Joseph Doherty 6d290adb37 Task #220 — AB CIP + S7 live-boot verification (5/5 stages each)
Replicated the Modbus #218 bring-up against the AB CIP + S7 seeds to
confirm the factories + seeds shipped in #217 actually work end-to-end.
Both pass 5/5 e2e stages with `OpcUaServer:AnonymousRoles=[WriteOperate]`
(the #221 knob).

## AB CIP (against ab_server controllogix fixture, port 44818)

```
=== AB CIP e2e summary: 5/5 passed ===
[PASS] Probe
[PASS] Driver loopback
[PASS] Server bridge           (driver → server → client)
[PASS] OPC UA write bridge     (client → server → driver)
[PASS] Subscribe sees change
```

Server log: `DriverInstance abcip-smoke-drv (AbCip) registered +
initialized` ✓.

## S7 (against python-snap7 s7_1500 fixture, port 1102)

```
=== S7 e2e summary: 5/5 passed ===
[PASS] Probe
[PASS] Driver loopback
[PASS] Server bridge
[PASS] OPC UA write bridge
[PASS] Subscribe sees change
```

Server log: `DriverInstance s7-smoke-drv (S7) registered + initialized` ✓.

## Seed fixes so bring-up is idempotent

Live-boot exposed two seed-level papercuts when applying multiple
smoke seeds in sequence:

1. **SA credential collision.** `UX_ClusterNodeCredential_Value` is a
   unique index on `(Kind, Value) WHERE Enabled=1`, so `sa` can only
   bind to one node at a time. Each seed's DELETE block only dropped
   the credential tied to ITS node — seeding AbCip after Modbus blew
   up with `Cannot insert duplicate key` on the sa binding. Added a
   global `DELETE FROM dbo.ClusterNodeCredential WHERE Kind='SqlLogin'
   AND Value='sa'` before the per-cluster INSERTs. Production deployments
   using non-SA logins aren't affected.

2. **DashboardPort 5000 → 15050.** `HealthEndpointsHost` uses
   `HttpListener`, which rejects port 5000 on Windows without a
   `netsh http add urlacl` grant or admin rights. 15050 is unreserved
   + loopback-safe per the HealthEndpointsHost remarks. Applied to all
   four smoke seeds (Modbus was patched at runtime in #218; now baked
   into the seed).

## AB Legacy status

Not live-boot verified — ab_server PCCC dispatcher is upstream-broken
(#222). The factory + seed ship ready for hardware; the seed's DELETE
+ DashboardPort fixes land in this PR so when real SLC/MicroLogix/PLC-5
arrives the sql just applies.

## Closes #220

Umbrella #209 was already closed; #220 was the final child.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 12:02:40 -04:00
..