Files
lmxopcua/_p55.json
Joseph Doherty 10c724b5b6 Phase 3 PR 56 -- Siemens S7-1500 pymodbus profile + smoke integration test. Adds tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/Pymodbus/s7_1500.json modelling the SIMATIC S7-1500 + MB_SERVER default deployment documented in docs/v2/s7.md: DB1.DBW0 = 0xABCD fingerprint marker (operators reserve this so clients can verify they're talking to the right DB), scratch HR range 200..209 for write-roundtrip tests mirroring dl205.json + standard.json, Float32 1.5f at HR[100..101] in ABCD word order (high word first -- OPPOSITE of DL260 CDAB), Int32 0x12345678 at HR[300..301] in ABCD. Also seeds a coil at bit-addr 400 (= cell 25 bit 0) and a discrete input at bit-addr 500 (= cell 31 bit 0) so future S7-specific tests for FC01/FC02 have stable markers. shared blocks=true to match the proven dl205.json pattern (pymodbus's bits/uint16 cells coexist cleanly when addresses don't collide). Write list references cells (0, 25, 100-101, 200-209, 300-301), not bit addresses -- pymodbus's write-range entries are cell-indexed, not bit-indexed. Adds tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/S7/ directory with S7_1500Profile.cs (mirrors DL205Profile pattern: SmokeHoldingRegister=200, SmokeHoldingValue=4321, BuildOptions tags + probe-disabled + 2s timeout) and S7_1500SmokeTests.cs (single fact S7_1500_roundtrip_write_then_read_of_holding_register that writes SmokeHoldingValue then reads it back, asserting both write status 0 and read status 0 + value equality). Gates on MODBUS_SIM_PROFILE=s7_1500 so the test skips cleanly against other profiles. csproj updated to copy S7/** to test output as PreserveNewest (pattern matching DL205/**). Pymodbus/serve.ps1 ValidateSet extended from {standard,dl205} to {standard,dl205,s7_1500,mitsubishi} -- mitsubishi.json lands in PR 58 but the validator slot is claimed now so the serve.ps1 diff is one line in this PR and zero lines in future PRs. Verified end-to-end: smoke test 1/1 passes against the running pymodbus s7_1500 profile (localhost:5020 FC06 write of 4321 at HR[200] + FC03 read back). 143/143 Modbus.Tests pass, no regression in driver code because this PR is purely test-asset. Per-quirk S7 integration tests (ABCD word order default, FC23 IllegalFunction, MB_SERVER STATUS 0x8383 behaviour, port-per-connection semantics) land in PR 57+.
2026-04-18 22:57:03 -04:00

2 lines
1.8 KiB
JSON

{"title":"Phase 3 PR 55 -- Mitsubishi MELSEC Modbus TCP quirks research doc","body":"## Summary\n\nAdds `docs/v2/mitsubishi.md` (451 lines) covering MELSEC Q/L/iQ-R/iQ-F/FX3U Modbus TCP behavior. Mirrors `docs/v2/dl205.md` template for per-quirk implementation PRs.\n\n## Key findings for the implementation track\n\n- **Module naming trap** — `QJ71MB91` is SERIAL RTU, not TCP. TCP module is `QJ71MT91`. Surface clearly in driver docs.\n- **No canonical mapping** — per-site 'Modbus Device Assignment Parameter' block (up to 16 entries). Treat mapping as runtime config.\n- **X/Y hex vs octal depends on family** — Q/L/iQ-R use HEX (X20 = decimal 32); FX/iQ-F use OCTAL (X20 = decimal 16). Helper must take a family selector.\n- **Word order CDAB default** across all MELSEC families (opposite of Siemens S7). Driver Mitsubishi profile default: `ByteOrder.WordSwap`.\n- **D-registers binary by default** (opposite of DL205's BCD default). Caller opts in to `Bcd16`/`Bcd32` when ladder uses BCD.\n- **FX5U needs firmware ≥ 1.060** for Modbus TCP server — older is client-only.\n- **FX3U-ENET vs FX3U-ENET-P502 vs FX3U-ENET-ADP** — only the middle one binds port 502; the last has no Modbus at all. Common operator mis-purchase.\n- **QJ71MT91 does NOT support FC22 / FC23** — iQ-R / iQ-F do. Bulk-read optimization must gate on capability.\n- **STOP-mode writes configurable** on Q/L/iQ-R/iQ-F (default accept), always rejected on FX3U-ENET.\n\nThree unconfirmed rumours flagged separately.\n\nNo code, no tests — implementation lands in PRs 58+.\n\n## Test plan\n- [x] Doc renders as markdown\n- [x] 17 citations present\n- [x] Per-model test naming matrix included (`Mitsubishi_QJ71MT91_*`, `Mitsubishi_FX5U_*`, `Mitsubishi_FX3U_ENET_*`, shared `Mitsubishi_Common_*`)","head":"phase-3-pr55-mitsubishi-research-doc","base":"v2"}