Joseph Doherty 8a7668c678 fix(driver-abcip): resolve High code-review findings (Driver.AbCip-001, -002, -003, -008)
Driver.AbCip-001 — ReinitializeAsync silently discarded its config JSON.
Extracted AbCipDriverFactoryExtensions.ParseOptions; InitializeAsync now
re-parses a content-bearing driverConfigJson and replaces _options (and
recreates the alarm projection), so a reinitialize with a changed config
(new device/tag, changed timeout) actually takes effect. A blank or
empty-object JSON keeps construction-time options for the unit-test seam.

Driver.AbCip-002 — libplctag status mapping used wrong integer constants.
MapLibplctagStatus now switches on the libplctag.NET Status enum members
(Ok/Pending/ErrorTimeout/ErrorNotFound/ErrorNotAllowed/ErrorOutOfBounds/…)
instead of hand-typed natives, so timeout/not-found/not-allowed/out-of-bounds
get their specific OPC UA codes instead of all collapsing to
BadCommunicationError. The int overload casts to Status to stay correct
against the wrapper's contiguous renumbering.

Driver.AbCip-003 — whole-UDT reads decoded members at declaration-order
offsets, which Studio 5000 does not guarantee. Added the opt-in
AbCipDriverOptions.EnableDeclarationOnlyUdtGrouping flag (default false);
AbCipUdtReadPlanner.Build forms no groups when it is off, so by default
every UDT member reads per-tag rather than at possibly-wrong offsets.

Driver.AbCip-008 — probe loops were fire-and-forget and ShutdownAsync raced
them. Each probe Task is stored on DeviceState.ProbeTask; ShutdownAsync now
cancels every CTS, awaits each probe Task (10s timeout), then disposes the
CTS and handles. DeviceState.Runtimes/ParentRuntimes are ConcurrentDictionary
and the Ensure*RuntimeAsync paths use TryAdd, disposing the losing concurrent
creator instead of leaking a native tag handle.

Adds AbCipDriverCodeReviewRegressionTests and updates existing AbCip tests
to the corrected status constants + opt-in grouping flag. AbCip driver +
test project build clean; all 244 AbCip tests pass. (The full-solution
build has pre-existing, unrelated Driver.Galaxy protobuf-generation errors
in this worktree.)

