Files
lmxopcua/src/ZB.MOM.WW.OtOpcUa.Driver.FOCAS/FocasDriverOptions.cs
T
2026-04-25 15:01:37 -04:00

77 lines
3.5 KiB
C#

namespace ZB.MOM.WW.OtOpcUa.Driver.FOCAS;
/// <summary>
/// FOCAS driver configuration. One instance supports N CNC devices. Per plan decision #144
/// each device gets its own <c>(DriverInstanceId, HostAddress)</c> bulkhead key at the
/// Phase 6.1 resilience layer.
/// </summary>
public sealed class FocasDriverOptions
{
public IReadOnlyList<FocasDeviceOptions> Devices { get; init; } = [];
public IReadOnlyList<FocasTagDefinition> Tags { get; init; } = [];
public FocasProbeOptions Probe { get; init; } = new();
public TimeSpan Timeout { get; init; } = TimeSpan.FromSeconds(2);
/// <summary>
/// Fixed-tree behaviour knobs (issue #262, plan PR F1-f). Carries the
/// <c>ApplyFigureScaling</c> toggle that gates the <c>cnc_getfigure</c>
/// decimal-place division applied to position values before publishing.
/// </summary>
public FocasFixedTreeOptions FixedTree { get; init; } = new();
}
/// <summary>
/// Per-driver fixed-tree options. New installs default <see cref="ApplyFigureScaling"/>
/// to <c>true</c> so position values surface in user units (mm / inch). Existing
/// deployments that already published raw scaled integers can flip this to <c>false</c>
/// for migration parity — the operator-facing concern is that switching the flag
/// mid-deployment changes the values clients see, so the migration path is
/// documentation-only (issue #262).
/// </summary>
public sealed record FocasFixedTreeOptions
{
/// <summary>
/// When <c>true</c> (default), position values from <c>cnc_absolute</c> /
/// <c>cnc_machine</c> / <c>cnc_relative</c> / <c>cnc_distance</c> /
/// <c>cnc_actf</c> are divided by <c>10^decimalPlaces</c> per axis using the
/// <c>cnc_getfigure</c> snapshot cached at probe time. When <c>false</c>, the
/// raw integer values are published unchanged — used for migrations from
/// older drivers that didn't apply the scaling.
/// </summary>
public bool ApplyFigureScaling { get; init; } = true;
}
/// <summary>
/// One CNC the driver talks to. <paramref name="Series"/> enables per-series
/// address validation at <see cref="FocasDriver.InitializeAsync"/>; leave as
/// <see cref="FocasCncSeries.Unknown"/> to skip validation (legacy behaviour).
/// <paramref name="OverrideParameters"/> declares the four MTB-specific override
/// <c>cnc_rdparam</c> numbers surfaced under <c>Override/</c>; pass <c>null</c> to
/// suppress the entire <c>Override/</c> subfolder for that device (issue #259).
/// </summary>
public sealed record FocasDeviceOptions(
string HostAddress,
string? DeviceName = null,
FocasCncSeries Series = FocasCncSeries.Unknown,
FocasOverrideParameters? OverrideParameters = null);
/// <summary>
/// One FOCAS-backed OPC UA variable. <paramref name="Address"/> is the canonical FOCAS
/// address string that parses via <see cref="FocasAddress.TryParse"/> —
/// <c>X0.0</c> / <c>R100</c> / <c>PARAM:1815/0</c> / <c>MACRO:500</c>.
/// </summary>
public sealed record FocasTagDefinition(
string Name,
string DeviceHostAddress,
string Address,
FocasDataType DataType,
bool Writable = true,
bool WriteIdempotent = false);
public sealed class FocasProbeOptions
{
public bool Enabled { get; init; } = true;
public TimeSpan Interval { get; init; } = TimeSpan.FromSeconds(5);
public TimeSpan Timeout { get; init; } = TimeSpan.FromSeconds(2);
}