Joseph Doherty e5122c546b Auto: s7-a5 — LOGO!/S7-200 V-memory parser
Add CPU-aware overload S7AddressParser.Parse(string, CpuType?) that
accepts the V area letter for S7-200 / S7-200 Smart / LOGO! 0BA8 and
maps it to DataBlock DB1. V is rejected on S7-300/400/1200/1500 and on
the legacy CPU-agnostic Parse(string) overload. Width suffixes mirror
M/I/Q (VB/VW/VD/V0.0). S7Driver passes _options.CpuType so live tag
config picks up family-aware parsing.

Tests cover S7200/S7200Smart/Logo0BA8 positive cases, modern-family
rejection, and CPU-agnostic rejection.

Closes #291
2026-04-25 16:58:34 -04:00

957 lines
47 KiB
C#
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
using System.Buffers.Binary;
using S7.Net;
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
namespace ZB.MOM.WW.OtOpcUa.Driver.S7;
/// <summary>
/// Siemens S7 native driver — speaks S7comm over ISO-on-TCP (port 102) via the S7netplus
/// library. First implementation of <see cref="IDriver"/> for an in-process .NET Standard
/// PLC protocol that is NOT Modbus, validating that the v2 driver-capability interfaces
/// generalize beyond Modbus + Galaxy.
/// </summary>
/// <remarks>
/// <para>
/// PR 62 ships the scaffold: <see cref="IDriver"/> only (Initialize / Reinitialize /
/// Shutdown / GetHealth). <see cref="ITagDiscovery"/>, <see cref="IReadable"/>,
/// <see cref="IWritable"/>, <see cref="ISubscribable"/>, <see cref="IHostConnectivityProbe"/>
/// land in PRs 63-65 once the address parser (PR 63) is in place.
/// </para>
/// <para>
/// <b>Single-connection policy</b>: S7netplus documented pattern is one
/// <c>Plc</c> instance per PLC, serialized with a <see cref="SemaphoreSlim"/>.
/// Parallelising reads against a single S7 CPU doesn't help — the CPU scans the
/// communication mailbox at most once per cycle (2-10 ms) and queues concurrent
/// requests wire-side anyway. Multiple client-side connections just waste the CPU's
/// 8-64 connection-resource budget.
/// </para>
/// </remarks>
public sealed class S7Driver(S7DriverOptions options, string driverInstanceId)
: IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IDisposable, IAsyncDisposable
{
// ---- ISubscribable + IHostConnectivityProbe state ----
private readonly System.Collections.Concurrent.ConcurrentDictionary<long, SubscriptionState> _subscriptions = new();
private long _nextSubscriptionId;
private readonly object _probeLock = new();
private HostState _hostState = HostState.Unknown;
private DateTime _hostStateChangedUtc = DateTime.UtcNow;
private CancellationTokenSource? _probeCts;
public event EventHandler<DataChangeEventArgs>? OnDataChange;
public event EventHandler<HostStatusChangedEventArgs>? OnHostStatusChanged;
/// <summary>OPC UA StatusCode used when the tag name isn't in the driver's tag map.</summary>
private const uint StatusBadNodeIdUnknown = 0x80340000u;
/// <summary>OPC UA StatusCode used when the tag's data type isn't implemented yet.</summary>
private const uint StatusBadNotSupported = 0x803D0000u;
/// <summary>OPC UA StatusCode used when the tag is declared read-only.</summary>
private const uint StatusBadNotWritable = 0x803B0000u;
/// <summary>OPC UA StatusCode used when write fails validation (e.g. out-of-range value).</summary>
private const uint StatusBadInternalError = 0x80020000u;
/// <summary>OPC UA StatusCode used for socket / timeout / protocol-layer faults.</summary>
private const uint StatusBadCommunicationError = 0x80050000u;
/// <summary>OPC UA StatusCode used when S7 returns <c>ErrorCode.WrongCPU</c> / PUT/GET disabled.</summary>
private const uint StatusBadDeviceFailure = 0x80550000u;
/// <summary>
/// Hard upper bound on <see cref="S7TagDefinition.ElementCount"/>. The S7 PDU envelope
/// for negotiated default 240-byte and extended 960-byte payloads cannot fit a single
/// byte-range read larger than ~960 bytes, so a Float64 array of more than ~120
/// elements is already lossy. 8000 is an order-of-magnitude generous ceiling that still
/// rejects obvious config typos (e.g. ElementCount = 65535) at init time.
/// </summary>
internal const int MaxArrayElements = 8000;
private readonly Dictionary<string, S7TagDefinition> _tagsByName = new(StringComparer.OrdinalIgnoreCase);
private readonly Dictionary<string, S7ParsedAddress> _parsedByName = new(StringComparer.OrdinalIgnoreCase);
private readonly S7DriverOptions _options = options;
private readonly SemaphoreSlim _gate = new(1, 1);
/// <summary>
/// Per-connection gate. Internal so PRs 63-65 (read/write/subscribe) can serialize on
/// the same semaphore without exposing it publicly. Single-connection-per-PLC is a
/// hard requirement of S7netplus — see class remarks.
/// </summary>
internal SemaphoreSlim Gate => _gate;
/// <summary>
/// Active S7.Net PLC connection. Null until <see cref="InitializeAsync"/> returns; null
/// after <see cref="ShutdownAsync"/>. Read-only outside this class; PR 64's Read/Write
/// will take the <see cref="_gate"/> before touching it.
/// </summary>
internal Plc? Plc { get; private set; }
private DriverHealth _health = new(DriverState.Unknown, null, null);
private bool _disposed;
public string DriverInstanceId => driverInstanceId;
public string DriverType => "S7";
public async Task InitializeAsync(string driverConfigJson, CancellationToken cancellationToken)
{
_health = new DriverHealth(DriverState.Initializing, null, null);
try
{
// Parse + validate every tag before opening the TCP socket so config bugs
// (bad address, oversized array, unsupported array element) surface as
// FormatException without waiting on a connect timeout. Per the v1 driver-config
// story this lets the Admin UI's "Save" round-trip stay sub-second on bad input.
