Joseph Doherty 95c7e0b490 Task #222 partial — unblock AB Legacy PCCC via cip-path workaround (5/5 stages)
Replaced the "ab_server PCCC upstream-broken" skip gate with the actual
root cause: libplctag's ab_server rejects empty CIP routing paths at the
unconnected-send layer before the PCCC dispatcher runs. Real SLC/
MicroLogix/PLC-5 hardware accepts empty paths (no backplane); ab_server
does not. With `/1,0` in place, N (Int16), F (Float32), and L (Int32)
file reads + writes round-trip cleanly across all three compose profiles.

## Fixture changes

- `AbLegacyServerFixture.cs`:
  - Drop `AB_LEGACY_TRUST_WIRE` env var + the reachable-but-untrusted
    skip branch. Fixture now only skips on TCP unreachability.
  - Add `AB_LEGACY_CIP_PATH` env var (default `1,0`) + expose `CipPath`
    property. Set `AB_LEGACY_CIP_PATH=` (empty) against real hardware.
  - Shorter skip messages on the `[AbLegacyFact]` / `[AbLegacyTheory]`
    attributes — one reason: endpoint not reachable.

- `AbLegacyReadSmokeTests.cs`:
  - Device URI built from `sim.CipPath` instead of hardcoded empty path.
  - New `AB_LEGACY_COMPOSE_PROFILE` env var filters the parametric
    theory to the running container's family. Only one container binds
    `:44818` at a time, so cross-family params would otherwise fail.
  - `Slc500_write_then_read_round_trip` skips cleanly when the running
    profile isn't `slc500`.

## E2E + seed + docs

- `scripts/e2e/test-ablegacy.ps1` — drop the `AB_LEGACY_TRUST_WIRE`
  skip gate; synopsis calls out the `/1,0` vs empty cip-path split
  between the Docker fixture and real hardware.
- `scripts/e2e/e2e-config.sample.json` — sample gateway flipped from
  the hardware placeholder (`192.168.1.10`) to the Docker fixture
  (`127.0.0.1/1,0`); comment rewritten.
- `scripts/e2e/README.md` — AB Legacy expected-matrix row goes from
  SKIP to PASS.
- `scripts/smoke/seed-ablegacy-smoke.sql` — default HostAddress points
  at the Docker fixture + header / footer text reflect the new state.
- `tests/.../Docker/README.md` — "Known limitations" section rewritten
  to describe the cip-path gate (not a dispatcher gap); env-var table
  picks up `AB_LEGACY_CIP_PATH` + `AB_LEGACY_COMPOSE_PROFILE`.
- `docs/drivers/AbLegacy-Test-Fixture.md` + `docs/drivers/README.md`
  + `docs/DriverClis.md` — flip status from blocked to functional;
  residual bit-file-write gap (B3:0/5 → 0x803D0000) documented.

## Residual gap

Bit-file writes (`B3:0/5` style) surface `0x803D0000` against
`ab_server --plc=SLC500`; bit reads work. Non-blocking for smoke
coverage — N/F/L round-trip is enough. Real hardware / RSEmulate 500
for bit-write fidelity. Documented in `Docker/README.md` §"Known
limitations" + the `AbLegacy-Test-Fixture.md` follow-ups list.

## Verified

- Full-solution build: 0 errors, 334 pre-existing warnings.
- Integration suite passes per-profile with
  `AB_LEGACY_COMPOSE_PROFILE=<slc500|micrologix|plc5>` + matching
  compose container up.
- All four non-hardware e2e scripts (Modbus / AB CIP / AB Legacy / S7)
  now 5/5 against the respective docker-compose fixtures.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 12:38:43 -04:00

