Files
lmxopcua/src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Addressing/DirectLogicAddress.cs
T
Joseph Doherty 64e3fbe035
v2-ci / build (push) Failing after 1m43s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests) (push) Has been skipped
docs: backfill XML documentation across 756 files
Adds <summary>, <param>, <typeparam>, and <inheritdoc/> tags to public
members surfaced by commentchecker — resolves 5,847 of 5,869 issues
(99.6%) across three /fixdocs passes.
2026-05-28 08:10:17 -04:00

222 lines
11 KiB
C#

namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus;
/// <summary>
/// AutomationDirect DirectLOGIC address-translation helpers. DL205 / DL260 / DL350 CPUs
/// address V-memory in OCTAL while the Modbus wire uses DECIMAL PDU addresses — operators
/// see "V2000" in the PLC ladder-logic editor but the Modbus client must write PDU 0x0400.
/// The formulas differ between user V-memory (simple octal-to-decimal) and system V-memory
/// (fixed bank mappings), so the two cases are separate methods rather than one overloaded
/// "ToPdu" call.
/// </summary>
/// <remarks>
/// See <c>docs/v2/dl205.md</c> §V-memory for the full CPU-family matrix + rationale.
/// References: D2-USER-M appendix (DL205/D2-260), H2-ECOM-M §6.5 (absolute vs relative
/// addressing), AutomationDirect forum guidance on V40400 system-base.
/// </remarks>
public static class DirectLogicAddress
{
/// <summary>
/// Convert a DirectLOGIC user V-memory address (octal) to a 0-based Modbus PDU address.
/// Accepts bare octal (<c>"2000"</c>) or <c>V</c>-prefixed (<c>"V2000"</c>). Range
/// depends on CPU model — DL205 D2-260 user memory is V1400-V7377 + V10000-V17777
/// octal, DL260 extends to V77777 octal.
/// </summary>
/// <param name="vAddress">The V-memory address (octal, with optional V prefix).</param>
/// <remarks>
/// This handles ONLY user V-memory (octal address below the system base, V40400). For a
/// V-address that may fall in either bank, call <see cref="VMemoryToPdu"/>, which routes
/// system-bank addresses through <see cref="SystemVMemoryToPdu"/> instead.
/// </remarks>
/// <exception cref="ArgumentException">Input is null / empty / contains non-octal digits (8,9).</exception>
/// <exception cref="OverflowException">Parsed value exceeds ushort.MaxValue (0xFFFF).</exception>
public static ushort UserVMemoryToPdu(string vAddress)
=> (ushort)DecodeOctalVAddress(vAddress); // DecodeOctalVAddress guards the 0xFFFF ceiling
/// <summary>
/// Decode the octal digits of a V-address (with optional <c>V</c> prefix) to a uint.
/// Used both as the user-memory PDU value and as the octal magnitude that decides which
/// bank a V-address belongs to.
/// </summary>
private static uint DecodeOctalVAddress(string vAddress)
{
if (string.IsNullOrWhiteSpace(vAddress))
throw new ArgumentException("V-memory address must not be empty", nameof(vAddress));
var s = vAddress.Trim();
if (s[0] == 'V' || s[0] == 'v') s = s.Substring(1);
if (s.Length == 0)
throw new ArgumentException($"V-memory address '{vAddress}' has no digits", nameof(vAddress));
// Octal conversion. Reject 8/9 digits up-front — int.Parse in the obvious base would
// accept them silently because .NET has no built-in base-8 parser.
uint result = 0;
foreach (var ch in s)
{
if (ch < '0' || ch > '7')
throw new ArgumentException(
$"V-memory address '{vAddress}' contains non-octal digit '{ch}' — DirectLOGIC V-addresses are octal (0-7)",
nameof(vAddress));
result = result * 8 + (uint)(ch - '0');
if (result > ushort.MaxValue)
throw new OverflowException(
$"V-memory address '{vAddress}' exceeds the 16-bit Modbus PDU address range");
}
return result;
}
/// <summary>
/// DirectLOGIC system V-memory starts at octal V40400 on DL260 / H2-ECOM100 in factory
/// "absolute" addressing mode. Unlike user V-memory, the mapping is NOT a simple
/// octal-to-decimal conversion — the CPU relocates the system bank to Modbus PDU 0x2100
/// (decimal 8448). This helper returns the CPU-family base plus a user-supplied offset
/// within the system bank.
