Files
lmxopcua/tests
Joseph Doherty 6796ba4126 fix(historian): #688 clamp the Gateway per-sample row budget at the gateway's default ceiling
The default MaxTimeWeightedRawRows (1,000,000) + 18 exceeded the gateway's
default MaxValuesCeiling (1,000,000), so with AllowStreamingBeyondCeiling=false
every Gateway per-sample aggregate read was refused. The allowance is now clamped
at 1,000,000 while the cap is at or under it (RawAggregateReader.
ClampToGatewayCeiling); a cap above it keeps its allowance. Raw reads are not
clamped (rebased onto #686).