_tagsByName.Clear();
_parsedByName.Clear();
foreach (var t in _options.Tags)
{
// Pass CpuType so V-memory addresses (S7-200 / S7-200 Smart / LOGO!) resolve
// against the device's family-specific DB mapping.
var parsed = S7AddressParser.Parse(t.Address, _options.CpuType); // throws FormatException
if (t.ElementCount is int n && n > 1)
{
// Array sanity: cap at S7 PDU realistic limit, reject variable-width
// element types and BOOL (packed-bit layout) up-front so a config typo
// fails at init instead of surfacing as BadInternalError on every read.
if (n > MaxArrayElements)
throw new FormatException(
$"S7 tag '{t.Name}' ElementCount {n} exceeds S7 PDU realistic limit ({MaxArrayElements})");
if (!IsArrayElementSupported(t.DataType))
throw new FormatException(
$"S7 tag '{t.Name}' DataType {t.DataType} not supported as an array element " +
$"(variable-width string types and BOOL packed-bit arrays are a follow-up)");
}
_tagsByName[t.Name] = t;
_parsedByName[t.Name] = parsed;
}
var plc = new Plc(_options.CpuType, _options.Host, _options.Port, _options.Rack, _options.Slot);
// S7netplus writes timeouts into the underlying TcpClient via Plc.WriteTimeout /
// Plc.ReadTimeout (milliseconds). Set before OpenAsync so the handshake itself
// honours the bound.
plc.WriteTimeout = (int)_options.Timeout.TotalMilliseconds;
plc.ReadTimeout = (int)_options.Timeout.TotalMilliseconds;
using var cts = CancellationTokenSource.CreateLinkedTokenSource(cancellationToken);
cts.CancelAfter(_options.Timeout);
await plc.OpenAsync(cts.Token).ConfigureAwait(false);
Plc = plc;
_health = new DriverHealth(DriverState.Healthy, DateTime.UtcNow, null);
// Kick off the probe loop once the connection is up. Initial HostState stays
// Unknown until the first probe tick succeeds — avoids broadcasting a premature
// Running transition before any PDU round-trip has happened.
if (_options.Probe.Enabled)
{
_probeCts = new CancellationTokenSource();
_ = Task.Run(() => ProbeLoopAsync(_probeCts.Token), _probeCts.Token);
}
}
catch (Exception ex)
{
// Clean up a partially-constructed Plc so a retry from the caller doesn't leak
// the TcpClient. S7netplus's Close() is best-effort and idempotent.
try { Plc?.Close(); } catch { }
Plc = null;
_health = new DriverHealth(DriverState.Faulted, null, ex.Message);
throw;
}
}
public async Task ReinitializeAsync(string driverConfigJson, CancellationToken cancellationToken)
{
await ShutdownAsync(cancellationToken).ConfigureAwait(false);
await InitializeAsync(driverConfigJson, cancellationToken).ConfigureAwait(false);
}
public Task ShutdownAsync(CancellationToken cancellationToken)
{
try { _probeCts?.Cancel(); } catch { }
_probeCts?.Dispose();
_probeCts = null;
foreach (var state in _subscriptions.Values)
{
try { state.Cts.Cancel(); } catch { }
state.Cts.Dispose();
}
_subscriptions.Clear();
try { Plc?.Close(); } catch { /* best-effort — tearing down anyway */ }
Plc = null;
_health = new DriverHealth(DriverState.Unknown, _health.LastSuccessfulRead, null);
return Task.CompletedTask;
}
public DriverHealth GetHealth() => _health;
/// <summary>
/// Approximate memory footprint. The Plc instance + one 240-960 byte PDU buffer is
/// under 4 KB; return 0 because the <see cref="IDriver"/> contract asks for a
/// driver-attributable growth number and S7.Net doesn't expose one.
/// </summary>
public long GetMemoryFootprint() => 0;
public Task FlushOptionalCachesAsync(CancellationToken cancellationToken) => Task.CompletedTask;
// ---- IReadable ----
public async Task<IReadOnlyList<DataValueSnapshot>> ReadAsync(
IReadOnlyList<string> fullReferences, CancellationToken cancellationToken)
{
var plc = RequirePlc();
var now = DateTime.UtcNow;
var results = new DataValueSnapshot[fullReferences.Count];
await _gate.WaitAsync(cancellationToken).ConfigureAwait(false);
try
{
for (var i = 0; i < fullReferences.Count; i++)
{
var name = fullReferences[i];
if (!_tagsByName.TryGetValue(name, out var tag))
{
results[i] = new DataValueSnapshot(null, StatusBadNodeIdUnknown, null, now);
continue;
}
try
{
var value = await ReadOneAsync(plc, tag, cancellationToken).ConfigureAwait(false);
results[i] = new DataValueSnapshot(value, 0u, now, now);
_health = new DriverHealth(DriverState.Healthy, now, null);
}
catch (NotSupportedException)
{
results[i] = new DataValueSnapshot(null, StatusBadNotSupported, null, now);
}
catch (global::S7.Net.PlcException pex)
{
// S7.Net's PlcException carries an ErrorCode; PUT/GET-disabled on
// S7-1200/1500 surfaces here. Map to BadDeviceFailure so operators see a
// device-config problem (toggle PUT/GET in TIA Portal) rather than a
// transient fault — per driver-specs.md §5.
results[i] = new DataValueSnapshot(null, StatusBadDeviceFailure, null, now);
_health = new DriverHealth(DriverState.Degraded, _health.LastSuccessfulRead, pex.Message);
}
catch (Exception ex)
{
results[i] = new DataValueSnapshot(null, StatusBadCommunicationError, null, now);
_health = new DriverHealth(DriverState.Degraded, _health.LastSuccessfulRead, ex.Message);
}
}
}
finally { _gate.Release(); }
return results;
}
private async Task<object> ReadOneAsync(global::S7.Net.Plc plc, S7TagDefinition tag, CancellationToken ct)
{
var addr = _parsedByName[tag.Name];
// 1-D array path: one byte-range read covering N×elementBytes, sliced client-side.