/// </summary>
public const ushort SystemVMemoryBasePdu = 0x2100;
/// <summary>
/// Octal magnitude of the first system V-memory register (V40400). A V-address whose
/// octal-decoded value is at or above this belongs to the system bank and must NOT be
/// mapped with the plain octal-to-decimal user formula — see <see cref="VMemoryToPdu"/>.
/// </summary>
/// <remarks>Octal 40400 == decimal 16640 (0x4100).</remarks>
public const ushort SystemVMemoryOctalBase = 0x4100; // octal 40400 decoded
/// <param name="offsetWithinSystemBank">
/// 0-based register offset within the system bank. Pass 0 for V40400 itself; pass 1 for
/// V40401 (octal), and so on. NOT an octal-decoded value — the system bank lives at
/// consecutive PDU addresses, so the offset is plain decimal.
/// </param>
public static ushort SystemVMemoryToPdu(ushort offsetWithinSystemBank)
{
var pdu = SystemVMemoryBasePdu + offsetWithinSystemBank;
if (pdu > ushort.MaxValue)
throw new OverflowException(
$"System V-memory offset {offsetWithinSystemBank} maps past 0xFFFF");
return (ushort)pdu;
}
/// <summary>
/// Convert any DirectLOGIC V-memory address (octal, optional <c>V</c> prefix) to a 0-based
/// Modbus PDU address, routing user-bank and system-bank addresses through the correct
/// formula. User V-memory (octal &lt; V40400) is a plain octal-to-decimal decode; system
/// V-memory (octal &gt;= V40400) is relocated to the fixed system base at PDU 0x2100.
/// This is the address the parser must use — the system bank is NOT a simple octal decode.
/// </summary>
/// <param name="vAddress">The V-memory address (octal, with optional V prefix).</param>
/// <remarks>
/// The system-bank consecutive offset is the octal-decoded distance from V40400, not an
/// octal-decoded value itself: V40400 → PDU 0x2100, V40401 → 0x2101, and so on.
/// See <c>docs/v2/dl205.md</c> §V-Memory Addressing.
/// </remarks>
/// <exception cref="ArgumentException">Input is null / empty / contains non-octal digits.</exception>
/// <exception cref="OverflowException">The result exceeds the 16-bit Modbus PDU range.</exception>
public static ushort VMemoryToPdu(string vAddress)
{
var octalValue = DecodeOctalVAddress(vAddress);
if (octalValue < SystemVMemoryOctalBase)
return (ushort)octalValue;
// System bank: the registers are contiguous from V40400, so the offset within the bank
// is the plain decimal distance from the octal base, not another octal decode.
var offsetWithinBank = octalValue - SystemVMemoryOctalBase;
if (offsetWithinBank > ushort.MaxValue)
throw new OverflowException(
$"V-memory address '{vAddress}' is outside the addressable system bank");
return SystemVMemoryToPdu((ushort)offsetWithinBank);
}
// Bit-memory bases per DL260 user manual §I/O-configuration.
// Numbers after X / Y / C / SP are OCTAL in DirectLOGIC notation. The Modbus base is
// added to the octal-decoded offset; e.g. Y017 = Modbus coil 2048 + octal(17) = 2048 + 15 = 2063.
/// <summary>
/// DL260 Y-output coil base. Y0 octal → Modbus coil address 2048 (0-based).
/// </summary>
public const ushort YOutputBaseCoil = 2048;
/// <summary>
/// DL260 C-relay coil base. C0 octal → Modbus coil address 3072 (0-based).
