Files
lmxopcua/src/ZB.MOM.WW.OtOpcUa.Core.Abstractions/IHistoryProvider.cs
Joseph Doherty bf329b05d8 Phase 3 PR 35 — IHistoryProvider gains ReadAtTimeAsync + ReadEventsAsync; GalaxyProxyDriver implements both. Extends Core.Abstractions.IHistoryProvider with two new methods that round out the OPC UA Part 11 HistoryRead surface (HistoryReadAtTime + HistoryReadEvents are the last two modes not covered by the PR 19-era ReadRawAsync + ReadProcessedAsync) and wires GalaxyProxyDriver to call the existing PR-10/PR-11 IPC contracts the Host already implements.
Interface additions use C# default interface implementations that throw NotSupportedException — existing IHistoryProvider implementations keep compiling, only drivers whose backend carries the relevant capability override. This matches the 'capabilities are optional per driver' design already used by IHistoryProvider.ReadProcessedAsync's docs (Modbus / OPC UA Client drivers never had an event historian and the default-throw path lets callers see BadHistoryOperationUnsupported naturally). New HistoricalEvent record models one historian row (EventId, SourceName, EventTimeUtc + ReceivedTimeUtc — process vs historian-persist timestamps, Message, Severity mapped to OPC UA's 1-1000 range); HistoricalEventsResult pairs the event list with a continuation-point token for future batching. Both live in Core.Abstractions so downstream (Proxy, Host, Server) reference a single domain shape — no Shared-contract leak into the driver-facing interface.
GalaxyProxyDriver.ReadAtTimeAsync maps the domain DateTime[] to Unix-ms longs, calls CallAsync on the existing MessageKind.HistoryReadAtTimeRequest, and trusts the Host's one-sample-per-requested-timestamp contract (the Host pads with bad-quality snapshots for timestamps it can't interpolate; re-aligning on the Proxy side would duplicate the Host's interpolation policy logic). ReadEventsAsync does the same for HistoryReadEventsRequest; ToHistoricalEvent translates GalaxyHistoricalEvent (MessagePack-annotated, Unix-ms) to the domain record, explicitly tagging DateTimeKind.Utc on both timestamp fields so downstream serializers (JSON, OPC UA types) don't apply an unexpected local-time offset.
Tests — HistoricalEventMappingTests (3 new Proxy.Tests unit cases): every field maps correctly from wire to domain; null SourceName and null DisplayText preserve through the mapping (system events without a source come out with null so callers can distinguish them from alarm events); both timestamps come out as DateTimeKind.Utc (regression guard against a future refactor using DateTime.FromFileTimeUtc or similar that defaults to Unspecified). Driver.Galaxy.Proxy.Tests Unit suite: 17 pass / 0 fail (14 prior + 3 new). Full solution build clean, 0 errors.
Scope exclusions — DriverNodeManager HistoryRead service-handler wiring (on the OPC UA Server side, where HistoryReadAtTime and HistoryReadEvents service requests land) and the full-loop integration test (OPC UA client → server → IPC → Host → HistorianDataSource → back) are deferred to a focused follow-up PR. The capability surface is the load-bearing change; wiring the service handlers is mechanical in comparison and worth its own PR for reviewability. docs/v2/lmx-followups.md #1 updated with the split.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-18 16:08:27 -04:00

123 lines
5.9 KiB
C#

namespace ZB.MOM.WW.OtOpcUa.Core.Abstractions;
/// <summary>
/// Driver capability for historical-data reads (OPC UA HistoryRead). Optional —
/// only drivers whose backends carry historian data implement this. Currently:
/// Galaxy (Wonderware Historian via the optional plugin), OPC UA Client (forward
/// to upstream server).
/// </summary>
public interface IHistoryProvider
{
/// <summary>
/// Read raw historical samples for a single attribute over a time range.
/// The Core wraps this with continuation-point handling.
/// </summary>
Task<HistoryReadResult> ReadRawAsync(
string fullReference,
DateTime startUtc,
DateTime endUtc,
uint maxValuesPerNode,
CancellationToken cancellationToken);
/// <summary>
/// Read processed (aggregated) samples — interval-bucketed average / min / max / etc.
/// Optional — drivers that only support raw history can throw <see cref="NotSupportedException"/>.