// Init-time validation guarantees only fixed-width element types reach here.
if (tag.ElementCount is int n && n > 1)
{
var elemBytes = ArrayElementBytes(tag.DataType);
var totalBytes = checked(n * elemBytes);
if (addr.Size == S7Size.Bit)
throw new System.IO.InvalidDataException(
$"S7 Read type-mismatch: tag '{tag.Name}' is array of {tag.DataType} but address '{tag.Address}' " +
$"parsed as bit-access; arrays require byte-addressing");
var arrBytes = await plc.ReadBytesAsync(MapArea(addr.Area), addr.DbNumber, addr.ByteOffset, totalBytes, ct)
.ConfigureAwait(false);
if (arrBytes is null || arrBytes.Length != totalBytes)
throw new System.IO.InvalidDataException(
$"S7.Net returned {arrBytes?.Length ?? 0} bytes for array '{tag.Address}' (n={n}), expected {totalBytes}");
return SliceArray(arrBytes, tag.DataType, n, elemBytes);
}
// String-shaped types (STRING/WSTRING/CHAR/WCHAR): S7.Net's string-keyed ReadAsync
// has no syntax for these, so the driver issues a raw byte read and decodes via
// S7StringCodec. Wire order is big-endian for the WSTRING/WCHAR UTF-16 payload.
if (tag.DataType is S7DataType.String or S7DataType.WString or S7DataType.Char or S7DataType.WChar)
{
if (addr.Size == S7Size.Bit)
throw new System.IO.InvalidDataException(
$"S7 Read type-mismatch: tag '{tag.Name}' declared {tag.DataType} but address '{tag.Address}' " +
$"parsed as bit-access; string-shaped types require byte-addressing (e.g. DBB / MB / IB / QB)");
var (area, dbNum, off) = (addr.Area, addr.DbNumber, addr.ByteOffset);
switch (tag.DataType)
{
case S7DataType.Char:
{
var b = await plc.ReadBytesAsync(MapArea(area), dbNum, off, 1, ct).ConfigureAwait(false);
if (b is null || b.Length != 1)
throw new System.IO.InvalidDataException($"S7.Net returned {b?.Length ?? 0} bytes for CHAR '{tag.Address}', expected 1");
return S7StringCodec.DecodeChar(b);
}
case S7DataType.WChar:
{
var b = await plc.ReadBytesAsync(MapArea(area), dbNum, off, 2, ct).ConfigureAwait(false);
if (b is null || b.Length != 2)
throw new System.IO.InvalidDataException($"S7.Net returned {b?.Length ?? 0} bytes for WCHAR '{tag.Address}', expected 2");
return S7StringCodec.DecodeWChar(b);
}
case S7DataType.String:
{
var max = tag.StringLength;
var size = S7StringCodec.StringBufferSize(max);
var b = await plc.ReadBytesAsync(MapArea(area), dbNum, off, size, ct).ConfigureAwait(false);
if (b is null || b.Length != size)
throw new System.IO.InvalidDataException($"S7.Net returned {b?.Length ?? 0} bytes for STRING '{tag.Address}', expected {size}");
return S7StringCodec.DecodeString(b, max);
}
case S7DataType.WString:
{
var max = tag.StringLength;
var size = S7StringCodec.WStringBufferSize(max);
var b = await plc.ReadBytesAsync(MapArea(area), dbNum, off, size, ct).ConfigureAwait(false);
if (b is null || b.Length != size)
throw new System.IO.InvalidDataException($"S7.Net returned {b?.Length ?? 0} bytes for WSTRING '{tag.Address}', expected {size}");
return S7StringCodec.DecodeWString(b, max);
}
}
}
// Date/time-shaped types (DTL/DT/S5TIME/TIME/TOD/DATE): S7.Net has no native size
// suffix for any of these, so the driver issues a raw byte read at the address's
// ByteOffset and decodes via S7DateTimeCodec. All require byte-addressing — bit-
// access against a date/time tag is a config bug worth surfacing as a hard error.
if (tag.DataType is S7DataType.Dtl or S7DataType.DateAndTime or S7DataType.S5Time
or S7DataType.Time or S7DataType.TimeOfDay or S7DataType.Date)
{
if (addr.Size == S7Size.Bit)
throw new System.IO.InvalidDataException(
$"S7 Read type-mismatch: tag '{tag.Name}' declared {tag.DataType} but address '{tag.Address}' " +
$"parsed as bit-access; date/time types require byte-addressing");
int size = tag.DataType switch
{
S7DataType.Dtl => S7DateTimeCodec.DtlSize,
S7DataType.DateAndTime => S7DateTimeCodec.DtSize,
S7DataType.S5Time => S7DateTimeCodec.S5TimeSize,
S7DataType.Time => S7DateTimeCodec.TimeSize,
S7DataType.TimeOfDay => S7DateTimeCodec.TodSize,
S7DataType.Date => S7DateTimeCodec.DateSize,
_ => throw new InvalidOperationException(),
};
var b = await plc.ReadBytesAsync(MapArea(addr.Area), addr.DbNumber, addr.ByteOffset, size, ct).ConfigureAwait(false);
if (b is null || b.Length != size)
throw new System.IO.InvalidDataException(
$"S7.Net returned {b?.Length ?? 0} bytes for {tag.DataType} '{tag.Address}', expected {size}");
return tag.DataType switch
{
S7DataType.Dtl => S7DateTimeCodec.DecodeDtl(b),
S7DataType.DateAndTime => S7DateTimeCodec.DecodeDt(b),
// S5TIME/TIME/TOD surface as Int32 ms — DriverDataType has no Duration type;
// OPC UA clients see a millisecond integer matching the IEC-1131 convention.