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-22 06:41:25 -04:00

134 lines
5.7 KiB
C#

using Shouldly;
using Xunit;
namespace ZB.MOM.WW.OtOpcUa.Driver.AbCip.Tests;
/// <summary>
/// Task #194 — ReadAsync integration tests for the whole-UDT grouping path. The fake
/// runtime records ReadCount + surfaces member values by byte offset so we can assert
/// both "one read per parent UDT" and "each member decoded at the correct offset."
/// </summary>
[Trait("Category", "Unit")]
public sealed class AbCipDriverWholeUdtReadTests
{
private const string Device = "ab://10.0.0.5/1,0";
private static (AbCipDriver drv, FakeAbCipTagFactory factory) NewDriver(params AbCipTagDefinition[] tags)
{
var factory = new FakeAbCipTagFactory();
var opts = new AbCipDriverOptions
{
Devices = [new AbCipDeviceOptions(Device)],
Tags = tags,
// Whole-UDT grouping is opt-in (Driver.AbCip-003) — these tests exercise the
// grouping fast path, so they switch it on explicitly.
EnableDeclarationOnlyUdtGrouping = true,
};
return (new AbCipDriver(opts, "drv-1", factory), factory);
}
private static AbCipTagDefinition MotorUdt() => new(
"Motor", Device, "Motor", AbCipDataType.Structure, Members:
[
new AbCipStructureMember("Speed", AbCipDataType.DInt), // offset 0
new AbCipStructureMember("Torque", AbCipDataType.Real), // offset 4
]);
[Fact]
public async Task Two_members_of_same_udt_trigger_one_parent_read()
{
var (drv, factory) = NewDriver(MotorUdt());
await drv.InitializeAsync("{}", CancellationToken.None);
var snapshots = await drv.ReadAsync(["Motor.Speed", "Motor.Torque"], CancellationToken.None);
snapshots.Count.ShouldBe(2);
snapshots[0].StatusCode.ShouldBe(AbCipStatusMapper.Good);
snapshots[1].StatusCode.ShouldBe(AbCipStatusMapper.Good);
// Factory should have created ONE runtime (for the parent "Motor") + issued ONE read.
// Without the optimization two runtimes (one per member) + two reads would appear.
factory.Tags.Count.ShouldBe(1);
factory.Tags.ShouldContainKey("Motor");
factory.Tags["Motor"].ReadCount.ShouldBe(1);
}
[Fact]
public async Task Each_member_decodes_at_its_own_offset()
{
var (drv, factory) = NewDriver(MotorUdt());
await drv.InitializeAsync("{}", CancellationToken.None);
// Arrange the offset-keyed values before the read fires — the planner places
// Speed at offset 0 (DInt) and Torque at offset 4 (Real).
// The fake records CreationParams so we fetch it up front by the parent name.
var snapshotsTask = drv.ReadAsync(["Motor.Speed", "Motor.Torque"], CancellationToken.None);
// The factory creates the runtime inside ReadAsync; we need to set the offset map
// AFTER creation. Easier path: create the runtime on demand by reading once then
// re-arming. Instead: seed via a pre-read by constructing the fake in the factory's
// customise hook.
var snapshots = await snapshotsTask;
// First run establishes the runtime + gives the fake a chance to hold its reference.
factory.Tags["Motor"].ValuesByOffset[0] = 1234; // Speed
factory.Tags["Motor"].ValuesByOffset[4] = 9.5f; // Torque
snapshots = await drv.ReadAsync(["Motor.Speed", "Motor.Torque"], CancellationToken.None);
snapshots[0].Value.ShouldBe(1234);
snapshots[1].Value.ShouldBe(9.5f);
}
[Fact]
public async Task Parent_read_failure_stamps_every_grouped_member_Bad()
{
var (drv, factory) = NewDriver(MotorUdt());
await drv.InitializeAsync("{}", CancellationToken.None);
// Prime runtime existence via a first (successful) read so we can flip it to error.
await drv.ReadAsync(["Motor.Speed", "Motor.Torque"], CancellationToken.None);
factory.Tags["Motor"].Status = -3; // libplctag BadTimeout — mapped in AbCipStatusMapper
var snapshots = await drv.ReadAsync(["Motor.Speed", "Motor.Torque"], CancellationToken.None);
snapshots.Count.ShouldBe(2);
snapshots[0].StatusCode.ShouldNotBe(AbCipStatusMapper.Good);
snapshots[0].Value.ShouldBeNull();
snapshots[1].StatusCode.ShouldNotBe(AbCipStatusMapper.Good);
snapshots[1].Value.ShouldBeNull();
}
[Fact]
public async Task Mixed_batch_groups_udt_and_falls_back_atomics()
{
var plain = new AbCipTagDefinition("PlainDint", Device, "PlainDint", AbCipDataType.DInt);
var (drv, factory) = NewDriver(MotorUdt(), plain);
await drv.InitializeAsync("{}", CancellationToken.None);
var snapshots = await drv.ReadAsync(
["Motor.Speed", "PlainDint", "Motor.Torque"], CancellationToken.None);
snapshots.Count.ShouldBe(3);
// Motor parent ran one read, PlainDint ran its own read = 2 runtimes, 2 reads total.
factory.Tags.Count.ShouldBe(2);
factory.Tags.ShouldContainKey("Motor");
factory.Tags.ShouldContainKey("PlainDint");
factory.Tags["Motor"].ReadCount.ShouldBe(1);
factory.Tags["PlainDint"].ReadCount.ShouldBe(1);
}
[Fact]
public async Task Single_member_of_Udt_uses_per_tag_read_path()
{
// One member of a UDT doesn't benefit from grouping — the planner demotes to
// fallback so the member-level runtime (distinct from the parent runtime) is used,
// matching pre-#194 behavior.
var (drv, factory) = NewDriver(MotorUdt());
await drv.InitializeAsync("{}", CancellationToken.None);
await drv.ReadAsync(["Motor.Speed"], CancellationToken.None);
factory.Tags.ShouldContainKey("Motor.Speed");
factory.Tags.ShouldNotContainKey("Motor");
}
}