Joseph Doherty 56bb4855bb fix(historian): #671 review — raw-row cap, reverse Interpolative, SDK status rule, Partial bit
M1: the time-weighted family (incl. Total, formerly a pushed-down SUM) streams
raw window rows into the C# evaluator. New shared knob
ServerHistorian:MaxTimeWeightedRawRows (default 1,000,000; <=0 unbounded with a
Validate warning) flows through HistorianBackendRegistry into both providers.
The window query is capped at cap+1 (SQL Server TOP (@maxRows), QuestDB LIMIT $4);
one row past the cap throws the new Core.Abstractions
HistoryReadLimitExceededException, which the node manager maps to
BadTooManyOperations for that node. Not counted as a backend health failure;
bound rows are not counted; per-sample aggregates are not capped.

M2: reverse Interpolative is anchored at the later time (Part 13): points at
End - i*interval, emitted latest first. 10:00->09:00 @1h yields 10:00.

L1: Partial bit (0x4, = Opc.Ua.AggregateBits.Partial) on non-Bad results of a
truncated last interval (time-weighted family; per-sample family is a follow-up).

L2/L3: aligned with the SDK AggregateCalculator.GetTimeBasedStatusCode
(decompiled from Opc.Ua.Server 1.5.378.106): TreatUncertainAsBad=false counts
Uncertain time (Uncertain samples, held-into-outage, extrapolation) as Good
time; data but no non-Bad time => generic Bad (0x80000000); BadNoData only
when there is no data at all. Consequence: a live tag's latest interval reads
Good (documented).

L5: release note no longer claims Total matches the Gateway Integral exactly
(AVEVA's divisor is unverified); it notes Total is now evaluated in C# and
subject to the cap.

Tests: unit (reverse Interpolative x3, Partial, Bad vs BadNoData incl. an
open-ended outage, cap helpers, SDK bit oracles); conformance (reverse
Interpolative, raw-row cap at/over/0, bounds not counted, health unaffected);
node manager BadTooManyOperations; options default + warning. Each new
behaviour falsified by mutation (aggregator x9, data-source cap checks on
both backends against the real DBs, node-manager catch).
2026-10-11 09:10:26 -04:00

54 lines
2.4 KiB
C#

using Shouldly;
using Xunit;
namespace ZB.MOM.WW.OtOpcUa.Driver.Historian.Sql.Common.Tests;
/// <summary>The pinned SDK is the oracle for the info-bit constants (StatusCodeParityTests covers the named codes).</summary>
public sealed class StatusCodeOracleTests
{
[Fact]
public void Calculated_bits_match_the_SDK()
{
var sdk = new Opc.Ua.StatusCode(Opc.Ua.StatusCodes.Good).SetAggregateBits(Opc.Ua.AggregateBits.Calculated);
sdk.Code.ShouldBe(HistorianInfoBits.WithCalculated(HistorianStatusCodes.Good));
((uint)Opc.Ua.AggregateBits.Calculated).ShouldBe(HistorianInfoBits.HistorianCalculated);
}
[Fact]
public void Interpolated_bits_match_the_SDK()
{
var sdk = new Opc.Ua.StatusCode(Opc.Ua.StatusCodes.Good).SetAggregateBits(Opc.Ua.AggregateBits.Interpolated);
sdk.Code.ShouldBe(HistorianInfoBits.WithInterpolated(HistorianStatusCodes.Good));
((uint)Opc.Ua.AggregateBits.Interpolated).ShouldBe(HistorianInfoBits.HistorianInterpolated);
}
/// <summary>
/// A stored status that already carries a historian bit (a sample written via HistoryUpdate with the Calculated
/// bit, say) must come back with ONE historian bit, never both: the existing pair is masked off first. The SDK
/// agrees — <c>SetAggregateBits</c> replaces, it does not OR.
/// </summary>
[Fact]
public void Setting_one_historian_bit_clears_the_other()
{
var calculatedUncertain = HistorianStatusCodes.UncertainDataSubNormal | 0x400u | HistorianInfoBits.HistorianCalculated;
var interpolated = HistorianInfoBits.WithInterpolated(calculatedUncertain);
interpolated.ShouldBe(HistorianStatusCodes.UncertainDataSubNormal | 0x400u | HistorianInfoBits.HistorianInterpolated);
new Opc.Ua.StatusCode(interpolated).AggregateBits.ShouldBe(Opc.Ua.AggregateBits.Interpolated);
var interpolatedGood = 0x400u | HistorianInfoBits.HistorianInterpolated;
HistorianInfoBits.WithCalculated(interpolatedGood).ShouldBe(0x400u | HistorianInfoBits.HistorianCalculated);
}
[Fact]
public void Partial_bit_matches_the_SDK() =>
((uint)Opc.Ua.AggregateBits.Partial).ShouldBe(HistorianInfoBits.HistorianPartial);
[Fact]
public void Generic_bad_matches_the_SDK() =>
HistorianStatusCodes.Bad.ShouldBe(Opc.Ua.StatusCodes.Bad);
[Fact]
public void Info_type_is_data_value() =>