S7DataType.S5Time => (int)S7DateTimeCodec.DecodeS5Time(b).TotalMilliseconds,
S7DataType.Time => (int)S7DateTimeCodec.DecodeTime(b).TotalMilliseconds,
S7DataType.TimeOfDay => (int)S7DateTimeCodec.DecodeTod(b).TotalMilliseconds,
S7DataType.Date => S7DateTimeCodec.DecodeDate(b),
_ => throw new InvalidOperationException(),
};
}
// 64-bit types: S7.Net's string-based ReadAsync has no LWord size suffix, so issue an
// 8-byte ReadBytesAsync and convert big-endian in-process. Wire order on S7 is BE.
if (tag.DataType is S7DataType.Int64 or S7DataType.UInt64 or S7DataType.Float64)
{
if (addr.Size != S7Size.LWord)
throw new System.IO.InvalidDataException(
$"S7 Read type-mismatch: tag '{tag.Name}' declared {tag.DataType} but address '{tag.Address}' " +
$"parsed as Size={addr.Size}; 64-bit types require an LD/DBL/DBLD suffix");
var bytes = await plc.ReadBytesAsync(MapArea(addr.Area), addr.DbNumber, addr.ByteOffset, 8, ct)
.ConfigureAwait(false);
if (bytes is null || bytes.Length != 8)
throw new System.IO.InvalidDataException($"S7.Net returned {bytes?.Length ?? 0} bytes for '{tag.Address}', expected 8");
return tag.DataType switch
{
S7DataType.Int64 => BinaryPrimitives.ReadInt64BigEndian(bytes),
S7DataType.UInt64 => BinaryPrimitives.ReadUInt64BigEndian(bytes),
S7DataType.Float64 => BitConverter.UInt64BitsToDouble(BinaryPrimitives.ReadUInt64BigEndian(bytes)),
_ => throw new InvalidOperationException(),
};
}
// S7.Net's string-based ReadAsync returns object where the boxed .NET type depends on
// the size suffix: DBX=bool, DBB=byte, DBW=ushort, DBD=uint. Our S7DataType enum
// specifies the SEMANTIC type (Int16 vs UInt16 vs Float32 etc.); the reinterpret below
// converts the raw unsigned boxed value into the requested type without issuing an
// extra PLC round-trip.
var raw = await plc.ReadAsync(tag.Address, ct).ConfigureAwait(false)
?? throw new System.IO.InvalidDataException($"S7.Net returned null for '{tag.Address}'");
return (tag.DataType, addr.Size, raw) switch
{
(S7DataType.Bool, S7Size.Bit, bool b) => b,
(S7DataType.Byte, S7Size.Byte, byte by) => by,
(S7DataType.UInt16, S7Size.Word, ushort u16) => u16,
(S7DataType.Int16, S7Size.Word, ushort u16) => unchecked((short)u16),
(S7DataType.UInt32, S7Size.DWord, uint u32) => u32,
(S7DataType.Int32, S7Size.DWord, uint u32) => unchecked((int)u32),
(S7DataType.Float32, S7Size.DWord, uint u32) => BitConverter.UInt32BitsToSingle(u32),
(S7DataType.DateTime, _, _) => throw new NotSupportedException("S7 DateTime reads land in a follow-up PR"),
_ => throw new System.IO.InvalidDataException(
$"S7 Read type-mismatch: tag '{tag.Name}' declared {tag.DataType} but address '{tag.Address}' " +
$"parsed as Size={addr.Size}; S7.Net returned {raw.GetType().Name}"),
};
}
/// <summary>Map driver-internal <see cref="S7Area"/> to S7.Net's <see cref="global::S7.Net.DataType"/>.</summary>
private static global::S7.Net.DataType MapArea(S7Area area) => area switch
{
S7Area.DataBlock => global::S7.Net.DataType.DataBlock,
S7Area.Memory => global::S7.Net.DataType.Memory,
S7Area.Input => global::S7.Net.DataType.Input,
S7Area.Output => global::S7.Net.DataType.Output,
S7Area.Timer => global::S7.Net.DataType.Timer,
S7Area.Counter => global::S7.Net.DataType.Counter,
_ => throw new InvalidOperationException($"Unknown S7Area {area}"),
};
// ---- IWritable ----
public async Task<IReadOnlyList<WriteResult>> WriteAsync(
IReadOnlyList<WriteRequest> writes, CancellationToken cancellationToken)
{
var plc = RequirePlc();
var results = new WriteResult[writes.Count];
await _gate.WaitAsync(cancellationToken).ConfigureAwait(false);
try
{
for (var i = 0; i < writes.Count; i++)
{
var w = writes[i];
if (!_tagsByName.TryGetValue(w.FullReference, out var tag))
{
results[i] = new WriteResult(StatusBadNodeIdUnknown);
continue;
}
if (!tag.Writable)
{
results[i] = new WriteResult(StatusBadNotWritable);
continue;
}
try
{
await WriteOneAsync(plc, tag, w.Value, cancellationToken).ConfigureAwait(false);
results[i] = new WriteResult(0u);
}
catch (NotSupportedException)
{
results[i] = new WriteResult(StatusBadNotSupported);
}
catch (global::S7.Net.PlcException)
{
results[i] = new WriteResult(StatusBadDeviceFailure);
}
catch (Exception)
{
results[i] = new WriteResult(StatusBadInternalError);
}
}
}
finally { _gate.Release(); }
return results;
}
private async Task WriteOneAsync(global::S7.Net.Plc plc, S7TagDefinition tag, object? value, CancellationToken ct)
{
// 1-D array path: pack all N elements into a single buffer then push via WriteBytesAsync.
