pip install` beats per-OS binary-pin maintenance, the package ships a Python __main__ shim that mirrors our existing pymodbus serve.ps1 + *.json pattern structurally, and the python-snap7 project is actively maintained. New project `tests/ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests/` with four moving parts: (a) `Snap7ServerFixture` — collection-scoped TCP probe on `localhost:1102` that sets `SkipReason` when the simulator's not running, matching the `ModbusSimulatorFixture` shape one directory over (same S7_SIM_ENDPOINT env var override convention for pointing at a real S7 CPU on port 102); (b) `PythonSnap7/` — `serve.ps1` wrapper + `server.py` shim + `s7_1500.json` seed profile + `README.md` documenting install / run / known limitations; (c) `S7_1500/S7_1500Profile.cs` — driver-side `S7DriverOptions` whose tag addresses map 1:1 to the JSON profile's seed offsets (DB1.DBW0 u16, DB1.DBW10 i16, DB1.DBD20 i32, DB1.DBD30 f32, DB1.DBX50.3 bool, DB1.DBW100 scratch); (d) `S7_1500SmokeTests` — three tests proving typed reads + write-then-read round-trip work through real S7netplus + real ISO-on-TCP + real snap7 server. Picked port 1102 default instead of S7-standard 102 because 102 is privileged on Linux + triggers Windows Firewall prompt; S7netplus 0.20 has a 5-arg `Plc(CpuType, host, port, rack, slot)` ctor that lets the driver honour `S7DriverOptions.Port`, but the existing driver code called the 4-arg overload + silently hardcoded 102. One-line driver fix (S7Driver.cs:87) threads `_options.Port` through — the S7 unit suite (58/58) still passes unchanged because every unit test uses a fake IS7Client that never sees the real ctor. Server seed-type matrix in `server.py` covers u8 / i8 / u16 / i16 / u32 / i32 / f32 / bool-with-bit / ascii (S7 STRING with max_len header). register_area takes the SrvArea enum value, not the string name — a 15-minute debug after the first test run caught that; documented inline. Per-driver test-fixture coverage docs — eight new files in `docs/drivers/` laying out what each driver's harness actually benchmarks vs. what's trusted from field deployments. Pattern mirrors the AbServer-Test-Fixture.md doc that shipped earlier in this arc: TL;DR → What the fixture is → What it actually covers → What it does NOT cover → When-to-trust table → Follow-up candidates → Key files. Ugly truth the survey made visible: Galaxy + Modbus + (now) S7 + AB CIP have real wire-level coverage; AB Legacy / TwinCAT / FOCAS / OpcUaClient are still contract-only because their libraries ship no fake + no open-source simulator exists (AB Legacy PCCC), no public simulator exists (FOCAS), the vendor SDK has no in-process fake (TwinCAT/ADS.NET), or the test wiring just hasn't happened yet (OpcUaClient could trivially loopback against this repo's own server — flagged as #215). Each doc names the specific follow-up route: Snap7 server for S7 (done), TwinCAT 3 developer-runtime auto-restart for TwinCAT, Tier-C out-of-process Host for FOCAS, lab rigs for AB Legacy + hardware-gated bits of the others. `docs/drivers/README.md` gains a coverage-map section linking all eight. Tracking tasks #215-#222 filed for each PR-able follow-up. Build clean (driver + integration project + docs); S7.Tests 58/58 (unchanged); S7.IntegrationTests 3/3 (new, verified end-to-end against a live python-snap7 server: `driver_reads_seeded_u16_through_real_S7comm`, `driver_reads_seeded_typed_batch`, `driver_write_then_read_round_trip_on_scratch_word`). Next fixture follow-up is #215 (OpcUaClient loopback against own server) — highest ROI of the remaining set, zero external deps. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
python-snap7 server profiles
JSON-driven seed profiles for snap7.server.Server from
python-snap7 (MIT). Shape
mirrors the pymodbus profiles under
tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/Pymodbus/ — a
PowerShell launcher + per-family JSON + a Python shim that the launcher
exec's.
