"$comment": "Copy this file to e2e-config.json and replace the NodeIds with the ones your Config DB publishes. Fields named `opcUaUrl` override the -OpcUaUrl parameter on test-all.ps1 per-driver. Omit a top-level key to skip that driver.",
|
|
|
|
"modbus": {
|
|
"$comment": "Port 5020 matches tests/.../Modbus.IntegrationTests/Docker/docker-compose.yml — `docker compose --profile standard up -d`.",
|
|
"endpoint": "127.0.0.1:5020",
|
|
"bridgeNodeId": "ns=2;s=Modbus/HR200",
|
|
"opcUaUrl": "opc.tcp://localhost:4840"
|
|
},
|
|
|
|
"abcip": {
|
|
"$comment": "ab_server listens on port 44818 (default CIP/EIP). `docker compose --profile controllogix up -d`.",
|
|
"gateway": "ab://127.0.0.1:44818/1,0",
|
|
"family": "ControlLogix",
|
|
"tagPath": "TestDINT",
|
|
"bridgeNodeId": "ns=2;s=AbCip/TestDINT"
|
|
},
|
|
|
|
"ablegacy": {
|
|
"$comment": "Works against ab_server --profile slc500 (Docker fixture) or real SLC/MicroLogix/PLC-5 hardware. `/1,0` cip-path is required for the Docker fixture; real hardware accepts an empty path — e.g. `ab://10.0.1.50:44818/`.",
|
|
"gateway": "ab://127.0.0.1/1,0",
|
|
"plcType": "Slc500",
|
|
"address": "N7:5",
|
|
"bridgeNodeId": "ns=2;s=AbLegacy/N7_5"
|
|
},
|
|
|
|
"s7": {
|
|
"$comment": "Port 1102 matches tests/.../S7.IntegrationTests/Docker/docker-compose.yml (python-snap7 needs non-priv port). `docker compose --profile s7_1500 up -d`. Real S7 PLCs listen on 102.",
|
|
"endpoint": "127.0.0.1:1102",
|
|
"cpu": "S71500",
|
|
"slot": 0,
|
|
"address": "DB1.DBW0",
|
|
"bridgeNodeId": "ns=2;s=S7/DB1_DBW0"
|
|
},
|
|
|
|
"focas": {
|
|
"$comment": "Gated behind FOCAS_TRUST_WIRE=1 — no public simulator. Point at a real CNC + ensure Fwlib32.dll is on PATH.",
|
|
"host": "192.168.1.20",
|
|
"port": 8193,
|
|
"address": "R100",
|
|
"bridgeNodeId": "ns=2;s=Focas/R100"
|
|
},
|
|
|
|
"twincat": {
|
|
"$comment": "Gated behind TWINCAT_TRUST_WIRE=1 — needs XAR or standalone TwinCAT Router NuGet reachable at -AmsNetId.",
|
|
"amsNetId": "127.0.0.1.1.1",
|
|
"amsPort": 851,
|
|
"symbolPath": "MAIN.iCounter",
|
|
"bridgeNodeId": "ns=2;s=TwinCAT/MAIN_iCounter"
|
|
},
|
|
|
|
"galaxy": {
|
|
"$comment": "Galaxy (MXAccess) driver. Has no per-driver CLI — all stages go through otopcua-cli against the published NodeIds. Seven stages: probe / source read / virtual-tag bridge / subscribe-sees-change / reverse write / alarm fires / history read. Requires OtOpcUaGalaxyHost running + seed-phase-7-smoke.sql applied with a real Galaxy attribute substituted into dbo.Tag.TagConfig.",
|
|
"sourceNodeId": "ns=2;s=p7-smoke-tag-source",
|
|
"virtualNodeId": "ns=2;s=p7-smoke-vt-derived",
|
|
"alarmNodeId": "ns=2;s=p7-smoke-al-overtemp",
|
|
"alarmTriggerValue": "75",
|
|
"changeWaitSec": 10,
|
|
"alarmWaitSec": 10,
|
|
"historyLookbackSec": 3600
|
|
},
|
|
|
|
"opcuaclient": {
|
|
"$comment": "Optional upstream-redundancy probe (PR-14). When both primaryUrl and secondaryUrl are set, test-opcuaclient.ps1 runs an extra bridged read while both upstreams are reachable. Leave keys absent to skip the redundancy stage. The OtOpcUa server's DriverConfig for the OpcUaClient instance must already have Redundancy.Enabled=true + the same EndpointUrls list; this script doesn't reconfigure the driver.",
|
|
"primaryUrl": "opc.tcp://localhost:50000",
|
|
"secondaryUrl": "opc.tcp://localhost:50002"
|
|
},
|
|
|
|
"phase7": {
|
|
"$comment": "Virtual tags + scripted alarms. The VirtualNodeId must resolve to a server-side virtual tag whose script reads the modbus InputNodeId and writes VT = input * 2. The AlarmNodeId is the ConditionId of a scripted alarm that fires when VT > 100.",
|
|
"modbusEndpoint": "127.0.0.1:5502",
|
|
"inputNodeId": "ns=2;s=Modbus/HR100",
|
|
"virtualNodeId": "ns=2;s=Virtual/VT_DoubledHR100",
|
|
"alarmNodeId": "ns=2;s=Alarm/HR100_High"
|
|
}
|
|
}
|