// Init-time validation guarantees only fixed-width element types reach here.
if (tag.ElementCount is int n && n > 1)
{
var addr = _parsedByName[tag.Name];
if (addr.Size == S7Size.Bit)
throw new InvalidOperationException(
$"S7 Write type-mismatch: tag '{tag.Name}' is array of {tag.DataType} but address '{tag.Address}' " +
$"parsed as bit-access; arrays require byte-addressing");
if (value is null)
throw new ArgumentNullException(nameof(value));
var elemBytes = ArrayElementBytes(tag.DataType);
var buf = PackArray(value, tag.DataType, n, elemBytes, tag.Name);
await plc.WriteBytesAsync(MapArea(addr.Area), addr.DbNumber, addr.ByteOffset, buf, ct).ConfigureAwait(false);
return;
}
// String-shaped types: encode via S7StringCodec then push via WriteBytesAsync. The
// codec rejects out-of-range lengths and non-ASCII for CHAR — we let the resulting
// ArgumentException bubble out so the WriteAsync caller maps it to BadInternalError.
if (tag.DataType is S7DataType.String or S7DataType.WString or S7DataType.Char or S7DataType.WChar)
{
var addr = _parsedByName[tag.Name];
if (addr.Size == S7Size.Bit)
throw new InvalidOperationException(
$"S7 Write type-mismatch: tag '{tag.Name}' declared {tag.DataType} but address '{tag.Address}' " +
$"parsed as bit-access; string-shaped types require byte-addressing (e.g. DBB / MB / IB / QB)");
byte[] payload = tag.DataType switch
{
S7DataType.Char => S7StringCodec.EncodeChar(Convert.ToChar(value ?? throw new ArgumentNullException(nameof(value)))),
S7DataType.WChar => S7StringCodec.EncodeWChar(Convert.ToChar(value ?? throw new ArgumentNullException(nameof(value)))),
S7DataType.String => S7StringCodec.EncodeString(Convert.ToString(value) ?? string.Empty, tag.StringLength),
S7DataType.WString => S7StringCodec.EncodeWString(Convert.ToString(value) ?? string.Empty, tag.StringLength),
_ => throw new InvalidOperationException(),
};
await plc.WriteBytesAsync(MapArea(addr.Area), addr.DbNumber, addr.ByteOffset, payload, ct).ConfigureAwait(false);
return;
}
// Date/time-shaped types: encode via S7DateTimeCodec and push as raw bytes. S5TIME /
// TIME / TOD accept an integer-ms input (matching the read surface); DTL / DT / DATE
// accept a DateTime. ArgumentException from the codec bubbles to BadInternalError.
if (tag.DataType is S7DataType.Dtl or S7DataType.DateAndTime or S7DataType.S5Time
or S7DataType.Time or S7DataType.TimeOfDay or S7DataType.Date)
{
var addr = _parsedByName[tag.Name];
if (addr.Size == S7Size.Bit)
throw new InvalidOperationException(
$"S7 Write type-mismatch: tag '{tag.Name}' declared {tag.DataType} but address '{tag.Address}' " +
$"parsed as bit-access; date/time types require byte-addressing");
if (value is null)
throw new ArgumentNullException(nameof(value));
byte[] payload = tag.DataType switch
{
S7DataType.Dtl => S7DateTimeCodec.EncodeDtl(Convert.ToDateTime(value)),
S7DataType.DateAndTime => S7DateTimeCodec.EncodeDt(Convert.ToDateTime(value)),
S7DataType.S5Time => S7DateTimeCodec.EncodeS5Time(value is TimeSpan ts1 ? ts1 : TimeSpan.FromMilliseconds(Convert.ToInt32(value))),
S7DataType.Time => S7DateTimeCodec.EncodeTime(value is TimeSpan ts2 ? ts2 : TimeSpan.FromMilliseconds(Convert.ToInt32(value))),
S7DataType.TimeOfDay => S7DateTimeCodec.EncodeTod(value is TimeSpan ts3 ? ts3 : TimeSpan.FromMilliseconds(Convert.ToInt64(value))),
S7DataType.Date => S7DateTimeCodec.EncodeDate(Convert.ToDateTime(value)),
_ => throw new InvalidOperationException(),
};
await plc.WriteBytesAsync(MapArea(addr.Area), addr.DbNumber, addr.ByteOffset, payload, ct).ConfigureAwait(false);
return;
}
// 64-bit types: S7.Net has no LWord-aware WriteAsync(string, object) overload, so emit
// the value as 8 big-endian bytes via WriteBytesAsync. Wire order on S7 is BE so a
// BinaryPrimitives.Write*BigEndian round-trips with the matching ReadOneAsync path.
if (tag.DataType is S7DataType.Int64 or S7DataType.UInt64 or S7DataType.Float64)
{
var addr = _parsedByName[tag.Name];
if (addr.Size != S7Size.LWord)
throw new InvalidOperationException(
$"S7 Write type-mismatch: tag '{tag.Name}' declared {tag.DataType} but address '{tag.Address}' " +
$"parsed as Size={addr.Size}; 64-bit types require an LD/DBL/DBLD suffix");
var buf = new byte[8];
switch (tag.DataType)
{
case S7DataType.Int64:
BinaryPrimitives.WriteInt64BigEndian(buf, Convert.ToInt64(value));
break;
case S7DataType.UInt64:
BinaryPrimitives.WriteUInt64BigEndian(buf, Convert.ToUInt64(value));
break;
case S7DataType.Float64:
BinaryPrimitives.WriteUInt64BigEndian(buf, BitConverter.DoubleToUInt64Bits(Convert.ToDouble(value)));
break;
}
await plc.WriteBytesAsync(MapArea(addr.Area), addr.DbNumber, addr.ByteOffset, buf, ct).ConfigureAwait(false);
return;
}
// S7.Net's Plc.WriteAsync(string address, object value) expects the boxed value to
// match the address's size-suffix type: DBX=bool, DBB=byte, DBW=ushort, DBD=uint.
// Our S7DataType lets the caller pass short/int/float; convert to the unsigned
// wire representation before handing off.
var boxed = tag.DataType switch
{
S7DataType.Bool => (object)Convert.ToBoolean(value),
S7DataType.Byte => (object)Convert.ToByte(value),
S7DataType.UInt16 => (object)Convert.ToUInt16(value),
S7DataType.Int16 => (object)unchecked((ushort)Convert.ToInt16(value)),
S7DataType.UInt32 => (object)Convert.ToUInt32(value),
S7DataType.Int32 => (object)unchecked((uint)Convert.ToInt32(value)),
S7DataType.Float32 => (object)BitConverter.SingleToUInt32Bits(Convert.ToSingle(value)),
S7DataType.DateTime => throw new NotSupportedException("S7 DateTime writes land in a follow-up PR"),
_ => throw new InvalidOperationException($"Unknown S7DataType {tag.DataType}"),
};
await plc.WriteAsync(tag.Address, boxed, ct).ConfigureAwait(false);
}
private global::S7.Net.Plc RequirePlc() =>
Plc ?? throw new InvalidOperationException("S7Driver not initialized");
// ---- ITagDiscovery ----
public Task DiscoverAsync(IAddressSpaceBuilder builder, CancellationToken cancellationToken)
{
ArgumentNullException.ThrowIfNull(builder);
var folder = builder.Folder("S7", "S7");
foreach (var t in _options.Tags)
{
var isArr = t.ElementCount is int ec && ec > 1;
folder.Variable(t.Name, t.Name, new DriverAttributeInfo(
FullName: t.Name,
DriverDataType: MapDataType(t.DataType),
IsArray: isArr,
ArrayDim: isArr ? (uint)t.ElementCount!.Value : null,
SecurityClass: t.Writable ? SecurityClassification.Operate : SecurityClassification.ViewOnly,
IsHistorized: false,
IsAlarm: false,
WriteIdempotent: t.WriteIdempotent));
}
return Task.CompletedTask;
}
/// <summary>
/// True when <paramref name="t"/> can be used as an array element. Variable-width string
/// types and BOOL (packed-bit layout) are rejected — both need bespoke addressing
/// beyond a flat <c>N × elementBytes</c> byte-range read and ship as a follow-up.
/// </summary>
internal static bool IsArrayElementSupported(S7DataType t) => t is
S7DataType.Byte or
S7DataType.Int16 or S7DataType.UInt16 or
S7DataType.Int32 or S7DataType.UInt32 or
S7DataType.Int64 or S7DataType.UInt64 or
S7DataType.Float32 or S7DataType.Float64 or
S7DataType.Date or S7DataType.Time or S7DataType.TimeOfDay;
/// <summary>
/// On-wire bytes per array element for the supported fixed-width element types. DATE
/// is a 16-bit days-since-1990 counter, TIME and TOD are 32-bit ms counters.
/// </summary>
internal static int ArrayElementBytes(S7DataType t) => t switch
{
S7DataType.Byte => 1,
S7DataType.Int16 or S7DataType.UInt16 or S7DataType.Date => 2,
S7DataType.Int32 or S7DataType.UInt32 or S7DataType.Float32
or S7DataType.Time or S7DataType.TimeOfDay => 4,
S7DataType.Int64 or S7DataType.UInt64 or S7DataType.Float64 => 8,
_ => throw new InvalidOperationException($"S7 array element bytes undefined for {t}"),
};
/// <summary>
/// Slice a flat S7 byte buffer into a typed array using the existing big-endian scalar
/// codec for each element. Returns the typed array boxed as <c>object</c> so the
/// <see cref="DataValueSnapshot"/> surface can carry it without further conversion.
/// </summary>
internal static object SliceArray(byte[] bytes, S7DataType t, int n, int elemBytes)
{
switch (t)
{
case S7DataType.Byte:
{
var a = new byte[n];
Buffer.BlockCopy(bytes, 0, a, 0, n);
return a;
}
case S7DataType.Int16:
{
var a = new short[n];
for (var i = 0; i < n; i++) a[i] = BinaryPrimitives.ReadInt16BigEndian(bytes.AsSpan(i * elemBytes, 2));
return a;
}
case S7DataType.UInt16:
{
var a = new ushort[n];
for (var i = 0; i < n; i++) a[i] = BinaryPrimitives.ReadUInt16BigEndian(bytes.AsSpan(i * elemBytes, 2));
return a;
}
case S7DataType.Int32:
{
var a = new int[n];
for (var i = 0; i < n; i++) a[i] = BinaryPrimitives.ReadInt32BigEndian(bytes.AsSpan(i * elemBytes, 4));
return a;
}
case S7DataType.UInt32:
{
var a = new uint[n];
for (var i = 0; i < n; i++) a[i] = BinaryPrimitives.ReadUInt32BigEndian(bytes.AsSpan(i * elemBytes, 4));
return a;
}
case S7DataType.Int64:
{
var a = new long[n];
for (var i = 0; i < n; i++) a[i] = BinaryPrimitives.ReadInt64BigEndian(bytes.AsSpan(i * elemBytes, 8));
return a;
}
case S7DataType.UInt64:
{
var a = new ulong[n];
for (var i = 0; i < n; i++) a[i] = BinaryPrimitives.ReadUInt64BigEndian(bytes.AsSpan(i * elemBytes, 8));
return a;
}
case S7DataType.Float32:
{
var a = new float[n];
for (var i = 0; i < n; i++)
a[i] = BitConverter.UInt32BitsToSingle(BinaryPrimitives.ReadUInt32BigEndian(bytes.AsSpan(i * elemBytes, 4)));
return a;
}
case S7DataType.Float64:
{
var a = new double[n];
for (var i = 0; i < n; i++)
a[i] = BitConverter.UInt64BitsToDouble(BinaryPrimitives.ReadUInt64BigEndian(bytes.AsSpan(i * elemBytes, 8)));
return a;
}
case S7DataType.Date:
{
var a = new DateTime[n];
for (var i = 0; i < n; i++)
a[i] = S7DateTimeCodec.DecodeDate(bytes.AsSpan(i * elemBytes, 2));
return a;
}
case S7DataType.Time:
{
// Surface as Int32 ms — matches the scalar Time read path (driver-specs §5).
