Files
lmxopcua/src/ZB.MOM.WW.OtOpcUa.Core/OpcUa/EquipmentNodeWalker.cs
Joseph Doherty f1f53e1789 Phase 7 Stream G — Address-space integration (NodeSourceKind + walker emits VirtualTag/ScriptedAlarm)
Per ADR-002, adds the Driver/Virtual/ScriptedAlarm discriminator to DriverAttributeInfo
so the DriverNodeManager's dispatch layer can route Read/Write/Subscribe to the right
runtime subsystem — drivers (unchanged), VirtualTagEngine (Phase 7 Stream B), or
ScriptedAlarmEngine (Phase 7 Stream C).

## Changes
- NodeSourceKind enum added to Core.Abstractions (Driver=0/Virtual=1/ScriptedAlarm=2).
- DriverAttributeInfo gains Source / VirtualTagId / ScriptedAlarmId parameters — all
  default so existing call sites (every driver) compile unchanged.
- EquipmentNamespaceContent gains VirtualTags + ScriptedAlarms optional collections.
- EquipmentNodeWalker emits:
  - Virtual-tag variables — Source=Virtual, VirtualTagId set, Historize flag honored
  - Scripted-alarm variables — Source=ScriptedAlarm, ScriptedAlarmId set, IsAlarm=true
    (triggers node-manager AlarmConditionState materialization)
  - Skips disabled virtual tags + scripted alarms

## Tests — 13/13 in EquipmentNodeWalkerTests (5 new)
- Virtual-tag variables carry Source=Virtual + VirtualTagId + Historize flag
- Scripted-alarm variables carry Source=ScriptedAlarm + IsAlarm=true + Boolean type
- Disabled rows skipped
- Null VirtualTags/ScriptedAlarms collections safe (back-compat for non-Phase-7 callers)
- Driver tags default Source=Driver (ensures no discriminator regression)

## Next
Stream G follow-up: DriverNodeManager dispatch (Read/Write/Subscribe routing by
NodeSourceKind), SealedBootstrap wiring of VirtualTagEngine + ScriptedAlarmEngine,
end-to-end integration test.
2026-04-20 19:41:01 -04:00

243 lines
13 KiB
C#

using ZB.MOM.WW.OtOpcUa.Configuration.Entities;
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
namespace ZB.MOM.WW.OtOpcUa.Core.OpcUa;
/// <summary>
/// Materializes the canonical Unified Namespace browse tree for an Equipment-kind
/// <see cref="Configuration.Entities.Namespace"/> from the Config DB's
/// <c>UnsArea</c> / <c>UnsLine</c> / <c>Equipment</c> / <c>Tag</c> rows. Runs during
/// address-space build per <see cref="IDriver"/> whose
/// <c>Namespace.Kind = Equipment</c>; SystemPlatform-kind namespaces (Galaxy) are
/// exempt per decision #120 and reach this walker only indirectly through
/// <see cref="ITagDiscovery.DiscoverAsync"/>.
/// </summary>
/// <remarks>
/// <para>
/// <b>Composition strategy.</b> ADR-001 (2026-04-20) accepted Option A — Config
/// primary. The walker treats the supplied <see cref="EquipmentNamespaceContent"/>
/// snapshot as the authoritative published surface. Every Equipment row becomes a
/// folder node at the UNS level-5 segment; every <see cref="Tag"/> bound to an
/// Equipment (non-null <see cref="Tag.EquipmentId"/>) becomes a variable node under
/// it. Driver-discovered tags that have no Config-DB row are not added by this
/// walker — the ITagDiscovery path continues to exist for the SystemPlatform case +
/// for enrichment, but Equipment-kind composition is fully Tag-row-driven.
/// </para>
///
/// <para>
/// <b>Under each Equipment node.</b> Five identifier properties per decision #121
/// (<c>EquipmentId</c>, <c>EquipmentUuid</c>, <c>MachineCode</c>, <c>ZTag</c>,
/// <c>SAPID</c>) are added as OPC UA properties — external systems (ERP, SAP PM)
/// resolve equipment by whichever identifier they natively use without a sidecar.
