Ran the driver CLIs against the live docker-compose fixtures to debug
what actually works. Two real bugs surfaced:
1. `e2e-config.sample.json` pointed at the wrong simulator ports:
- Modbus: 5502 → **5020** (pymodbus compose binding)
- S7: 102 → **1102** (python-snap7, non-priv port)
- AbCip: no port → now explicit **:44818**
`test-modbus.ps1` default `-ModbusHost` also shipped with 5502;
fixed to 5020.
2. Modbus loopback was off-by-2 because pymodbus `standard.json` makes
HR[100] an auto-increment register (value ticks on every poll).
Switched `test-modbus.ps1` to **HR[200]** (scratch range in the
profile) + updated sample config `bridgeNodeId` to match.
Also fixed the AbCip probe: `-t @raw_cpu_type` was rejected by the
driver's TagPath parser ("malformed TagPath"). Probe now uses the
user-supplied `-TagPath` for every family. Works against both
ab_server and real controllers.
Verified driver-side against live containers:
- Modbus 5020: probe ✓, HR[200] write+read round-trip ✓
- AB CIP 44818: probe ✓, TestDINT write+read round-trip ✓
- S7 1102: probe ✓, DB1.DBW0 write+read round-trip ✓
## Known blocker (stages 3-5)
README now flags — and the 4 child issues under umbrella #209 track —
that `src/ZB.MOM.WW.OtOpcUa.Server/Program.cs:98-104` only registers
Galaxy + FOCAS driver factories. `DriverInstanceBootstrapper` silently
skips any `DriverType` without a registered factory, so stages 3-5
(anything crossing the OPC UA server) can't work today even with a
perfect Config DB seed. Issues #210-213 scope the factory + seed SQL
work per driver.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
100 lines
3.6 KiB
PowerShell
100 lines
3.6 KiB
PowerShell
#Requires -Version 7.0
|
|
<#
|
|
.SYNOPSIS
|
|
End-to-end CLI test for the Modbus-TCP driver bridged through the OtOpcUa server.
|
|
|
|
.DESCRIPTION
|
|
Five assertions:
|
|
1. `otopcua-modbus-cli probe` hits the simulator
|
|
2. Driver-loopback write + read-back via modbus-cli
|
|
3. Forward bridge: modbus-cli writes HR[200], OPC UA client reads the bridged NodeId
|
|
4. Reverse bridge: OPC UA client writes the NodeId, modbus-cli reads HR[200]
|
|
5. Subscribe-sees-change: OPC UA subscription observes a modbus-cli write
|
|
|
|
Requires a running Modbus simulator on localhost:5020 (the pymodbus fixture
|
|
default — see tests/.../Modbus.IntegrationTests/Docker/docker-compose.yml)
|
|
and a running OtOpcUa server whose config DB has a Modbus DriverInstance
|
|
bound to that simulator + a Tag at HR[200] UInt16 published under the
|
|
NodeId passed via -BridgeNodeId.
|
|
|
|
NOTE: HR[200] (not HR[100]) — pymodbus standard.json makes HR[100] an
|
|
auto-incrementing register that mutates every poll, so loopback writes
|
|
can't be verified there.
|
|
|
|
.PARAMETER ModbusHost
|
|
Host:port of the Modbus simulator. Default 127.0.0.1:5020.
|
|
|
|
.PARAMETER OpcUaUrl
|
|
Endpoint URL of the OtOpcUa server. Default opc.tcp://localhost:4840.
|
|
|
|
.PARAMETER BridgeNodeId
|
|
OPC UA NodeId the OtOpcUa server publishes the HR[100] tag at. Set per your
|
|
server config — e.g. 'ns=2;s=/warsaw/modbus-sim/HR_100'. Required.
|
|
|
|
.EXAMPLE
|
|
.\test-modbus.ps1 -BridgeNodeId "ns=2;s=/warsaw/modbus-sim/HR_100"
|
|
#>
|
|
|
|
param(
|
|
[string]$ModbusHost = "127.0.0.1:5020",
|
|
[string]$OpcUaUrl = "opc.tcp://localhost:4840",
|
|
[Parameter(Mandatory)] [string]$BridgeNodeId
|
|
)
|
|
|
|
$ErrorActionPreference = "Stop"
|
|
. "$PSScriptRoot/_common.ps1"
|
|
|
|
$hostPart, $portPart = $ModbusHost.Split(":")
|
|
$port = [int]$portPart
|
|
|
|
$modbusCli = Get-CliInvocation `
|
|
-ProjectFolder "src/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Cli" `
|
|
-ExeName "otopcua-modbus-cli"
|
|
$opcUaCli = Get-CliInvocation `
|
|
-ProjectFolder "src/ZB.MOM.WW.OtOpcUa.Client.CLI" `
|
|
-ExeName "otopcua-cli"
|
|
|
|
$commonModbus = @("-h", $hostPart, "-p", $port)
|
|
$results = @()
|
|
|
|
$results += Test-Probe `
|
|
-Cli $modbusCli `
|
|
-ProbeArgs (@("probe") + $commonModbus)
|
|
|
|
$writeValue = Get-Random -Minimum 1 -Maximum 9999
|
|
$results += Test-DriverLoopback `
|
|
-Cli $modbusCli `
|
|
-WriteArgs (@("write") + $commonModbus + @("-r", "HoldingRegisters", "-a", "200", "-t", "UInt16", "-v", $writeValue)) `
|
|
-ReadArgs (@("read") + $commonModbus + @("-r", "HoldingRegisters", "-a", "200", "-t", "UInt16")) `
|
|
-ExpectedValue "$writeValue"
|
|
|
|
$bridgeValue = Get-Random -Minimum 10000 -Maximum 19999
|
|
$results += Test-ServerBridge `
|
|
-DriverCli $modbusCli `
|
|
-DriverWriteArgs (@("write") + $commonModbus + @("-r", "HoldingRegisters", "-a", "200", "-t", "UInt16", "-v", $bridgeValue)) `
|
|
-OpcUaCli $opcUaCli `
|
|
-OpcUaUrl $OpcUaUrl `
|
|
-OpcUaNodeId $BridgeNodeId `
|
|
-ExpectedValue "$bridgeValue"
|
|
|
|
$reverseValue = Get-Random -Minimum 20000 -Maximum 29999
|
|
$results += Test-OpcUaWriteBridge `
|
|
-OpcUaCli $opcUaCli `
|
|
-OpcUaUrl $OpcUaUrl `
|
|
-OpcUaNodeId $BridgeNodeId `
|
|
-DriverCli $modbusCli `
|
|
-DriverReadArgs (@("read") + $commonModbus + @("-r", "HoldingRegisters", "-a", "200", "-t", "UInt16")) `
|
|
-ExpectedValue "$reverseValue"
|
|
|
|
$subValue = Get-Random -Minimum 30000 -Maximum 39999
|
|
$results += Test-SubscribeSeesChange `
|
|
-OpcUaCli $opcUaCli `
|
|
-OpcUaUrl $OpcUaUrl `
|
|
-OpcUaNodeId $BridgeNodeId `
|
|
-DriverCli $modbusCli `
|
|
-DriverWriteArgs (@("write") + $commonModbus + @("-r", "HoldingRegisters", "-a", "200", "-t", "UInt16", "-v", $subValue)) `
|
|
-ExpectedValue "$subValue"
|
|
|
|
Write-Summary -Title "Modbus e2e" -Results $results
|
|
if ($results | Where-Object { -not $_.Passed }) { exit 1 }
|