Files
lmxopcua/tests
Joseph Doherty 50933d57fc feat(heidenhain): PLC/DATA parity with pyLSV2 — FF bits, INPUT/OUTPUT_DWORD, PLCDEBUG write-up
- PLC bit areas (MARKER/INPUT/OUTPUT/COUNTER/TIMER) accept 00/01/FF: real iTNC 530s
  return FF for the same operands over R_DP, and pyLSV2 decodes them as non-zero = true.
  02..FE stay BadDecodingError.
- New PLC:INPUT_DWORD / PLC:OUTPUT_DWORD areas (pyLSV2 MemoryType 13/12): signed
  int32le, element index x 4 over the input/output-word byte pools.
- R_PR offsets agree with pyLSV2. Its count units (BYTE x2, WORD/IW as word counts)
  conflict with the captured controls, so we keep the captures and pin them in a test.
- Docs: pyLSV2 correspondence table, native-operand mapping (no aliases), and why
  raw R_MB is refused (pyLSV2 logs in as the write-capable PLCDEBUG role). That stays
  an owner decision; Lsv2ReadOnlyPolicy is unchanged.

Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk