Files
lmxopcua/tests/Server
Joseph Doherty 5a7a08deca fix(drivers): detect mid-run comms loss and recover from it (#527)
DriverInstanceActor.DisconnectObserved had no production sender. The only paths
into Reconnecting were a failed *initial* connect and an operator's Force
Reconnect, so a driver that connected and then lost its device stayed Connected
indefinitely: publishing Bad for every tag, never re-initialising, and NOT
recovering when the device returned. PublishHealthSnapshot read GetHealth() for
reporting only and never acted on a driver reporting itself unhealthy.

Both comms-loss quality paths -- #477's native-condition annotation and #481's
scripted-alarm input fan-out -- hang off ConnectivityChanged, so both were
correctly wired to a signal that never fired.

The Connected health tick now evaluates a watchdog and self-sends
DisconnectObserved when the driver reports a non-Healthy state AND its
LastSuccessfulRead has been frozen for DefaultCommsLossTimeout (90s).

The conjunction is the design, and the issue's own proposal -- "non-Healthy for
N consecutive polls" -- is wrong. Degraded means *connected but some data is
bad*; several drivers write health per tag inside the read loop
(ModbusDriver.ReadAsync), so one unreadable address latches Degraded forever
against a perfectly reachable device, and a state-only watchdog would reconnect
that driver every 90s indefinitely -- worse than the bug. LastSuccessfulRead is
the honest evidence: preserved across Degraded/Faulted writes, advanced by any
success. The state check remains the second conjunct so an idle Healthy driver
with nothing subscribed is not declared dead for not reading.

Verified across all 12 drivers that a sustained failure does reach a non-Healthy
state -- nine poll drivers via Degraded, MQTT via live connection state, Galaxy
via its reconnect supervisor. CalculationDriver reports Healthy while running
and so can never trip, which is correct: it has no transport.

Also: the Reconnecting retry now calls ShutdownAsync before InitializeAsync.
ModbusDriver (_transport) and MqttDriver (_connection) overwrite an
IAsyncDisposable field inside InitializeAsync without disposing the previous
one, so re-initialising without a teardown leaks a socket per attempt -- latent
while only a manual Force Reconnect reached this path, but the watchdog makes it
automatic and unbounded (~360 leaks for an hour-long outage at the 10s retry).

Tests: 8 new in DriverInstanceActorCommsLossWatchdogTests, each absence
assertion carrying a positive control (a proven count of processed health-poll
ticks). Falsified five ways -- dropping either conjunct reds exactly the test
written for it, and removing the teardown, the null baseline, or the watchdog
call each reds its own guard.

Live gate PASSED on docker-dev (Modbus + otopcua-pymodbus-standard), run twice:
  - fixture stopped -> watchdog fires at ~108s, "declaring comms lost"
  - fan-out observed at Debug: "pushed BadNoCommunication for 2 mux ref(s)"
    (#481 Layer 4) and the #477 native-condition annotation on a driver
    owning conditions
  - fixture restarted -> reconnected in ~8s with NO node restart; both the raw
    (ns=2) and UNS (ns=3) NodeIds read Good with fresh timestamps

Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
2026-07-31 10:58:38 -04:00
..