lmxopcua/tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/DL205/DL205SmokeTests.cs
Joseph Doherty cb7b81a87a Phase 3 PR 30 — Modbus integration-test project scaffold. New tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests project is the harness modbus-test-plan.md called for: a skip-when-unreachable fixture that TCP-probes a Modbus simulator endpoint (MODBUS_SIM_ENDPOINT, default localhost:502) once per test session, a DL205 device profile stub (single writable holding register at address 100, probe disabled to avoid racing with assertions), and one happy-path smoke test that initializes the real ModbusDriver + real ModbusTcpTransport, writes a known Int16 value, reads it back, and asserts status=0 + value round-trip. No DL205 quirk assertions yet — those land one-per-PR as the user validates each behavior in ModbusPal (word order for 32-bit, register-zero access, coil addressing base, max registers per FC03, response framing under load, exception code on protected-bit coil write).
ModbusSimulatorFixture is a collection fixture so the 2s TCP probe runs once per run, not per test; SkipReason gets a clear operator-facing message ('start ModbusPal or override MODBUS_SIM_ENDPOINT'). Tests call Assert.Skip(sim.SkipReason) rather than silently returning — matches the test-plan convention and reads cleanly in CI logs. DL205Profile.BuildOptions deliberately disables the background probe loop since integration tests drive reads explicitly and the probe would race with assertions. Tag naming uses the DL205_ prefix so filter 'DisplayName~DL205' surfaces device-specific failures at a glance.
Project references: xunit.v3 + Shouldly + Microsoft.NET.Test.Sdk + xunit.runner.visualstudio (matches the existing Driver.Modbus.Tests unit project), project ref to src/Driver.Modbus. Registered in ZB.MOM.WW.OtOpcUa.slnx under tests/. ModbusPal/README.md documents the dev loop (install ModbusPal jar, load profile, start simulator, dotnet test), explains MODBUS_SIM_ENDPOINT override for real-PLC benchwork, and flags DL205.xmpp as the first profile to add in a follow-up PR.
dotnet test run against the scaffold (no simulator running) skips cleanly: 0 failed, 0 passed, 1 skipped, with the SkipReason surfaced. dotnet build clean (0 warnings, 0 errors). Updated docs/v2/modbus-test-plan.md to mark the scaffold PR done and renumbered future PRs from 'PR 27+' to 'PR 31+' to stay in sync with the actual PR chain.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-18 15:02:39 -04:00

54 lines
2.6 KiB
C#

using Shouldly;
using Xunit;
using ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests;
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests.DL205;
/// <summary>
/// End-to-end smoke against the DL205 ModbusPal profile (or a real DL205 when
/// <c>MODBUS_SIM_ENDPOINT</c> points at one). Drives the full <see cref="ModbusDriver"/>
/// + real <see cref="ModbusTcpTransport"/> stack — no fake transport. Success proves the
/// driver can initialize against the simulator, write a known value, and read it back
/// with the correct status and value, which is the baseline every device-quirk test
/// builds on.
/// </summary>
/// <remarks>
/// Device-specific quirk tests (word order, max-register, register-zero access, exception
/// code translation, etc.) land as separate test classes in this directory as each quirk
/// is validated in ModbusPal. Keep this smoke test deliberately narrow — any deviation
/// the driver hits beyond "happy-path FC16 + FC03 round-trip" belongs in its own named
/// test so filtering by device class (<c>--filter DisplayName~DL205</c>) surfaces the
/// quirk-specific failure mode.
/// </remarks>
[Collection(ModbusSimulatorCollection.Name)]
[Trait("Category", "Integration")]
[Trait("Device", "DL205")]
public sealed class DL205SmokeTests(ModbusSimulatorFixture sim)
{
[Fact]
public async Task DL205_roundtrip_write_then_read_of_holding_register()
{
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
var options = DL205Profile.BuildOptions(sim.Host, sim.Port);
await using var driver = new ModbusDriver(options, driverInstanceId: "dl205-smoke");
await driver.InitializeAsync(driverConfigJson: "{}", TestContext.Current.CancellationToken);
// Write first so the test is self-contained — ModbusPal's default register bank is
// zeroed at simulator start, and tests must not depend on prior-test state per the
// test-plan conventions.
var writeResults = await driver.WriteAsync(
[new(FullReference: "DL205_Smoke_HReg100", Value: (short)DL205Profile.SmokeHoldingValue)],
TestContext.Current.CancellationToken);
writeResults.Count.ShouldBe(1);
writeResults[0].StatusCode.ShouldBe(0u, "write must succeed against the ModbusPal DL205 profile");
var readResults = await driver.ReadAsync(
["DL205_Smoke_HReg100"],
TestContext.Current.CancellationToken);
readResults.Count.ShouldBe(1);
readResults[0].StatusCode.ShouldBe(0u);
readResults[0].Value.ShouldBe((short)DL205Profile.SmokeHoldingValue);
}
}