SnapshotFormatter.FormatStatus mapped four OPC UA status names to
incorrect numeric codes, mislabelling operator-facing CLI output. The
codes were corrected to their canonical OPC Foundation
Opc.Ua.StatusCodes values:
BadTimeout 0x80060000 -> 0x800A0000
BadNoCommunication 0x80070000 -> 0x80310000
BadWaitingForInitialData 0x80080000 -> 0x80320000
BadNodeIdInvalid 0x80350000 -> 0x80330000
The Cli.Common project does not reference the Opc.Ua package (only
Core.Abstractions / CliFx / Serilog), so the hex literals were
corrected in place with a sync note rather than adding a heavy new
dependency.
SnapshotFormatterTests was updated: the [Theory] expectations now use
the correct spec codes and assert the full rendered form, plus a new
regression [Theory] confirms the pre-fix wrong names no longer apply.
All 24 tests pass.
findings.md: Driver.Cli.Common-001 set to Resolved; open count 6 -> 5.