Files
lmxopcua/tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.MTConnect.Tests/MTConnectPumpGenerationTests.cs
T

109 lines
4.5 KiB
C#

using Shouldly;
using Xunit;
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
namespace ZB.MOM.WW.OtOpcUa.Driver.MTConnect.Tests;
/// <summary>
/// STAB-20 / #602 — a Subscribe that lands between <c>StopSampleStreamAsync</c> clearing the pump slots
/// and the teardown that retires the client started a pump on the soon-to-be-disposed session. The
/// lifecycle restart then saw "a pump is running" and never started one against the new session, leaving
/// the subscription with no live stream. The pump is now stamped with the session generation and a
/// start request supersedes a pump from an older one.
/// </summary>
public sealed class MTConnectPumpGenerationTests
{
private static readonly TimeSpan Watchdog = TimeSpan.FromSeconds(10);
private static CancellationToken Ct => TestContext.Current.CancellationToken;
/// <summary>The pump a mid-restart Subscribe started on the retired client is replaced by one on the new client.</summary>
[Fact]
public async Task Subscribe_during_a_lifecycle_restart_rebinds_the_pump_to_the_new_client()
{
var clientA = CannedAgentClient.FromFixtures();
var clientB = CannedAgentClient.FromFixtures();
var clients = new Queue<CannedAgentClient>([clientA, clientB]);
var driver = new MTConnectDriver(
new MTConnectDriverOptions
{
AgentUri = "http://fixture-agent:5000",
RequestTimeoutMs = 5000,
Tags = [new MTConnectTagDefinition("dev1_pos", DriverDataType.Float64)],
},
"mt-gen",
_ => clients.Dequeue());
await driver.InitializeAsync("{}", Ct);
Task[] retired = [];
var blockOnce = 0;
var blocking = new ManualResetEventSlim(false);
var entered = new TaskCompletionSource(TaskCreationOptions.RunContinuationsAsynchronously);
driver.OnDataChange += (_, e) =>
{
// Once only: the second subscriber's initial-data callback replays the same 1.5 and must not wedge.
if (e.Snapshot.Value is not 1.5d || Interlocked.Exchange(ref blockOnce, 1) != 0)
{
return;
}
entered.TrySetResult();
blocking.Wait();
};
try
{
await driver.SubscribeAsync(["dev1_pos"], TimeSpan.FromMilliseconds(50), Ct);
_ = clientA.PumpAsync(MTConnectPumpGenerationChunks.Pos(108, 113, "1.5"));
await entered.Task.WaitAsync(Watchdog, Ct);
// The first pump is now wedged in caller code. A re-initialize clears the pump slots and then
// waits (bounded) on it, which is the window the race lives in.
var restart = driver.InitializeAsync("{}", Ct);
var spins = 0;
while (driver.SampleStreamTask is not null)
{
await Task.Delay(10, Ct);
(++spins).ShouldBeLessThan(500, "restart never cleared the pump slot");
}
// A second subscriber arrives mid-restart: it starts a pump on the (still-live) old client.
await driver.SubscribeAsync(["dev1_pos"], TimeSpan.FromMilliseconds(50), Ct);
await clientA.WaitForSampleCallsAsync(2).WaitAsync(Watchdog, Ct);
restart.IsCompleted.ShouldBeFalse();
blocking.Set();
await restart.WaitAsync(Watchdog, Ct);
// The pump retired by the restart is retained so shutdown can join it (it used to be dropped
// un-awaited and could write health after the new session was Healthy).
retired = driver.SupersededPumpTasks;
retired.ShouldNotBeEmpty();
// The restart installed a new client; the standing subscription must be streaming from IT.
await clientB.WaitForSampleCallsAsync(1).WaitAsync(Watchdog, Ct);
clientA.IsDisposed.ShouldBeTrue();
}
finally
{
blocking.Set();
await driver.ShutdownAsync(CancellationToken.None);
}
// Shutdown joined every retired pump and forgot them.
retired.ShouldAllBe(t => t.IsCompleted);
driver.SupersededPumpTasks.ShouldBeEmpty();
}
}
internal static class MTConnectPumpGenerationChunks
{
public static MTConnectStreamsResult Pos(long first, long next, string value) =>
new(
1655000000L,
next,
first,
[new MTConnectObservation("dev1_pos", value, new DateTime(2026, 7, 24, 12, 30, 0, DateTimeKind.Utc))]);
}