Phase 3 PR 48 -- DL205 CDAB word order for Float32 end-to-end test. The driver has supported ModbusByteOrder.WordSwap (CDAB) since PR 24 for all multi-register types -- the underlying word-swap code path was already there. PR 48 closes the loop with an integration test that validates it end-to-end against the dl205 pymodbus profile: HR[1056..1057] stores IEEE-754 1.5f with the low word at the lower address (0x0000 at HR[1056], 0x3FC0 at HR[1057]). Reading with WordSwap returns 1.5f; reading with BigEndian returns a tiny denormal (~5.74e-41) -- a silent "value is 0" bug that typically surfaces in the field only when an operator notices a setpoint readout stuck at 0 while the PLC display shows the real value. Test asserts both: WordSwap==1.5f AND BigEndian!=1.5f, proving the flag is not a no-op. No driver code changes -- the word-swap normalization at NormalizeWordOrder() has handled Float32/Int32/UInt32 correctly since PR 24 and the unit test suite already covers it (Int32_WordSwap_decodes_CDAB_layout + Float32 equivalent). This PR exists primarily to lock in the integration-level validation so future refactors of the codec don't silently break DL205/DL260 floats. 6/6 DL205 integration tests pass with MODBUS_SIM_PROFILE=dl205.
2026-04-18 21:51:15 -04:00
..
DL205
Phase 3 PR 48 -- DL205 CDAB word order for Float32 end-to-end test. The driver has supported ModbusByteOrder.WordSwap (CDAB) since PR 24 for all multi-register types -- the underlying word-swap code path was already there. PR 48 closes the loop with an integration test that validates it end-to-end against the dl205 pymodbus profile: HR[1056..1057] stores IEEE-754 1.5f with the low word at the lower address (0x0000 at HR[1056], 0x3FC0 at HR[1057]). Reading with WordSwap returns 1.5f; reading with BigEndian returns a tiny denormal (~5.74e-41) -- a silent "value is 0" bug that typically surfaces in the field only when an operator notices a setpoint readout stuck at 0 while the PLC display shows the real value. Test asserts both: WordSwap==1.5f AND BigEndian!=1.5f, proving the flag is not a no-op. No driver code changes -- the word-swap normalization at NormalizeWordOrder() has handled Float32/Int32/UInt32 correctly since PR 24 and the unit test suite already covers it (Int32_WordSwap_decodes_CDAB_layout + Float32 equivalent). This PR exists primarily to lock in the integration-level validation so future refactors of the codec don't silently break DL205/DL260 floats. 6/6 DL205 integration tests pass with MODBUS_SIM_PROFILE=dl205.
2026-04-18 21:51:15 -04:00
Pymodbus
Phase 3 PR 43 — followup commit: validate pymodbus simulator end-to-end + fix three real bugs surfaced by running it. winget-installed Python 3.12.10 + pip-installed pymodbus[simulator]==3.13.0 on the dev box; both profiles boot cleanly, the integration-suite smoke test passes against either profile.
2026-04-18 21:14:02 -04:00
ModbusSimulatorFixture.cs
Phase 3 PR 43 — followup commit: validate pymodbus simulator end-to-end + fix three real bugs surfaced by running it. winget-installed Python 3.12.10 + pip-installed pymodbus[simulator]==3.13.0 on the dev box; both profiles boot cleanly, the integration-suite smoke test passes against either profile.
2026-04-18 21:14:02 -04:00
ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests.csproj
Phase 3 PR 43 — Swap ModbusPal to pymodbus for the integration-test simulator. Replaces the .xmpp profiles shipped in PR 42 with pymodbus 3.13.0 ModbusSimulatorServer JSON configs in tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/Pymodbus/. Substantive reasons for the swap (rationale block in the test-plan doc): ModbusPal 1.6b is abandoned (last release ~2019), Java GUI-only with no headless mode in the official JAR, and only exposes 2 of the 4 standard Modbus tables (holding_registers + coils — no input_registers, no discrete_inputs). pymodbus is current stable, pure Python CLI (pip install pymodbus[simulator]==3.13.0), exposes all four tables, has built-in declarative actions (increment / random / timestamp / uptime) for dynamic registers, supports custom Python actions for anything more complex, and ships an optional aiohttp-based web UI / REST API for live inspection. Pip-installable on Windows; sidesteps the privileged-port admin requirement by defaulting to TCP 5020.