Joseph Doherty 4de94fab0d Phase 6.1 Stream A remaining — IPerCallHostResolver + DriverNodeManager per-call host dispatch (decision #144)
Closes the per-device isolation gap flagged at the Phase 6.1 Stream A wire-up
(PR #78 used driver.DriverInstanceId as the pipeline host for every call, so
multi-host drivers like Modbus with N PLCs shared one pipeline — one dead PLC
poisoned sibling breakers). Decision #144 requires per-device isolation; this
PR wires it without breaking single-host drivers.

Core.Abstractions:
- IPerCallHostResolver interface. Optional driver capability. Drivers with
  multi-host topology (Modbus across N PLCs, AB CIP across a rack, etc.)
  implement this; single-host drivers (Galaxy, S7 against one PLC, OpcUaClient
  against one remote server) leave it alone. Must be fast + allocation-free
  — called once per tag on the hot path. Unknown refs return empty so dispatch
  falls back to single-host without throwing.

Server/OpcUa/DriverNodeManager:
- Captures `driver as IPerCallHostResolver` at construction alongside the
  existing capability casts.
- New `ResolveHostFor(fullReference)` helper returns either the resolver's
  answer or the driver's DriverInstanceId (single-host fallback). Empty /
  whitespace resolver output also falls back to DriverInstanceId.
- Every dispatch site now passes `ResolveHostFor(fullRef)` to the invoker
  instead of `_driver.DriverInstanceId` — OnReadValue, OnWriteValue, all four
  HistoryRead paths. The HistoryRead Events path tolerates fullRef=null and
  falls back to DriverInstanceId for those cluster-wide event queries.
- Drivers without IPerCallHostResolver observe zero behavioural change:
  every call still keys on DriverInstanceId, same as before.

Tests (4 new PerCallHostResolverDispatchTests, all pass):
- DeadPlc_DoesNotOpenBreaker_For_HealthyPlc_With_Resolver — 2 PLCs behind
  one driver; hammer the dead PLC past its breaker threshold; assert the
  healthy PLC's first call succeeds on its first attempt (decision #144).
- EmptyString / unknown-ref fallback behaviour documented via test.
- WithoutResolver_SameHost_Shares_One_Pipeline — regression guard for the
  single-host pre-existing behaviour.
- WithResolver_TwoHosts_Get_Two_Pipelines — builds the CachedPipelineCount
  assertion to confirm the shared-builder cache keys correctly.

Full solution dotnet test: 1219 passing (was 1215, +4). Pre-existing
Client.CLI Subscribe flake unchanged.

Adoption: Modbus driver (#120 follow-up), AB CIP / AB Legacy / TwinCAT
drivers (also #120) implement the interface and return the per-tag PLC host
string. Single-host drivers stay silent and pay zero cost.

Remaining sub-items of #160 still deferred:
- IAlarmSource.SubscribeAlarmsAsync + AcknowledgeAsync invoker wrapping.
  Non-trivial because alarm subscription is push-based from driver through
  IAlarmConditionSink — the wrap has to happen at the driver-to-server glue
  rather than a synchronous dispatch site.
- Roslyn analyzer asserting every capability-interface call routes through
  CapabilityInvoker. Substantial (separate analyzer project + test harness);
  noise-value ratio favors shipping this post-v2-GA once the coverage is
  known-stable.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 12:31:24 -04:00
..