var a = new int[n];
for (var i = 0; i < n; i++)
a[i] = (int)S7DateTimeCodec.DecodeTime(bytes.AsSpan(i * elemBytes, 4)).TotalMilliseconds;
return a;
}
case S7DataType.TimeOfDay:
{
var a = new int[n];
for (var i = 0; i < n; i++)
a[i] = (int)S7DateTimeCodec.DecodeTod(bytes.AsSpan(i * elemBytes, 4)).TotalMilliseconds;
return a;
}
default:
throw new InvalidOperationException($"S7 array slice undefined for {t}");
}
}
/// <summary>
/// Pack a caller-supplied array (object) into the on-wire S7 byte layout for
/// <paramref name="elementType"/>. Accepts both the strongly-typed array
/// (<c>short[]</c>, <c>int[]</c>, ...) and a generic <c>System.Array</c> / <c>IEnumerable</c>
/// so OPC UA Variant-boxed values flow through unchanged.
/// </summary>
internal static byte[] PackArray(object value, S7DataType elementType, int n, int elemBytes, string tagName)
{
if (value is not System.Collections.IEnumerable enumerable)
throw new ArgumentException($"S7 Write tag '{tagName}' is array but value is not enumerable (got {value.GetType().Name})", nameof(value));
var buf = new byte[n * elemBytes];
var i = 0;
foreach (var raw in enumerable)
{
if (i >= n)
throw new ArgumentException($"S7 Write tag '{tagName}': value has more than ElementCount={n} elements", nameof(value));
var span = buf.AsSpan(i * elemBytes, elemBytes);
switch (elementType)
{
case S7DataType.Byte: span[0] = Convert.ToByte(raw); break;
case S7DataType.Int16: BinaryPrimitives.WriteInt16BigEndian(span, Convert.ToInt16(raw)); break;
case S7DataType.UInt16: BinaryPrimitives.WriteUInt16BigEndian(span, Convert.ToUInt16(raw)); break;
case S7DataType.Int32: BinaryPrimitives.WriteInt32BigEndian(span, Convert.ToInt32(raw)); break;
case S7DataType.UInt32: BinaryPrimitives.WriteUInt32BigEndian(span, Convert.ToUInt32(raw)); break;
case S7DataType.Int64: BinaryPrimitives.WriteInt64BigEndian(span, Convert.ToInt64(raw)); break;
case S7DataType.UInt64: BinaryPrimitives.WriteUInt64BigEndian(span, Convert.ToUInt64(raw)); break;
case S7DataType.Float32: BinaryPrimitives.WriteUInt32BigEndian(span, BitConverter.SingleToUInt32Bits(Convert.ToSingle(raw))); break;
case S7DataType.Float64: BinaryPrimitives.WriteUInt64BigEndian(span, BitConverter.DoubleToUInt64Bits(Convert.ToDouble(raw))); break;
case S7DataType.Date:
S7DateTimeCodec.EncodeDate(Convert.ToDateTime(raw)).CopyTo(span);
break;
case S7DataType.Time:
S7DateTimeCodec.EncodeTime(raw is TimeSpan ts ? ts : TimeSpan.FromMilliseconds(Convert.ToInt32(raw))).CopyTo(span);
break;
case S7DataType.TimeOfDay:
S7DateTimeCodec.EncodeTod(raw is TimeSpan tod ? tod : TimeSpan.FromMilliseconds(Convert.ToInt64(raw))).CopyTo(span);
break;
default:
throw new InvalidOperationException($"S7 array pack undefined for {elementType}");
}
i++;
}
if (i != n)
throw new ArgumentException($"S7 Write tag '{tagName}': value had {i} elements, expected ElementCount={n}", nameof(value));
return buf;
}
private static DriverDataType MapDataType(S7DataType t) => t switch
{
S7DataType.Bool => DriverDataType.Boolean,
S7DataType.Byte => DriverDataType.Int32, // no 8-bit in DriverDataType yet
S7DataType.Int16 => DriverDataType.Int16,
S7DataType.UInt16 => DriverDataType.UInt16,
S7DataType.Int32 => DriverDataType.Int32,
S7DataType.UInt32 => DriverDataType.UInt32,
S7DataType.Int64 => DriverDataType.Int64,
S7DataType.UInt64 => DriverDataType.UInt64,
S7DataType.Float32 => DriverDataType.Float32,
S7DataType.Float64 => DriverDataType.Float64,
S7DataType.String => DriverDataType.String,
S7DataType.WString => DriverDataType.String,
S7DataType.Char => DriverDataType.String,
S7DataType.WChar => DriverDataType.String,
S7DataType.DateTime => DriverDataType.DateTime,
S7DataType.Dtl => DriverDataType.DateTime,
S7DataType.DateAndTime => DriverDataType.DateTime,
S7DataType.Date => DriverDataType.DateTime,
// S5TIME/TIME/TOD have no Duration type in DriverDataType — surface as Int32 ms
// (matching the IEC-1131 representation).
