Files
lmxopcua/src
Joseph Doherty 44a03bedc0 fix(historian): #685 Gateway native TimeAverage/Total — drop AVEVA's pre-window row, keep Uncertain values
AVEVA answers one extra row for the interval before the window; it was mapped as
a result stamped before StartTime (N+1 values). Rows whose interval lies outside
the requested span (either direction) are now dropped after the drained stream.
An Uncertain (opc 64-191) interval kept no value (opc >= 192 was the only data
test); it now carries its value as UncertainDataSubNormal | Calculated.
Docs: AVEVA's TWA excludes NULL-gap time while the SQL backends bridge it;
end-to-end per-interval values also need historiangw#27.
2026-10-12 15:14:56 -04:00
..