Phase 3 PR 15 — alarm-condition contract in IAddressSpaceBuilder + wire OnAlarmEvent through GenericDriverNodeManager. IAddressSpaceBuilder.IVariableHandle gains MarkAsAlarmCondition(AlarmConditionInfo) which returns an IAlarmConditionSink. AlarmConditionInfo carries SourceName/InitialSeverity/InitialDescription. Concrete address-space builders (the upcoming PR 16 OPC UA server backend) materialize a sibling AlarmConditionState node on the first call; the sink receives every lifecycle transition the generic node manager forwards. GenericDriverNodeManager gains a CapturingBuilder wrapper that transparently wraps every Folder/Variable call — the wrapper observes MarkAsAlarmCondition calls without participating in materialization, captures the resulting IAlarmConditionSink into an internal source-node-id → sink ConcurrentDictionary keyed by IVariableHandle.FullReference. After DiscoverAsync completes, if the driver implements IAlarmSource the node manager subscribes to OnAlarmEvent and routes every AlarmEventArgs to the sink registered for args.SourceNodeId — unknown source ids are dropped silently (may belong to another driver or to a variable the builder chose not to flag). Dispose unsubscribes the forwarder to prevent dangling invocation-list references across node-manager rebuilds. GalaxyProxyDriver.DiscoverAsync now calls handle.MarkAsAlarmCondition(new AlarmConditionInfo(fullName, AlarmSeverity.Medium, null)) on every attr.IsAlarm=true variable — severity seed is Medium because the live Priority byte arrives through the subsequent GalaxyAlarmEvent stream (which PR 14's GalaxyAlarmTracker now emits); the Admin UI sees the severity update on the first transition. RecordingAddressSpaceBuilder in Driver.Galaxy.E2E gains a RecordedAlarmCondition list + a RecordingSink implementation that captures AlarmEventArgs for test assertion — the E2E parity suite can now verify alarm-condition registration shape in addition to folder/variable shape. Tests (4 new GenericDriverNodeManagerTests): Alarm_events_are_routed_to_the_sink_registered_for_the_matching_source_node_id — 2 alarms registered (Tank.HiHi + Heater.OverTemp), driver raises an event for Tank.HiHi, the Tank.HiHi sink captures the payload, the Heater.OverTemp sink does not (tag-scoped fan-out, not broadcast); Non_alarm_variables_do_not_register_sinks — plain Tank.Level in the same discover is not in TrackedAlarmSources; Unknown_source_node_id_is_dropped_silently — a transition for Unknown.Source doesn't reach any sink + no exception; Dispose_unsubscribes_from_OnAlarmEvent — post-dispose, a transition for a previously-registered tag is no-op because the forwarder detached. InternalsVisibleTo('ZB.MOM.WW.OtOpcUa.Core.Tests') added to Core csproj so TrackedAlarmSources internal property is visible to the test. Full solution: 0 errors, 152 unit tests pass (8 Core + 14 Proxy + 14 Admin + 24 Configuration + 6 Shared + 84 Galaxy.Host + 2 Server). PR 16 will implement the concrete OPC UA address-space builder that materializes AlarmConditionState from this contract.
2026-04-18 07:51:35 -04:00
Phase 1 Streams B–E scaffold + Phase 2 Streams A–C scaffold — 8 new projects with ~70 new tests, all green alongside the 494 v1 IntegrationTests baseline (parity preserved: no v1 tests broken; legacy OtOpcUa.Host untouched). Phase 1 finish: Configuration project (16 entities + 10 enums + DbContext + DesignTimeDbContextFactory + InitialSchema/StoredProcedures/AuthorizationGrants migrations — 8 procs including sp_PublishGeneration with MERGE on ExternalIdReservation per decision #124, sp_RollbackToGeneration cloning rows into a new published generation, sp_ValidateDraft with cross-cluster-namespace + EquipmentUuid-immutability + ZTag/SAPID reservation pre-flight, sp_ComputeGenerationDiff with CHECKSUM-based row signature — plus OtOpcUaNode/OtOpcUaAdmin SQL roles with EXECUTE grants scoped to per-principal-class proc sets and DENY UPDATE/DELETE/INSERT/SELECT on dbo schema); managed DraftValidator covering UNS segment regex, path length, EquipmentUuid immutability across generations, same-cluster namespace binding (decision #122), reservation pre-flight, EquipmentId derivation (decision #125), driver↔namespace compatibility — returning every failing rule in one pass; LiteDB local cache with round-trip + ring pruning + corruption-fast-fail; GenerationApplier with per-entity Added/Removed/Modified diff and dependency-ordered callbacks (namespace → driver → device → equipment → poll-group → tag, Removed before Added); Core project with GenericDriverNodeManager (scaffold for the Phase 2 Galaxy port) and DriverHost lifecycle registry; Server project using Microsoft.Extensions.Hosting BackgroundService replacing TopShelf, with NodeBootstrap that falls back to LiteDB cache when the central DB is unreachable (decision #79); Admin project scaffolded as Blazor Server with Bootstrap 5 sidebar layout, cookie auth, three admin roles (ConfigViewer/ConfigEditor/FleetAdmin), Cluster + Generation services fronting the stored procs. Phase 2 scaffold: Driver.Galaxy.Shared (netstandard2.0) with full MessagePack IPC contract surface — Hello version negotiation, Open/CloseSession, Heartbeat, DiscoverHierarchy + GalaxyObjectInfo/GalaxyAttributeInfo, Read/WriteValues, Subscribe/Unsubscribe/OnDataChange, AlarmSubscribe/Event/Ack, HistoryRead, HostConnectivityStatus, Recycle — plus length-prefixed framing (decision #28) with a 16 MiB cap and thread-safe FrameWriter/FrameReader; Driver.Galaxy.Host (net48) implementing the Tier C cross-cutting protections from driver-stability.md — strict PipeAcl (allow configured server SID only, explicit deny on LocalSystem + Administrators), PipeServer with caller-SID verification via pipe.RunAsClient + WindowsIdentity.GetCurrent and per-process shared-secret Hello, Galaxy-specific MemoryWatchdog (warn at max(1.5×baseline, +200 MB), soft-recycle at max(2×baseline, +200 MB), hard ceiling 1.5 GB, slope ≥5 MB/min over 30-min rolling window), RecyclePolicy (1 soft recycle per hour cap + 03:00 local daily scheduled), PostMortemMmf (1000-entry ring buffer in %ProgramData%\OtOpcUa\driver-postmortem\galaxy.mmf, survives hard crash, readable cross-process), MxAccessHandle : SafeHandle (ReleaseHandle loops Marshal.ReleaseComObject until refcount=0 then calls optional unregister callback), StaPump with responsiveness probe (BlockingCollection dispatcher for Phase 1 — real Win32 GetMessage/DispatchMessage pump slots in with the same semantics when the Galaxy code lift happens), IsExternalInit shim for init setters on .NET 4.8; Driver.Galaxy.Proxy (net10) implementing IDriver + ITagDiscovery forwarding over the IPC channel with MX data-type and security-classification mapping, plus Supervisor pieces — Backoff (5s → 15s → 60s capped, reset-on-stable-run), CircuitBreaker (3 crashes per 5 min opens; 1h → 4h → manual cooldown escalation; sticky alert doesn't auto-clear), HeartbeatMonitor (2s cadence, 3 consecutive misses = host dead per driver-stability.md). Infrastructure: docker SQL Server remapped to host port 14330 to coexist with the native MSSQL14 Galaxy ZB DB instance on 1433; NuGetAuditSuppress applied per-project for two System.Security.Cryptography.Xml advisories that only reach via EF Core Design with PrivateAssets=all (fix ships in 11.0.0-preview); .slnx gains 14 project registrations. Deferred with explicit TODOs in docs/v2/implementation/phase-2-partial-exit-evidence.md: Phase 1 Stream E Admin UI pages (Generations listing + draft-diff-publish, Equipment CRUD with OPC 40010 fields, UNS Areas/Lines tabs, ACLs + permission simulator, Generic JSON config editor, SignalR real-time, Release-Reservation + Merge-Equipment workflows, LDAP login page, AppServer smoke test per decision #142), Phase 2 Stream D (Galaxy MXAccess code lift out of legacy OtOpcUa.Host, dual-service installer, appsettings → DriverConfig migration script, legacy Host deletion — blocked by parity), Phase 2 Stream E (v1 IntegrationTests against v2 topology, Client.CLI walkthrough diff, four 2026-04-13 stability findings regression tests, adversarial review — requires live MXAccess runtime).
2026-04-17 21:35:25 -04:00
Phase 3 PR 60 -- Mitsubishi MELSEC quirk integration tests against mitsubishi pymodbus profile. Seven facts in MitsubishiQuirkTests covering the quirks documented in docs/v2/mitsubishi.md that are testable end-to-end via pymodbus: (1) Mitsubishi_D0_fingerprint_reads_0x1234 -- MELSEC operators reserve D0 as a fingerprint word so Modbus clients can verify they're hitting the right Device Assignment block; test reads HR[0]=0x1234 via DRegisterToHolding('D0') helper. (2) Mitsubishi_Float32_CDAB_decodes_1_5f_from_D100 -- reads HR[100..101] with WordSwap AND BigEndian; asserts WordSwap==1.5f AND BigEndian!=1.5f, proving (a) MELSEC uses CDAB default same as DL260, (b) opposite of S7 ABCD, (c) driver flag is not a no-op. (3) Mitsubishi_D10_is_binary_not_BCD -- reads HR[10]=0x04D2 as Int16 and asserts value 1234 (binary decode), contrasting with DL205's BCD-by-default convention. (4) Mitsubishi_D10_as_BCD_throws_because_nibble_is_non_decimal -- reads same HR[10] as Bcd16 and asserts StatusCode != 0 because nibble 0xD fails BCD validation; proves the BCD decoder fails loud when the tag config is wrong rather than silently returning garbage. (5) Mitsubishi_QLiQR_X210_hex_maps_to_DI_528_reads_ON -- reads FC02 at the MelsecAddress.XInputToDiscrete('X210', Q_L_iQR)-resolved address (=528 decimal) and asserts ON; proves the hex-parsing path end-to-end. (6) Mitsubishi_family_trap_X20_differs_on_Q_vs_FX -- unit-level proof in the integration file so the headline family trap is visible to anyone filtering by Device=Mitsubishi. (7) Mitsubishi_M512_maps_to_coil_512_reads_ON -- reads FC01 at MRelayToCoil('M512')=512 (decimal) and asserts ON; proves the decimal M-relay path. Test fixture pattern: single MitsubishiQuirkTests class with a shared ShouldRun + NewDriverAsync helper rather than per-quirk classes (contrast with DL205's per-quirk splits). MELSEC per-model differentiation is handled by MelsecFamily enum on the helper rather than per-PR -- so one quirk file + one family enum covers Q/L/iQ-R/FX/iQ-F, and a new PLC family just adds an enum case instead of a new test class. 8/8 Mitsubishi integration tests pass (1 smoke + 7 quirk). 176/176 Modbus.Tests unit suite still green. S7 + DL205 integration tests can be run against their respective profiles by swapping MODBUS_SIM_PROFILE and restarting the pymodbus sim -- each family gates on its profile env var so no cross-family test pollution.
