lmxopcua/tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests/ModbusCapTests.cs
Joseph Doherty a3f2f95344 Phase 3 PR 49 -- Per-device FC03/FC16 register caps with auto-chunking. Adds MaxRegistersPerRead (default 125, spec max) + MaxRegistersPerWrite (default 123, spec max) to ModbusDriverOptions. Reads that exceed the cap automatically split into consecutive FC03 requests: the driver dispatches chunks of [cap] regs at incrementing addresses, copies each response into an assembled byte[] buffer, and hands the full payload to DecodeRegister. From the caller's view a 240-char string read against a cap-100 device is still one Read() call returning one string -- the chunking is invisible, the wire shows N requests of cap-sized quantity plus one tail chunk. Writes are NOT auto-chunked. Splitting an FC16 across two transactions would lose atomicity -- mid-split crash leaves half the value written, which is strictly worse than rejecting upfront. Instead, writes exceeding MaxRegistersPerWrite throw InvalidOperationException with a message naming the tag + cap + the caller's escape hatch (shorten StringLength or split into multiple tags). The driver catches the exception internally and surfaces it to IWritable as BadInternalError so the caller pattern stays symmetric with other failure modes. Per-family cap cheat-sheet (documented in xml-doc on the option): Modbus-TCP spec = 125 read / 123 write, AutomationDirect DL205/DL260 = 128 read / 100 write (128 exceeds spec byte-count capacity so in practice 125 is the working ceiling), Mitsubishi Q/FX3U = 64 / 64, Omron CJ/CS = 125 / 123. Not all PLCs reject over-cap requests cleanly -- some drop the connection silently -- so having the cap enforced client-side prevents the hard-to-diagnose 'driver just stopped' failure mode. Unit tests: Read_within_cap_issues_single_FC03_request (control: no unnecessary chunking), Read_above_cap_splits_into_two_FC03_requests (120 regs / cap 100 -> 100+20, asserts exact per-chunk (Address,Quantity) and end-to-end payload continuity starting with register[100] high byte = 'A'), Read_cap_honors_Mitsubishi_lower_cap_of_64 (100 regs / cap 64 -> 64+36), Write_exceeding_cap_throws_instead_of_splitting (110 regs / cap 100 -> status != 0 AND Fc16Requests.Count == 0 to prove nothing was sent), Write_within_cap_proceeds_normally (control: cap honored on short writes too). Tests use a new RecordingTransport that captures the (Address, Quantity) tuple of every FC03/FC16 request so the chunk layout is directly assertable -- the existing FakeTransport does not expose request history. 103/103 Modbus.Tests pass; 6/6 DL205 integration tests still pass against the live pymodbus dl205 profile with MODBUS_SIM_PROFILE=dl205.
2026-04-18 21:58:49 -04:00

166 lines
7.7 KiB
C#

using Shouldly;
using Xunit;
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests;
[Trait("Category", "Unit")]
public sealed class ModbusCapTests
{
/// <summary>
/// Records every PDU sent so tests can assert request-count and per-request quantity —
/// the only observable behaviour of the auto-chunking path.
/// </summary>
private sealed class RecordingTransport : IModbusTransport
{
public readonly ushort[] HoldingRegisters = new ushort[1024];
public readonly List<(ushort Address, ushort Quantity)> Fc03Requests = new();
public readonly List<(ushort Address, ushort Quantity)> Fc16Requests = new();
public Task ConnectAsync(CancellationToken ct) => Task.CompletedTask;
public Task<byte[]> SendAsync(byte unitId, byte[] pdu, CancellationToken ct)
{
var fc = pdu[0];
if (fc == 0x03)
{
var addr = (ushort)((pdu[1] << 8) | pdu[2]);
var qty = (ushort)((pdu[3] << 8) | pdu[4]);
Fc03Requests.Add((addr, qty));
var byteCount = (byte)(qty * 2);
var resp = new byte[2 + byteCount];
resp[0] = 0x03;
resp[1] = byteCount;
for (var i = 0; i < qty; i++)
{
resp[2 + i * 2] = (byte)(HoldingRegisters[addr + i] >> 8);
resp[3 + i * 2] = (byte)(HoldingRegisters[addr + i] & 0xFF);
}
return Task.FromResult(resp);
}
if (fc == 0x10)
{
var addr = (ushort)((pdu[1] << 8) | pdu[2]);
var qty = (ushort)((pdu[3] << 8) | pdu[4]);
Fc16Requests.Add((addr, qty));
for (var i = 0; i < qty; i++)
HoldingRegisters[addr + i] = (ushort)((pdu[6 + i * 2] << 8) | pdu[7 + i * 2]);
return Task.FromResult(new byte[] { 0x10, pdu[1], pdu[2], pdu[3], pdu[4] });
}
return Task.FromException<byte[]>(new ModbusException(fc, 0x01, $"fc={fc} unsupported"));
}
public ValueTask DisposeAsync() => ValueTask.CompletedTask;
}
[Fact]
public async Task Read_within_cap_issues_single_FC03_request()
{
var tag = new ModbusTagDefinition("S", ModbusRegion.HoldingRegisters, 0, ModbusDataType.String,
StringLength: 40); // 20 regs — fits in default cap (125).