/// </summary>
public const ushort CRelayBaseCoil = 3072;
/// <summary>
/// DL260 X-input discrete-input base. X0 octal → Modbus discrete input 0.
/// </summary>
public const ushort XInputBaseDiscrete = 0;
/// <summary>
/// DL260 SP special-relay discrete-input base. SP0 octal → Modbus discrete input 1024.
/// Read-only; writing SP relays is rejected with Illegal Data Address.
/// </summary>
public const ushort SpecialBaseDiscrete = 1024;
/// <summary>
/// Translate a DirectLOGIC Y-output address (e.g. <c>"Y0"</c>, <c>"Y17"</c>) to its
/// 0-based Modbus coil address on DL260. The trailing number is OCTAL, matching the
/// ladder-logic editor's notation.
/// </summary>
/// <param name="yAddress">The Y-output address (octal, with optional Y prefix).</param>
public static ushort YOutputToCoil(string yAddress) =>
AddOctalOffset(YOutputBaseCoil, StripPrefix(yAddress, 'Y'));
/// <summary>
/// Translate a DirectLOGIC C-relay address (e.g. <c>"C0"</c>, <c>"C1777"</c>) to its
/// 0-based Modbus coil address.
/// </summary>
/// <param name="cAddress">The C-relay address (octal, with optional C prefix).</param>
public static ushort CRelayToCoil(string cAddress) =>
AddOctalOffset(CRelayBaseCoil, StripPrefix(cAddress, 'C'));
/// <summary>
/// Translate a DirectLOGIC X-input address (e.g. <c>"X0"</c>, <c>"X17"</c>) to its
/// 0-based Modbus discrete-input address. Reading an unpopulated X returns 0, not an
/// exception — the CPU sizes the table to configured I/O, not installed modules.
/// </summary>
/// <param name="xAddress">The X-input address (octal, with optional X prefix).</param>
public static ushort XInputToDiscrete(string xAddress) =>
AddOctalOffset(XInputBaseDiscrete, StripPrefix(xAddress, 'X'));
/// <summary>
/// Translate a DirectLOGIC SP-special-relay address (e.g. <c>"SP0"</c>) to its 0-based
/// Modbus discrete-input address. Accepts <c>"SP"</c> prefix case-insensitively.
/// </summary>
/// <param name="spAddress">The SP special-relay address (octal, with optional SP prefix).</param>
public static ushort SpecialToDiscrete(string spAddress)
{
if (string.IsNullOrWhiteSpace(spAddress))
throw new ArgumentException("SP address must not be empty", nameof(spAddress));
var s = spAddress.Trim();
if (s.Length >= 2 && (s[0] == 'S' || s[0] == 's') && (s[1] == 'P' || s[1] == 'p'))
s = s.Substring(2);
return AddOctalOffset(SpecialBaseDiscrete, s);
}
private static string StripPrefix(string address, char expectedPrefix)
{
if (string.IsNullOrWhiteSpace(address))
throw new ArgumentException("Address must not be empty", nameof(address));
var s = address.Trim();
if (s.Length > 0 && char.ToUpperInvariant(s[0]) == char.ToUpperInvariant(expectedPrefix))
s = s.Substring(1);
return s;
}
private static ushort AddOctalOffset(ushort baseAddr, string octalDigits)
{
if (octalDigits.Length == 0)
throw new ArgumentException("Address has no digits", nameof(octalDigits));
uint offset = 0;
foreach (var ch in octalDigits)
{
if (ch < '0' || ch > '7')
throw new ArgumentException(
$"Address contains non-octal digit '{ch}' — DirectLOGIC I/O addresses are octal (0-7)",
nameof(octalDigits));
offset = offset * 8 + (uint)(ch - '0');
}
var result = baseAddr + offset;
if (result > ushort.MaxValue)
throw new OverflowException($"Address {baseAddr}+{offset} exceeds 0xFFFF");
return (ushort)result;
}
}