| File | What it seeds | Test category |
|---|---|---|
s7_1500.json |
DB1 (1024 bytes) with smoke values at known offsets (i16 @ DBW10, i32 @ DBD20, f32 @ DBD30, bool @ DBX50.3, scratch word @ DBW100, STRING "Hello" @ 200) + MB (256 bytes) with probe marker at MW0. | Trait=Integration, Device=S7_1500 |
Default port 1102 (non-privileged; sidesteps Windows Firewall prompt +
Linux's root-required bind on port 102). The fixture
(Snap7ServerFixture) defaults to localhost:1102. Override via
S7_SIM_ENDPOINT to point at a real S7 CPU on port 102. The S7 driver
threads _options.Port through to S7netplus's 5-arg Plc ctor, so the
non-standard port works end-to-end.
Install
pip install "python-snap7>=2.0"
python-snap7 wraps the upstream snap7 C library; the install pulls
platform-specific binaries automatically. Requires Python ≥ 3.10.
Windows Firewall will prompt on first bind; allow Private network.
Run
Foreground (Ctrl+C to stop):
.\serve.ps1 -Profile s7_1500
Non-default port:
.\serve.ps1 -Profile s7_1500 -Port 102
Or invoke the Python shim directly:
python .\server.py .\s7_1500.json --port 1102
Run the integration tests
In a separate shell with the simulator running:
cd C:\Users\dohertj2\Desktop\lmxopcua
dotnet test tests\ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests
Tests auto-skip with a clear SkipReason when localhost:1102 isn't
reachable within 2 seconds.
What's encoded in s7_1500.json
| Address | Type | Seed | Purpose |
|---|---|---|---|
DB1.DBW0 |
u16 | 4242 |
read-back probe |
DB1.DBW10 |
i16 | -12345 |
smoke i16 read |
DB1.DBD20 |
i32 | 1234567890 |
smoke i32 read |
DB1.DBD30 |
f32 | 3.14159 |
smoke f32 read (big-endian) |
DB1.DBX50.3 |
bool | true |
smoke bool read at bit 3 |
DB1.DBW100 |
u16 | 0 |
scratch for write-then-read |
DB1.STRING[200] |
S7 STRING | "Hello" (max 32, cur 5) |
smoke string read |
MW0 |
u16 | 1 |
S7ProbeOptions.ProbeAddress default |
Seed types supported by server.py: u8, i8, u16, i16, u32,
i32, f32, bool (with "bit": 0..7), ascii (S7 STRING type with
configurable max_len).
Known limitations (python-snap7 upstream)
The snap7.server.Server docstring admits:
"Legacy S7 server implementation. Emulates a Siemens S7 PLC for testing and development purposes. [...] pure Python emulator implementation that simulates PLC behaviour for protocol compliance testing rather than full industrial-grade functionality."
What that means in practice — things this fixture does NOT cover:
- S7-1500 Optimized-DB symbolic access — the real S7-1500 with TIA Portal optimization enabled uses symbolic addressing that's wire-incompatible with absolute DB addressing. Our driver targets non-optimized DBs; so does snap7's server. Rig test required to verify against an Optimized CPU.
- PG / OP / S7-Basic session types — S7netplus uses OP session; the simulator accepts whatever session type is requested, unlike real CPUs that allocate session slots differently.
- SCL variant-specific behaviour — e.g. S7-1200 missing certain PDU types, S7-300's older handshake, S7-400 multi-CPU racks with non-zero slot. Simulator collapses all into one generic CPU emulation.
- PUT/GET-disabled-by-default — real S7-1200/1500 CPUs refuse reads
when PUT/GET is off in TIA Portal hardware config; the driver maps that
to
BadDeviceFailure. Simulator has no such toggle + always accepts.
References
- python-snap7 GitHub — source + install
- snap7.server API —
Serverclass reference docs/drivers/S7-Test-Fixture.md— coverage map + gap inventorydocs/v2/s7.md— driver-side addressing + family notes