Parent: #209. Follow-up to #210 (Modbus). Registers the remaining three non-Galaxy driver factories so a Config DB `DriverType` in {`AbCip`, `S7`, `AbLegacy`} actually boots a live driver instead of being silently skipped by DriverInstanceBootstrapper. Each factory follows the same shape as ModbusDriverFactoryExtensions + the existing Galaxy + FOCAS patterns: - Static `Register(DriverFactoryRegistry)` entry point. - Internal `CreateInstance(driverInstanceId, driverConfigJson)` — deserialises a DTO, strict-parses enum fields (fail-fast with an explicit "expected one of" list), composes the driver's options object, returns a new driver. - DriverType keys: `"AbCip"`, `"S7"`, `"AbLegacy"` (case-insensitive at the registry layer). DTO surfaces cover every option the respective driver's Options class exposes — devices, tags, probe, timeouts, per-driver quirks (AbCip `EnableControllerBrowse` / `EnableAlarmProjection`, S7 Rack/Slot/ CpuType, AbLegacy PlcFamily). Seed SQL (mirrors `seed-modbus-smoke.sql` shape): - `seed-abcip-smoke.sql` — `abcip-smoke` cluster + ControlLogix device + `TestDINT:DInt` tag, pointing at the ab_server compose fixture (`ab://127.0.0.1:44818/1,0`). - `seed-s7-smoke.sql` — `s7-smoke` cluster + S71500 CPU + `DB1.DBW0:Int16` tag at the python-snap7 fixture (`127.0.0.1:1102`, non-priv port). - `seed-ablegacy-smoke.sql` — `ablegacy-smoke` cluster + SLC 500 + `N7:5` tag. Hardware-gated per #222; placeholder gateway to be replaced with real SLC/MicroLogix/PLC-5/RSEmulate before running. Build plumbing: - Each driver project now ProjectReferences `Core` (was `Core.Abstractions`-only). `DriverFactoryRegistry` lives in `Core.Hosting` so the factory extensions can't compile without it. Matches the FOCAS + Galaxy.Proxy reference shape. - `Server.csproj` adds the three new driver ProjectReferences so Program.cs resolves the symbols at compile-time + ships the assemblies at runtime. Full-solution build: 0 errors, 334 pre-existing xUnit1051 warnings only. Live boot verification of all four (Modbus + these three) happens in the exit-gate PR — factories + seeds are pre-conditions and are being shipped first so the exit-gate PR can scope to "does the server publish the expected NodeIds + does the e2e script pass." Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
32 lines
1.2 KiB
XML
32 lines
1.2 KiB
XML
<Project Sdk="Microsoft.NET.Sdk">
|
|
|
|
<PropertyGroup>
|
|
<TargetFramework>net10.0</TargetFramework>
|
|
<Nullable>enable</Nullable>
|
|
<ImplicitUsings>enable</ImplicitUsings>
|
|
<LangVersion>latest</LangVersion>
|
|
<TreatWarningsAsErrors>true</TreatWarningsAsErrors>
|
|
<GenerateDocumentationFile>true</GenerateDocumentationFile>
|
|
<NoWarn>$(NoWarn);CS1591</NoWarn>
|
|
<RootNamespace>ZB.MOM.WW.OtOpcUa.Driver.AbCip</RootNamespace>
|
|
<AssemblyName>ZB.MOM.WW.OtOpcUa.Driver.AbCip</AssemblyName>
|
|
</PropertyGroup>
|
|
|
|
<ItemGroup>
|
|
<ProjectReference Include="..\ZB.MOM.WW.OtOpcUa.Core.Abstractions\ZB.MOM.WW.OtOpcUa.Core.Abstractions.csproj"/>
|
|
<ProjectReference Include="..\ZB.MOM.WW.OtOpcUa.Core\ZB.MOM.WW.OtOpcUa.Core.csproj"/>
|
|
</ItemGroup>
|
|
|
|
<ItemGroup>
|
|
<!-- libplctag managed wrapper (pulls in libplctag.NativeImport transitively).
|
|
Decision #11 — EtherNet/IP + CIP + Logix symbolic against ControlLogix / CompactLogix /
|
|
Micro800 / SLC500 / PLC-5. -->
|
|
<PackageReference Include="libplctag" Version="1.5.2"/>
|
|
</ItemGroup>
|
|
|
|
<ItemGroup>
|
|
<InternalsVisibleTo Include="ZB.MOM.WW.OtOpcUa.Driver.AbCip.Tests"/>
|
|
</ItemGroup>
|
|
|
|
</Project>
|