2026-04-18 23:07:00 -04:00
Phase 3 PR 76 -- OPC UA Client IHistoryProvider (HistoryRead passthrough). Driver now implements IHistoryProvider (Raw + Processed + AtTime); ReadEventsAsync deliberately inherits the interface default that throws NotSupportedException. ExecuteHistoryReadAsync is the shared wire path: parses the fullReference to NodeId, builds a HistoryReadValueIdCollection with one entry, calls Session.HistoryReadAsync(RequestHeader, ExtensionObject<details>, TimestampsToReturn.Both, releaseContinuationPoints:false, nodesToRead, ct), unwraps r.HistoryData ExtensionObject into the samples list, passes ContinuationPoint through. Each DataValue's upstream StatusCode + SourceTimestamp + ServerTimestamp preserved verbatim per driver-specs.md \u00A78 cascading-quality rule -- this matters especially for historical data where an interpolated / uncertain-quality sample must surface its true severity downstream, not a sanitized Good. SourceTimestamp=DateTime.MinValue guards map to null so downstream clients see 'source unknown' rather than an epoch-zero misread. ReadRawAsync builds ReadRawModifiedDetails with IsReadModified=false (raw, not modified-history), StartTime/EndTime, NumValuesPerNode=maxValuesPerNode, ReturnBounds=false (clients that want bounds request them via continuation handling). ReadProcessedAsync builds ReadProcessedDetails with ProcessingInterval in ms + AggregateType wrapping a single NodeId from MapAggregateToNodeId. MapAggregateToNodeId switches on HistoryAggregateType {Average, Minimum, Maximum, Total, Count} to the standard Part 13 ObjectIds.AggregateFunction_* NodeId -- future aggregate-type additions fail the switch with ArgumentOutOfRangeException so they can't silently slip through with a null NodeId and an opaque server-side BadAggregateNotSupported. ReadAtTimeAsync builds ReadAtTimeDetails with ReqTimes + UseSimpleBounds=true (returns boundary samples when an exact timestamp has no value -- the OPC UA Part 11 default). Malformed NodeId short-circuits to empty result without touching the wire, matching the ReadAsync / WriteAsync pattern. ReadEventsAsync stays at the interface-default NotSupportedException: the OPC UA call path (HistoryReadAsync with ReadEventDetails + EventFilter) needs an EventFilter SelectClauses spec which the current IHistoryProvider.ReadEventsAsync signature doesn't carry. Adding that would be an IHistoryProvider interface widening; out of scope for PR 76. Callers see BadHistoryOperationUnsupported on the OPC UA client which is the documented fallback. Name disambiguation: Core.Abstractions.HistoryReadResult and Opc.Ua.HistoryReadResult both exist; used fully-qualified Core.Abstractions.HistoryReadResult in return types + factory expressions. Shutdown unchanged -- history reads don't create persistent server-side resources, so no cleanup needed beyond the existing Session.CloseAsync. Unit tests (OpcUaClientHistoryTests, 7 facts): MapAggregateToNodeId theory covers all 5 aggregates; MapAggregateToNodeId_rejects_invalid_enum (defense against future enum addition silently passing through); Read{Raw,Processed,AtTime}Async_without_initialize_throws (RequireSession path); ReadEventsAsync_throws_NotSupportedException (locks in the intentional inheritance of the default). 78/78 OpcUaClient.Tests pass (67 prior + 11 new, -4 on the alarm suite moved into the events count). dotnet build clean. Final OPC UA Client capability surface: IDriver + ITagDiscovery + IReadable + IWritable + ISubscribable + IHostConnectivityProbe + IAlarmSource + IHistoryProvider -- 8 of 8 possible capabilities. Driver is feature-complete per driver-specs.md \u00A78.
2026-04-19 02:13:22 -04:00