100 lines
3.4 KiB
PowerShell

#Requires -Version 7.0
<#
.SYNOPSIS
End-to-end CLI test for the AB Legacy (PCCC) driver.
.DESCRIPTION
Runs against libplctag's ab_server PCCC Docker fixture (one of the
slc500 / micrologix / plc5 compose profiles) or real SLC / MicroLogix /
PLC-5 hardware. Five assertions: probe / driver-loopback / forward-
bridge / reverse-bridge / subscribe-sees-change.
ab_server enforces a non-empty CIP routing path (`/1,0`) before the
PCCC dispatcher runs; real hardware accepts an empty path. The default
$Gateway uses `/1,0` for the Docker fixture — pass `-Gateway
"ab://host:44818/"` when pointing at a real SLC 5/05 / MicroLogix /
PLC-5.
.PARAMETER Gateway
ab://host[:port]/cip-path. Default ab://127.0.0.1/1,0 (Docker fixture).
.PARAMETER PlcType
Slc500 / MicroLogix / Plc5 / LogixPccc (default Slc500).
.PARAMETER Address
PCCC address to exercise. Default N7:5.
.PARAMETER OpcUaUrl
OtOpcUa server endpoint.
.PARAMETER BridgeNodeId
NodeId at which the server publishes the Address.
#>
param(
[string]$Gateway = "ab://127.0.0.1/1,0",
[string]$PlcType = "Slc500",
[string]$Address = "N7:5",
[string]$OpcUaUrl = "opc.tcp://localhost:4840",
[Parameter(Mandatory)] [string]$BridgeNodeId
)
$ErrorActionPreference = "Stop"
. "$PSScriptRoot/_common.ps1"
# ab_server PCCC works; the earlier "upstream-broken" gate is gone. The only
# caveat: libplctag's ab_server rejects empty CIP paths, so $Gateway must
# carry a non-empty path segment (default /1,0). Real SLC/PLC-5 hardware
# accepts an empty path — use `ab://host:44818/` when pointing at real PLCs.
$abLegacyCli = Get-CliInvocation `
-ProjectFolder "src/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Cli" `
-ExeName "otopcua-ablegacy-cli"
$opcUaCli = Get-CliInvocation `
-ProjectFolder "src/ZB.MOM.WW.OtOpcUa.Client.CLI" `
-ExeName "otopcua-cli"
$commonAbLegacy = @("-g", $Gateway, "-P", $PlcType)
$results = @()
$results += Test-Probe `
-Cli $abLegacyCli `
-ProbeArgs (@("probe") + $commonAbLegacy + @("-a", "N7:0"))
$writeValue = Get-Random -Minimum 1 -Maximum 9999
$results += Test-DriverLoopback `
-Cli $abLegacyCli `
-WriteArgs (@("write") + $commonAbLegacy + @("-a", $Address, "-t", "Int", "-v", $writeValue)) `
-ReadArgs (@("read") + $commonAbLegacy + @("-a", $Address, "-t", "Int")) `
-ExpectedValue "$writeValue"
$bridgeValue = Get-Random -Minimum 10000 -Maximum 19999
$results += Test-ServerBridge `
-DriverCli $abLegacyCli `
-DriverWriteArgs (@("write") + $commonAbLegacy + @("-a", $Address, "-t", "Int", "-v", $bridgeValue)) `
-OpcUaCli $opcUaCli `
-OpcUaUrl $OpcUaUrl `
-OpcUaNodeId $BridgeNodeId `
-ExpectedValue "$bridgeValue"
$reverseValue = Get-Random -Minimum 20000 -Maximum 29999
$results += Test-OpcUaWriteBridge `
-OpcUaCli $opcUaCli `
-OpcUaUrl $OpcUaUrl `
-OpcUaNodeId $BridgeNodeId `
-DriverCli $abLegacyCli `
-DriverReadArgs (@("read") + $commonAbLegacy + @("-a", $Address, "-t", "Int")) `
-ExpectedValue "$reverseValue"
$subValue = Get-Random -Minimum 30000 -Maximum 32766
$results += Test-SubscribeSeesChange `
-OpcUaCli $opcUaCli `
-OpcUaUrl $OpcUaUrl `
-OpcUaNodeId $BridgeNodeId `
-DriverCli $abLegacyCli `
-DriverWriteArgs (@("write") + $commonAbLegacy + @("-a", $Address, "-t", "Int", "-v", $subValue)) `
-ExpectedValue "$subValue"
Write-Summary -Title "AB Legacy e2e" -Results $results
if ($results | Where-Object { -not $_.Passed }) { exit 1 }