/// </summary>
Task<HistoryReadResult> ReadProcessedAsync(
string fullReference,
DateTime startUtc,
DateTime endUtc,
TimeSpan interval,
HistoryAggregateType aggregate,
CancellationToken cancellationToken);
/// <summary>
/// Read one sample per requested timestamp — OPC UA HistoryReadAtTime service. The
/// driver interpolates (or returns the prior-boundary sample) when no exact match
/// exists. Optional; drivers that can't interpolate throw <see cref="NotSupportedException"/>.
/// </summary>
/// <remarks>
/// Default implementation throws. Drivers opt in by overriding; keeps existing
/// <c>IHistoryProvider</c> implementations compiling without forcing a ReadAtTime path
/// they may not have a backend for.
/// </remarks>
Task<HistoryReadResult> ReadAtTimeAsync(
string fullReference,
IReadOnlyList<DateTime> timestampsUtc,
CancellationToken cancellationToken)
=> throw new NotSupportedException(
$"{GetType().Name} does not implement ReadAtTimeAsync. " +
"Drivers whose backends support at-time reads override this method.");
/// <summary>
/// Read historical alarm/event records — OPC UA HistoryReadEvents service. Distinct
/// from the live event stream — historical rows come from an event historian (Galaxy's
/// Alarm Provider history log, etc.) rather than the driver's active subscription.
/// </summary>
/// <param name="sourceName">
/// Optional filter: null means "all sources", otherwise restrict to events from that
/// source-object name. Drivers may ignore the filter if the backend doesn't support it.
/// </param>
/// <param name="startUtc">Inclusive lower bound on <c>EventTimeUtc</c>.</param>
/// <param name="endUtc">Exclusive upper bound on <c>EventTimeUtc</c>.</param>
/// <param name="maxEvents">Upper cap on returned events — the driver's backend enforces this.</param>
/// <param name="cancellationToken">Request cancellation.</param>
/// <remarks>
/// Default implementation throws. Only drivers with an event historian (Galaxy via the
/// Wonderware Alarm &amp; Events log) override. Modbus / the OPC UA Client driver stay
/// with the default and let callers see <c>BadHistoryOperationUnsupported</c>.
/// </remarks>
Task<HistoricalEventsResult> ReadEventsAsync(
string? sourceName,
DateTime startUtc,
DateTime endUtc,
int maxEvents,
CancellationToken cancellationToken)
=> throw new NotSupportedException(
$"{GetType().Name} does not implement ReadEventsAsync. " +
"Drivers whose backends have an event historian override this method.");
}
/// <summary>Result of a HistoryRead call.</summary>
/// <param name="Samples">Returned samples in chronological order.</param>
/// <param name="ContinuationPoint">Opaque token for the next call when more samples are available; null when complete.</param>
public sealed record HistoryReadResult(
IReadOnlyList<DataValueSnapshot> Samples,
byte[]? ContinuationPoint);
/// <summary>Aggregate function for processed history reads. Mirrors OPC UA Part 13 standard aggregates.</summary>
public enum HistoryAggregateType
{
Average,
Minimum,
Maximum,
Total,
Count,
}
/// <summary>
/// One row returned by <see cref="IHistoryProvider.ReadEventsAsync"/> — a historical
/// alarm/event record, not the OPC UA live-event stream. Fields match the minimum set the
/// Server needs to populate a <c>HistoryEventFieldList</c> for HistoryReadEvents responses.
/// </summary>
/// <param name="EventId">Stable unique id for the event — driver-specific format.</param>
/// <param name="SourceName">Source object that emitted the event. May differ from the <c>sourceName</c> filter the caller passed (fuzzy matches).</param>
/// <param name="EventTimeUtc">Process-side timestamp — when the event actually occurred.</param>
/// <param name="ReceivedTimeUtc">Historian-side timestamp — when the historian persisted the row; may lag <paramref name="EventTimeUtc"/> by the historian's buffer flush cadence.</param>
/// <param name="Message">Human-readable message text.</param>
/// <param name="Severity">OPC UA severity (1-1000). Drivers map their native priority scale onto this range.</param>
public sealed record HistoricalEvent(
string EventId,
string? SourceName,
DateTime EventTimeUtc,
DateTime ReceivedTimeUtc,
string? Message,
ushort Severity);
/// <summary>Result of a <see cref="IHistoryProvider.ReadEventsAsync"/> call.</summary>
/// <param name="Events">Events in chronological order by <c>EventTimeUtc</c>.</param>
/// <param name="ContinuationPoint">Opaque token for the next call when more events are available; null when complete.</param>
public sealed record HistoricalEventsResult(
IReadOnlyList<HistoricalEvent> Events,
byte[]? ContinuationPoint);