/// <see cref="IdentificationFolderBuilder.Build"/> materializes the OPC 40010
/// Identification sub-folder with the nine decision-#139 fields when at least one
/// is non-null; when all nine are null the sub-folder is omitted rather than
/// appearing empty.
/// </para>
///
/// <para>
/// <b>Address resolution.</b> Variable nodes carry the driver-side full reference
/// in <see cref="DriverAttributeInfo.FullName"/> copied from <c>Tag.TagConfig</c>
/// (the wire-level address JSON blob whose interpretation is driver-specific). At
/// runtime the dispatch layer routes Read/Write calls through the configured
/// capability invoker; an unreachable address surfaces as an OPC UA Bad status via
/// the natural driver-read failure path, NOT as a build-time reject. The ADR calls
/// this "BadNotFound placeholder" behavior — legible to operators via their Admin
/// UI + OPC UA client inspection of node status.
/// </para>
///
/// <para>
/// <b>Pure function.</b> This class has no dependency on the OPC UA SDK, no
/// Config-DB access, no state. It consumes pre-loaded EF Core rows + streams calls
/// into the supplied <see cref="IAddressSpaceBuilder"/>. The server-side wiring
/// (load snapshot → invoke walker → per-tag capability probe) lives in the Task B
/// PR alongside <c>NodeScopeResolver</c>'s Config-DB join.
/// </para>
/// </remarks>
public static class EquipmentNodeWalker
{
/// <summary>
/// Walk <paramref name="content"/> into <paramref name="namespaceBuilder"/>.
/// The builder is scoped to the Equipment-kind namespace root; the walker emits
/// Area → Line → Equipment folders under it, then identifier properties + the
/// Identification sub-folder + variable nodes per bound Tag under each Equipment.
/// </summary>
/// <param name="namespaceBuilder">
/// The builder scoped to the Equipment-kind namespace root. Caller is responsible for
/// creating this (e.g. <c>rootBuilder.Folder(namespace.NamespaceId, namespace.NamespaceUri)</c>).
/// </param>
/// <param name="content">Pre-loaded + pre-filtered rows for a single published generation.</param>
public static void Walk(IAddressSpaceBuilder namespaceBuilder, EquipmentNamespaceContent content)
{
ArgumentNullException.ThrowIfNull(namespaceBuilder);
ArgumentNullException.ThrowIfNull(content);
// Group lines by area + equipment by line + tags by equipment up-front. Avoids an
// O(N·M) re-scan at each UNS level on large fleets.
var linesByArea = content.Lines
.GroupBy(l => l.UnsAreaId, StringComparer.OrdinalIgnoreCase)
.ToDictionary(g => g.Key, g => g.OrderBy(l => l.Name, StringComparer.Ordinal).ToList(), StringComparer.OrdinalIgnoreCase);
var equipmentByLine = content.Equipment
.GroupBy(e => e.UnsLineId, StringComparer.OrdinalIgnoreCase)
.ToDictionary(g => g.Key, g => g.OrderBy(e => e.Name, StringComparer.Ordinal).ToList(), StringComparer.OrdinalIgnoreCase);
var tagsByEquipment = content.Tags
.Where(t => !string.IsNullOrEmpty(t.EquipmentId))
.GroupBy(t => t.EquipmentId!, StringComparer.OrdinalIgnoreCase)
.ToDictionary(g => g.Key, g => g.OrderBy(t => t.Name, StringComparer.Ordinal).ToList(), StringComparer.OrdinalIgnoreCase);
