7829b937d1
OpcUa:Redundancy:Mode (Unset default = today's server exactly; None; Warm; Hot and unknown values fail start). - T1 options + validator + effective-URI check + boot banner; Warm needs the driver role. - T2 metadata in OnNodeManagerStartedAsync: Warm -> NonTransparentRedundancyType, read-only ServerUriArray [self, peers], RedundancySupport=Warm, boot ServiceLevel 1; None -> RedundancySupport=None and the SDK's orphan i=11314 deleted; Unset untouched. - T3 RedundancyStateChanged.Revision (up-number, incarnation tick, sequence); subscribers drop older revisions under Warm (OpcUaPublishActor, DriverHostActor); unrevisioned never makes a node Active. - T4 WarmRoleAuthority + ComputeWarm bands (Standby 90/50, Active 250/200/100), PromoteWhilePrimaryUnreachable. - T5 IStandbyProjection + DeferredStandbyProjection; OpcUaPublishActor runs promotion/demotion in the spec 4.7 order (Active level last and retried; Standby level first, data degraded regardless). - T6 EquipmentVariableState read projection (BadOutOfService/null); Warm Standby refuses writes BadInvalidState. - T7 D4 mechanism adopted after T0: ordinary-tag marker on MonitoredItemNotification.Message validated by (ClientHandle, DataValue); first-delivery decision keyed by (SubscriptionId, SequenceNumber); the SDK's cached copy is never mutated. - T8 queue current/BadOutOfService to live ordinary-tag items ignoring filters. - T9 alarm stamp/deliver split (suppressed on Standby), Part 9 methods refused on Standby, promotion refresh via ISubscription.ConditionRefresh2Async on every live event item. - T10 deploy-time RedundancyMode cross-check + six instruments. Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
28 lines
1.4 KiB
C#
28 lines
1.4 KiB
C#
using ZB.MOM.WW.OtOpcUa.Commons.OpcUa;
|
|
using ZB.MOM.WW.OtOpcUa.OpcUaServer;
|
|
|
|
namespace ZB.MOM.WW.OtOpcUa.Host.Configuration;
|
|
|
|
/// <summary>
|
|
/// The one Gitea #717 startup rule the options validator cannot see: <c>OpcUa:Redundancy:Mode=Warm</c> needs the
|
|
/// <c>driver</c> role (the validator is registered only on driver nodes, so on any other node it would never run).
|
|
/// </summary>
|
|
public static class OpcUaRedundancyStartupGuard
|
|
{
|
|
/// <summary>Fails host start when a node without the driver role is configured Warm.</summary>
|
|
/// <param name="configuredMode">The raw <c>OpcUa:Redundancy:Mode</c> value.</param>
|
|
/// <param name="hasDriver">Whether this node carries the driver role.</param>
|
|
/// <exception cref="InvalidOperationException">Warm without the driver role.</exception>
|
|
public static void RequireDriverRoleForWarm(string? configuredMode, bool hasDriver)
|
|
{
|
|
if (hasDriver) return;
|
|
var options = new OpcUaRedundancyOptions { Mode = configuredMode ?? string.Empty };
|
|
if (options.TryParseMode(out var mode) && mode == OpcUaRedundancyMode.Warm)
|
|
{
|
|
throw new InvalidOperationException(
|
|
"OpcUa:Redundancy:Mode is Warm on a node without the driver role; Warm redundancy needs the driver role "
|
|
+ "(the OPC UA endpoint is served by driver nodes only). Remove the setting or add the driver role.");
|
|
}
|
|
}
|
|
}
|