751786ec8c
A DriverInstanceActor stuck Reconnecting/Connecting now adopts a config delivered via ApplyDelta and re-initialises with it, instead of dead-lettering and retrying the stale config forever. A monotonic init generation supersedes the in-flight init so the corrected config always wins.