var virtualTagsByEquipment = (content.VirtualTags ?? [])
.Where(v => v.Enabled)
.GroupBy(v => v.EquipmentId, StringComparer.OrdinalIgnoreCase)
.ToDictionary(g => g.Key, g => g.OrderBy(v => v.Name, StringComparer.Ordinal).ToList(), StringComparer.OrdinalIgnoreCase);
var scriptedAlarmsByEquipment = (content.ScriptedAlarms ?? [])
.Where(a => a.Enabled)
.GroupBy(a => a.EquipmentId, StringComparer.OrdinalIgnoreCase)
.ToDictionary(g => g.Key, g => g.OrderBy(a => a.Name, StringComparer.Ordinal).ToList(), StringComparer.OrdinalIgnoreCase);
foreach (var area in content.Areas.OrderBy(a => a.Name, StringComparer.Ordinal))
{
var areaBuilder = namespaceBuilder.Folder(area.Name, area.Name);
if (!linesByArea.TryGetValue(area.UnsAreaId, out var areaLines)) continue;
foreach (var line in areaLines)
{
var lineBuilder = areaBuilder.Folder(line.Name, line.Name);
if (!equipmentByLine.TryGetValue(line.UnsLineId, out var lineEquipment)) continue;
foreach (var equipment in lineEquipment)
{
var equipmentBuilder = lineBuilder.Folder(equipment.Name, equipment.Name);
AddIdentifierProperties(equipmentBuilder, equipment);
IdentificationFolderBuilder.Build(equipmentBuilder, equipment);
if (tagsByEquipment.TryGetValue(equipment.EquipmentId, out var equipmentTags))
foreach (var tag in equipmentTags)
AddTagVariable(equipmentBuilder, tag);
if (virtualTagsByEquipment.TryGetValue(equipment.EquipmentId, out var vTags))
foreach (var vtag in vTags)
AddVirtualTagVariable(equipmentBuilder, vtag);
if (scriptedAlarmsByEquipment.TryGetValue(equipment.EquipmentId, out var alarms))
foreach (var alarm in alarms)
AddScriptedAlarmVariable(equipmentBuilder, alarm);
}
}
}
}
/// <summary>
/// Adds the five operator-facing identifiers from decision #121 as OPC UA properties
/// on the Equipment node. EquipmentId + EquipmentUuid are always populated;
/// MachineCode is required per <see cref="Equipment"/>; ZTag + SAPID are nullable in
/// the data model so they're skipped when null to avoid empty-string noise in the
/// browse tree.
/// </summary>
private static void AddIdentifierProperties(IAddressSpaceBuilder equipmentBuilder, Equipment equipment)
{
equipmentBuilder.AddProperty("EquipmentId", DriverDataType.String, equipment.EquipmentId);
equipmentBuilder.AddProperty("EquipmentUuid", DriverDataType.String, equipment.EquipmentUuid.ToString());
equipmentBuilder.AddProperty("MachineCode", DriverDataType.String, equipment.MachineCode);
if (!string.IsNullOrEmpty(equipment.ZTag))
equipmentBuilder.AddProperty("ZTag", DriverDataType.String, equipment.ZTag);
if (!string.IsNullOrEmpty(equipment.SAPID))
equipmentBuilder.AddProperty("SAPID", DriverDataType.String, equipment.SAPID);
}
/// <summary>
/// Emit a single Tag row as an <see cref="IAddressSpaceBuilder.Variable"/>. The driver
/// full reference lives in <c>Tag.TagConfig</c> (wire-level address, driver-specific
/// JSON blob); the variable node's data type derives from <c>Tag.DataType</c>.
/// Unreachable-address behavior per ADR-001 Option A: the variable is created; the
/// driver's natural Read failure surfaces an OPC UA Bad status at runtime.