S7DataType.S5Time => DriverDataType.Int32,
S7DataType.Time => DriverDataType.Int32,
S7DataType.TimeOfDay => DriverDataType.Int32,
_ => DriverDataType.Int32,
};
// ---- ISubscribable (polling overlay) ----
public Task<ISubscriptionHandle> SubscribeAsync(
IReadOnlyList<string> fullReferences, TimeSpan publishingInterval, CancellationToken cancellationToken)
{
var id = Interlocked.Increment(ref _nextSubscriptionId);
var cts = new CancellationTokenSource();
// Floor at 100 ms — S7 CPUs scan 2-10 ms but the comms mailbox is processed at most
// once per scan; sub-100 ms polling just queues wire-side with worse latency.
var interval = publishingInterval < TimeSpan.FromMilliseconds(100)
? TimeSpan.FromMilliseconds(100)
: publishingInterval;
var handle = new S7SubscriptionHandle(id);
var state = new SubscriptionState(handle, [.. fullReferences], interval, cts);
_subscriptions[id] = state;
_ = Task.Run(() => PollLoopAsync(state, cts.Token), cts.Token);
return Task.FromResult<ISubscriptionHandle>(handle);
}
public Task UnsubscribeAsync(ISubscriptionHandle handle, CancellationToken cancellationToken)
{
if (handle is S7SubscriptionHandle h && _subscriptions.TryRemove(h.Id, out var state))
{
state.Cts.Cancel();
state.Cts.Dispose();
}
return Task.CompletedTask;
}
private async Task PollLoopAsync(SubscriptionState state, CancellationToken ct)
{
// Initial-data push per OPC UA Part 4 convention.
try { await PollOnceAsync(state, forceRaise: true, ct).ConfigureAwait(false); }
catch (OperationCanceledException) { return; }
catch { /* first-read error — polling continues */ }
while (!ct.IsCancellationRequested)
{
try { await Task.Delay(state.Interval, ct).ConfigureAwait(false); }
catch (OperationCanceledException) { return; }
try { await PollOnceAsync(state, forceRaise: false, ct).ConfigureAwait(false); }
catch (OperationCanceledException) { return; }
catch { /* transient polling error — loop continues, health surface reflects it */ }
}
}
private async Task PollOnceAsync(SubscriptionState state, bool forceRaise, CancellationToken ct)
{
var snapshots = await ReadAsync(state.TagReferences, ct).ConfigureAwait(false);
for (var i = 0; i < state.TagReferences.Count; i++)
{
var tagRef = state.TagReferences[i];
var current = snapshots[i];
var lastSeen = state.LastValues.TryGetValue(tagRef, out var prev) ? prev : default;
if (forceRaise || !Equals(lastSeen?.Value, current.Value) || lastSeen?.StatusCode != current.StatusCode)
{
state.LastValues[tagRef] = current;
OnDataChange?.Invoke(this, new DataChangeEventArgs(state.Handle, tagRef, current));
}
}
}
private sealed record SubscriptionState(
S7SubscriptionHandle Handle,
IReadOnlyList<string> TagReferences,
TimeSpan Interval,
CancellationTokenSource Cts)
{
public System.Collections.Concurrent.ConcurrentDictionary<string, DataValueSnapshot> LastValues { get; }
= new(StringComparer.OrdinalIgnoreCase);
}
private sealed record S7SubscriptionHandle(long Id) : ISubscriptionHandle
{
public string DiagnosticId => $"s7-sub-{Id}";
}
// ---- IHostConnectivityProbe ----
/// <summary>
/// Host identifier surfaced in <see cref="GetHostStatuses"/>. <c>host:port</c> format
/// matches the Modbus driver's convention so the Admin UI dashboard renders both
/// family's rows uniformly.
/// </summary>
public string HostName => $"{_options.Host}:{_options.Port}";
public IReadOnlyList<HostConnectivityStatus> GetHostStatuses()
{
lock (_probeLock)
return [new HostConnectivityStatus(HostName, _hostState, _hostStateChangedUtc)];
}
private async Task ProbeLoopAsync(CancellationToken ct)
{
while (!ct.IsCancellationRequested)
{
var success = false;
try
{
// Probe via S7.Net's low-cost GetCpuStatus — returns the CPU state (Run/Stop)
// and is intentionally light on the comms mailbox. Single-word Plc.ReadAsync
// would also work but GetCpuStatus doubles as a "PLC actually up" check.
using var probeCts = CancellationTokenSource.CreateLinkedTokenSource(ct);
probeCts.CancelAfter(_options.Probe.Timeout);
var plc = Plc;
if (plc is null) throw new InvalidOperationException("Plc dropped during probe");
await _gate.WaitAsync(probeCts.Token).ConfigureAwait(false);
try
{
_ = await plc.ReadStatusAsync(probeCts.Token).ConfigureAwait(false);
success = true;
}
finally { _gate.Release(); }
}
catch (OperationCanceledException) when (ct.IsCancellationRequested) { return; }
catch { /* transport/timeout/exception — treated as Stopped below */ }
TransitionTo(success ? HostState.Running : HostState.Stopped);
try { await Task.Delay(_options.Probe.Interval, ct).ConfigureAwait(false); }
catch (OperationCanceledException) { return; }
}
}
private void TransitionTo(HostState newState)
{
HostState old;
lock (_probeLock)
{
old = _hostState;
if (old == newState) return;
_hostState = newState;
_hostStateChangedUtc = DateTime.UtcNow;
}
OnHostStatusChanged?.Invoke(this, new HostStatusChangedEventArgs(HostName, old, newState));
}
public void Dispose() => DisposeAsync().AsTask().GetAwaiter().GetResult();
public async ValueTask DisposeAsync()
{
if (_disposed) return;
_disposed = true;
try { await ShutdownAsync(CancellationToken.None).ConfigureAwait(false); }
catch { /* disposal is best-effort */ }
_gate.Dispose();
}
}