var transport = new RecordingTransport();
var opts = new ModbusDriverOptions { Host = "fake", Tags = [tag], Probe = new ModbusProbeOptions { Enabled = false } };
await using var drv = new ModbusDriver(opts, "modbus-1", _ => transport);
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken);
_ = await drv.ReadAsync(["S"], TestContext.Current.CancellationToken);
transport.Fc03Requests.Count.ShouldBe(1);
transport.Fc03Requests[0].Quantity.ShouldBe((ushort)20);
}
[Fact]
public async Task Read_above_cap_splits_into_two_FC03_requests()
{
// 240-char string = 120 regs. Cap = 100 (a typical sub-spec device cap). Expect 100 + 20.
var tag = new ModbusTagDefinition("LongString", ModbusRegion.HoldingRegisters, 100, ModbusDataType.String,
StringLength: 240);
var transport = new RecordingTransport();
// Seed cells so the re-assembled payload is stable — confirms chunks are stitched in order.
for (ushort i = 100; i < 100 + 120; i++)
transport.HoldingRegisters[i] = (ushort)((('A' + (i - 100) % 26) << 8) | ('A' + (i - 100) % 26));
var opts = new ModbusDriverOptions
{
Host = "fake",
Tags = [tag],
MaxRegistersPerRead = 100,
Probe = new ModbusProbeOptions { Enabled = false },
};
await using var drv = new ModbusDriver(opts, "modbus-1", _ => transport);
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken);
var results = await drv.ReadAsync(["LongString"], TestContext.Current.CancellationToken);
results[0].StatusCode.ShouldBe(0u);
transport.Fc03Requests.Count.ShouldBe(2, "120 regs / cap 100 → 2 requests");
transport.Fc03Requests[0].ShouldBe(((ushort)100, (ushort)100));
transport.Fc03Requests[1].ShouldBe(((ushort)200, (ushort)20));
// Payload continuity: re-assembled string starts where register 100 does and keeps going.
var s = (string)results[0].Value!;
s.Length.ShouldBeGreaterThan(0);
s[0].ShouldBe('A'); // register[100] high byte
}
[Fact]
public async Task Read_cap_honors_Mitsubishi_lower_cap_of_64()
{
// 200-char string = 100 regs. Mitsubishi Q cap = 64. Expect: 64, 36.
var tag = new ModbusTagDefinition("MitString", ModbusRegion.HoldingRegisters, 0, ModbusDataType.String,
StringLength: 200);
var transport = new RecordingTransport();
var opts = new ModbusDriverOptions { Host = "fake", Tags = [tag], MaxRegistersPerRead = 64, Probe = new ModbusProbeOptions { Enabled = false } };
await using var drv = new ModbusDriver(opts, "modbus-1", _ => transport);
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken);
_ = await drv.ReadAsync(["MitString"], TestContext.Current.CancellationToken);
transport.Fc03Requests.Count.ShouldBe(2);
transport.Fc03Requests[0].Quantity.ShouldBe((ushort)64);
transport.Fc03Requests[1].Quantity.ShouldBe((ushort)36);
}
[Fact]
public async Task Write_exceeding_cap_throws_instead_of_splitting()
{
// Partial FC16 across two transactions is not atomic. Forcing an explicit exception so the
// caller knows their tag definition is incompatible with the device cap rather than silently
// writing half a string and crashing between chunks.
var tag = new ModbusTagDefinition("LongStringWrite", ModbusRegion.HoldingRegisters, 0, ModbusDataType.String,
StringLength: 220); // 110 regs.
var transport = new RecordingTransport();
var opts = new ModbusDriverOptions { Host = "fake", Tags = [tag], MaxRegistersPerWrite = 100, Probe = new ModbusProbeOptions { Enabled = false } };
await using var drv = new ModbusDriver(opts, "modbus-1", _ => transport);
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken);
var results = await drv.WriteAsync(
[new WriteRequest("LongStringWrite", new string('A', 220))],
TestContext.Current.CancellationToken);
// Driver catches the internal exception and surfaces BadInternalError — the Fc16Requests
// list must still be empty because nothing was sent.
results[0].StatusCode.ShouldNotBe(0u);
transport.Fc16Requests.Count.ShouldBe(0);
}
[Fact]
public async Task Write_within_cap_proceeds_normally()
{
var tag = new ModbusTagDefinition("ShortStringWrite", ModbusRegion.HoldingRegisters, 0, ModbusDataType.String,
StringLength: 40); // 20 regs.
var transport = new RecordingTransport();
var opts = new ModbusDriverOptions { Host = "fake", Tags = [tag], MaxRegistersPerWrite = 100, Probe = new ModbusProbeOptions { Enabled = false } };
await using var drv = new ModbusDriver(opts, "modbus-1", _ => transport);
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken);
var results = await drv.WriteAsync(
[new WriteRequest("ShortStringWrite", "HELLO")],
TestContext.Current.CancellationToken);
results[0].StatusCode.ShouldBe(0u);
transport.Fc16Requests.Count.ShouldBe(1);
transport.Fc16Requests[0].Quantity.ShouldBe((ushort)20);
}
}