/// </summary>
private static void AddTagVariable(IAddressSpaceBuilder equipmentBuilder, Tag tag)
{
var attr = new DriverAttributeInfo(
FullName: tag.TagConfig,
DriverDataType: ParseDriverDataType(tag.DataType),
IsArray: false,
ArrayDim: null,
SecurityClass: SecurityClassification.FreeAccess,
IsHistorized: false);
equipmentBuilder.Variable(tag.Name, tag.Name, attr);
}
/// <summary>
/// Parse <see cref="Tag.DataType"/> (stored as the <see cref="DriverDataType"/> enum
/// name string, decision #138) into the enum value. Unknown names fall back to
/// <see cref="DriverDataType.String"/> so a one-off driver-specific type doesn't
/// abort the whole walk; the underlying driver still sees the original TagConfig
/// address + can surface its own typed value via the OPC UA variant at read time.
/// </summary>
private static DriverDataType ParseDriverDataType(string raw) =>
Enum.TryParse<DriverDataType>(raw, ignoreCase: true, out var parsed) ? parsed : DriverDataType.String;
/// <summary>
/// Emit a <see cref="VirtualTag"/> row as a <see cref="NodeSourceKind.Virtual"/>
/// variable node. <c>FullName</c> doubles as the UNS path Phase 7's VirtualTagEngine
/// addresses its engine-side entries by. The <c>VirtualTagId</c> discriminator lets
/// the DriverNodeManager dispatch Reads/Subscribes to the engine rather than any
/// driver.
/// </summary>
private static void AddVirtualTagVariable(IAddressSpaceBuilder equipmentBuilder, VirtualTag vtag)
{
var attr = new DriverAttributeInfo(
FullName: vtag.VirtualTagId,
DriverDataType: ParseDriverDataType(vtag.DataType),
IsArray: false,
ArrayDim: null,
SecurityClass: SecurityClassification.FreeAccess,
IsHistorized: vtag.Historize,
IsAlarm: false,
WriteIdempotent: false,
Source: NodeSourceKind.Virtual,
VirtualTagId: vtag.VirtualTagId,
ScriptedAlarmId: null);
equipmentBuilder.Variable(vtag.Name, vtag.Name, attr);
}
/// <summary>
/// Emit a <see cref="ScriptedAlarm"/> row as a <see cref="NodeSourceKind.ScriptedAlarm"/>
/// variable node. The OPC UA Part 9 alarm-condition materialization happens at the
/// node-manager level (which wires the concrete <c>AlarmConditionState</c> subclass
/// per <see cref="ScriptedAlarm.AlarmType"/>); this walker provides the browse-level
/// anchor + the <see cref="DriverAttributeInfo.IsAlarm"/> flag that triggers that
/// materialization path.
/// </summary>
private static void AddScriptedAlarmVariable(IAddressSpaceBuilder equipmentBuilder, ScriptedAlarm alarm)
{
var attr = new DriverAttributeInfo(
FullName: alarm.ScriptedAlarmId,
DriverDataType: DriverDataType.Boolean,
IsArray: false,
ArrayDim: null,
SecurityClass: SecurityClassification.FreeAccess,
IsHistorized: false,
IsAlarm: true,
WriteIdempotent: false,
Source: NodeSourceKind.ScriptedAlarm,
VirtualTagId: null,
ScriptedAlarmId: alarm.ScriptedAlarmId);
equipmentBuilder.Variable(alarm.Name, alarm.Name, attr);
}
}
/// <summary>
/// Pre-loaded + pre-filtered snapshot of one Equipment-kind namespace's worth of Config
/// DB rows. All four collections are scoped to the same
/// <see cref="Configuration.Entities.ConfigGeneration"/> + the same
/// <see cref="Configuration.Entities.Namespace"/> row. The walker assumes this filter
/// was applied by the caller + does no cross-generation or cross-namespace validation.
/// </summary>
public sealed record EquipmentNamespaceContent(
IReadOnlyList<UnsArea> Areas,
IReadOnlyList<UnsLine> Lines,
IReadOnlyList<Equipment> Equipment,
IReadOnlyList<Tag> Tags,
IReadOnlyList<VirtualTag>? VirtualTags = null,
IReadOnlyList<ScriptedAlarm>? ScriptedAlarms = null);