T
Joseph Doherty a0dccbf8ee test(drivers): tighten driver-page converter guard + clarify S7 numeric case
Code-review follow-ups: the page-coverage test now asserts every *DriverPage
declares a _jsonOpts serializer (so a new page that serialises config a
different way fails the guard, not just converter removal); clarify that 40 ==
(int)S7CpuType.S71500 in the numeric-throws test.
2026-06-19 05:06:43 -04:00

49 lines
2.4 KiB
C#

using System.Text.Json;
using System.Text.Json.Serialization;
using Shouldly;
using Xunit;
namespace ZB.MOM.WW.OtOpcUa.Driver.S7.Tests;
/// <summary>
/// Regression guard for the 2026-06-19 enum-serialization bug. The AdminUI S7 page now
/// serialises <see cref="S7CpuType"/> as a STRING (its <c>_jsonOpts</c> gained a
/// <see cref="JsonStringEnumConverter"/>). This proves the factory parses that AdminUI-shaped
/// blob and round-trips the enum, and documents that the pre-fix NUMERIC form — which the old
/// page emitted — threw because <c>S7DriverConfigDto.CpuType</c> is <c>string?</c>.
/// </summary>
public sealed class S7DriverConfigEnumSerializationTests
{
// Mirrors the (now fixed) AdminUI S7DriverPage._jsonOpts: camelCase + string enums.
private static readonly JsonSerializerOptions _adminPageOpts = new()
{
PropertyNamingPolicy = JsonNamingPolicy.CamelCase,
Converters = { new JsonStringEnumConverter() },
};
/// <summary>Verifies the factory parses an AdminUI-authored (string-enum) S7 config and
/// preserves the CpuType.</summary>
[Fact]
public void Factory_parses_admin_authored_string_enum_config()
{
var opts = new S7DriverOptions { Host = "10.0.0.5", Port = 102, CpuType = S7CpuType.S71500, Rack = 0, Slot = 1 };
var blob = JsonSerializer.Serialize(opts, _adminPageOpts);
// The fixed AdminUI page must emit the enum as a string, not a number.
blob.ShouldContain("\"cpuType\":\"S71500\"");
var parsed = S7DriverFactoryExtensions.ParseOptions("s7-test", blob);
parsed.CpuType.ShouldBe(S7CpuType.S71500);
}
/// <summary>Documents the original bug: the pre-fix AdminUI page emitted a numeric enum
/// (<c>"cpuType":40</c>) which the string-typed config DTO cannot bind, so the factory throws.</summary>
[Fact]
public void Factory_throws_on_the_numeric_enum_form_the_pre_fix_page_emitted()
{
// 40 == (int)S7CpuType.S71500 — exactly what the pre-fix page (no converter) wrote for S71500.
// The throw comes from binding a JSON number to the DTO's string? CpuType, so it fires for any number.
const string numericBlob = "{\"host\":\"10.0.0.5\",\"port\":102,\"cpuType\":40,\"rack\":0,\"slot\":1}";
Should.Throw<Exception>(() => S7DriverFactoryExtensions.ParseOptions("s7-test", numericBlob));
}
}